Thermocouple Calibrators
-
Product
Temperature Calibrators
-
Fluke Temperature Calibrators simulate process sensors for testing temperature instrumentation. Specifically designed for the field, these lightweight compact tools are EMI tolerant, dust and splash resistant and offer an easy to use single push button interface. When paired with a temperature sensor they can take high accuracy temperature measurements to verify process temperatures and ensure the highest product quality and safety. There are a variety of different temperature calibrators designed for your unique calibration and testing requirements.
-
Product
Tool, Locator, Thermocouple, Receiver
910104134
Locator Tool
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
Product
Calibrators
-
Portable and user friendly calibrator, ideal for checking sound level meters and dosimeters on the measurement site, or in the laboratory.
-
Product
MAX31855 K-Type Thermocouple Sensor Breakout
SEN-30003-K
-
Breakout board for the MAX31855K digital thermocouple interface ICs by Maxim. Measured temperature range is -270C-1372C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 2x5 pin header (8-pins used), has four vertical mini thermocouple connectors and four mounting holes for standoffs and 4-40 screws.
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
AC Power Calibrator
LS3300
-
The LS3300 is an AC signal generator capable of outputting both current and voltage simultaneously, thus allowing it to calibrate power meters. Providing output ranges of 10mV-1250V, and 0.3 mA to 62.5 A, and upto 78.125 kW, the unit is capable of calibrating up to 0.15 % Class Power meters. New features on the LS3300 include a high definition LCD display, a vector diagram, and the ability to synchronize up to three units to emulate anything from single phase two wire to three phase four wire systems.
-
Product
Calibrated Pocket Magnetometer
M 25
-
Instruments available in 8 different, Full Scale, Gauss Ranges.
-
Product
Gauge Type T Thermocouple Wire
W-TW-26
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Calibration
-
Formal quality systems, such as those described in ISO 9000, require gauges to be properly controlled, logged and in calibration. Increasingly, users are specifying that the readings taken by gauges are traceable to National Standards. There are three types of coating thickness standards available from Elcometer: calibration foils, coated standards and zero test plates.
-
Product
Ice Point Calibrators
-
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
Product
MAX31855 T-Type Thermocouple Sensor Breakout
SEN-30001-T
-
Breakout board for the MAX31855T digital thermocouple interface IC. Measured temperature range is -270C-400C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header, has a vertical mini thermocouple connector and four mounting holes for standoffs and 4-40 screws.
-
Product
Calibration
-
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
Product
8 Channels Thermocouple, LV A/D
TC1
-
A thermocouple is a temperature-measuring device typically consisting of two dissimilar conductors that contact each other at one or more spots. It produces a voltage when the temperature of one of the spots differs from the reference temperature on other parts of the circuit. Thermocouple temperature sensors are widely used for measurement and control, and can also convert a temperature gradient into electricity.
-
Product
Eight-channel USB Voltage and Thermocouple DAQ
Model DI-2008
-
Includes DI-2008 instrument, WinDaq software, calibration certificate, terminal screwdriver, and USB cable (6-feet). Eight differential and isolated analog input channels. Seven bi-directional digital input ports, including: Counter input for totalizing applications, Rate input for frequency/flow/rpm applications. ChannelStretch™ channel expansion to 128 analog and 112 digital channels. Programmable voltage and thermocouple measurements per channel. 10 mV to 50 V programmable range per channel in 12 steps.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
Thermometer Calibration
-
In addition to the vast array of Thermometers that Comark has an offer, We also offer a range of devices to assist you with Thermometer Calibration.
-
Product
Thermocouple Power Sensors
N8481H
Power Sensor
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
Product
Thermocouple Vane Probe
AP472S1
-
Vane probe with K type thermocouple ∅ 100 mm to measure air speed in the range 0.6…25 m/s and air temperature in the range –25°C … +80°C.
-
Product
V/mA Process Calibrator
Model KM-CAL-907
-
Kusam Electrical Industries Limited
This is a source and measure type of calibrator and it gives high accuracy of 0.02% . It has dual display. 5 digits display for measure and 6 digits display for source & white LED for backlight.
-
Product
Transducer Calibration
m+p SensCal
-
Regular transducer calibration is an essential requirement for maintaining the accuracy, reliability and repeatability of the results obtained from a measurement system. m+p international’s m+p SensCal program provides a quick and simple process for calibrating accelerometers (piezo-electric with charge output or IEPE, piezo-resistive, capacitive) in your laboratory, as well as velocity or displacement transducers.
-
Product
Calibration Gas
-
Cambridge Sensotec supplies bespoke gas calibration kits for our O2 and SF6 gas analysers, as well our gas detection & MAP product ranges. Each kit has the appropriate calibration gases and flow regulator supplied in a convenient carry/storage case.
-
Product
Micro-Ohmmeter Calibration Kit
LOM-530
-
The LOM-530 is convenient single unit containing a complete set of (5) working standard grade resistors for complete calibration of micro-ohmmeters. The standard resistance values are those used by the LOM-510A Microohmmeter/Milliohmmeter.
-
Product
Electrical Calibration
-
All calibrations include as Found/as Left data, Measurement Uncertainity, Calibration Sticker, Calibration Certificate and online access to calibration data at NO additional charge.
-
Product
Thermocouple Switchbox
SWT-2
-
The SWT-2 is a compact, economical switchbox that lets you use two probes in a thermometer which has a single input. SWT-2 was designed with our BAT-12 Thermometer in mind - it is small and easy to carry in the field with a portable BAT-12 - but it also fits any miniature Type T socket. A subminiature connector mates quickly and easily to most Type T thermometers.
-
Product
Calibrator
-
Shijiazhuang Suin Instruments Co., Ltd.
Is a device used to adjust an instrument accuracy,
-
Product
Calibrator for Battery Charger-Analyzers
VCM-100
-
The VCM 100 is an instrument designed to verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium, Lead-Acid and other types of batteries.
-
Product
Frequency Calibrator
VCH-313
-
The frequency calibrator VCH-313 is designed to determine the frequency error and calibrate frequency standards of various types based on the signals of the NSC SNS GLONASS/GPS .
-
Product
Gauges & Calibrators
-
Ralston Instruments' gauges and calibrators are born from decades of experience working with technicians, project managers and facilities teams responsible for maintaining metrology instruments.
-
Product
Temperature Calibration
-
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.





























