Thermocouple Calibrators
-
Product
Two Inputs Thermocouple Thermometer
HD2328.0
-
Thermocouple thermometer for probes type K, J, T, E. It measures temperature by means of immersion, penetration, contact or aria probes. Two inputs for miniature thermocouple connectors. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree.
-
Product
Acoustic Calibration
-
Trescal provides full Acoustic Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Acoustic Calibration services can be delivered at your site or at our lab. Accreditations for our acoustic calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
PD Calibrator
-
PDCAL has excellent pulse-with stability; scale calibration factors are permanently stored inside its flash memory. Thanks to on board photo coupler PDCAL output pulse can be synchronized with the actual line frequency through external surrounding electrical light source systems.
-
Product
Manual Pressure Calibration
-
Manual pressure calibrators are a fast and practical solution for generating and adjusting pressure while calibrating analog pressure gauges and other sensors. They are convenient for mobile calibration applications. Fluke Calibration's pressure monitors combine very high accuracy measurement capability and a variety of unique features in compact and easy to use packages, either standalone or integrated with a calibrator. Models include E-DWT DHI electronic deadweight testers; RPM4 DHI pressure monitors and 7050 Ruska pressure monitors.
-
Product
Temperature Calibrators
-
Ensuring process temperature accuracy involves calibrating not only the system’s electronic temperature signals, but also the very temperature sensors that initiate those signals. Rugged Fluke handheld temperature calibrators source and measure RTDs and thermocouples, power transmitters, and store data. Fluke Calibration temperature sources cover temperatures from -45 °C to 1200 °C and include handheld, portable, and benchtop calibrators. Infrared thermometer calibrators and reference measurement thermometers ensure every necessary tool is available to you.
-
Product
Cryostat Calibrators
-
Electronic Development Labs, Inc.
Specialized, low-temperature, passively cooled, or liquid nitrogen-based apparatuses designed to calibrate temperature sensors (RTDs, thermocouples, PRTs) at cryogenic levels.
-
Product
Humidity Calibration
-
Trescal provides full Humidity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Humidity Calibration services can be delivered at your site or at our lab. Accreditations for our humidity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
Electronic Calibration Module
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
Product
Exhaust Gas Temperature Thermocouple
LM6000 T4.8
-
The latest and most capable LM6000 gas turbine exhaust gas temperature (EGT) probe from AMETEK offers the longest possible life. AMETEK is the original EGT probe supplier for CF6 aircraft engines. LM2500, LM5000, and LM6000 industrial gas turbines and now brings to market an EGT probe with new materials and a new design. The latest LM6000 T4.8 EGT thermocouple is OEM qualified and incorporates, many improvements over any previous products. Materials are carefully selected to ensure long product life and superior performance. Specifically, a new single crystal alloy for the probe support significantly improves high temperature mechanical strength. In addition, the thermocouple sheath material increases high temperature oxidation and creep resistance. Best of all, AMETEK's new T4.8 thermocouple is completely interchangeable so that it can be used on all LM6000 applications.
-
Product
Multi Function Calibrators
-
This range of multi function calibrators are designed for accurately simulating various sensor values such as temperature, voltage and current for calibration purposes.
-
Product
Temperature Calibration Software v5.1
MET/TEMP II
-
MET/TEMP II software allows you to easily automate the calibration of a wide range of temperature sensors. It provides a comprehensive temperature calibration solution that allows you to test large quantities of sensors, calculate characterization coefficients, and print calibration reports. You can standardize comparison or fixed point calibrations and use multiple temperature sources or references in one test.
-
Product
Multifunction Process Calibrators
-
Practical Instrument Electronics, Inc.
Tired of carrying large, cumbersome multifunction calibrators with their confusing buttons and menus? PIE multifunction calibrators are small, easy to use and extremely accurate. The unique and intuitive EZ-DIAL Double Click Menu makes them simpler to setup than larger calibrators with their complicated button filled panels and confusing menus. Use PIE right out of the box instead of wasting time learning to use more complex calibrators. PIE has a multifunction calibrator to fit your needs from the PIE 820 with a single display to the advanced troubleshooting capabilities of the PIE 830.
-
Product
Thermocouple Extension Lead
EXT-6
-
The EXT-6 - 6 foot, Type T Thermocouple Extension Lead. Flexible vinyl covered.
-
Product
Meter Test & Calibration
-
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of products for meter test and calibration including portable power source, standard reference meter and meter test system. All products are accredited to the highest production standards with different options of measurement accuracy (class 0.05 and class 0.1).These enable them to cover different applications for test and calibration of different types of energy meters, electric transducers, indicating meters and so on.
-
Product
Microwave Measurements & VNA Calibrations
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
For microwave measurements and VNA calibrations, Rosenberger develops, manufactures, and provides test & measurement products which meet the highest demands of industrial test applications. These include high-performance VNA test cableswith outstanding phase and amplitude stability, a variety of test port adaptors for VNA applications up to 110 GHz, very robust interchangeable high mating cycle port connector systems, and test devices – from low-frequency devices for simple measurements to components permitting high-precision broadband measurements.
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-K
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.
-
Product
SparkFun Thermocouple Breakout
MAX31855K
-
The SparkFun MAX31855K Thermocouple Breakout is a simple 14-bit resolution, SPI-compatible, serial interface thermocouple digitizer that makes reading a wide range of temperatures possible. A thermocouple works by taking two wires made of dissimilar metals, connecting them at the two ends, and making a temperature gradient between one end and the other (a 'hot' end and a 'cold' one). Once this is achieved, a voltage potential is formed and current flows. The SparkFun Thermocouple Breakout takes a standard Type-K thermocouple in one end, digitizes the temperature measured and sends that data out the other end via a SPI interface, thereby interpreting the data and translating it for you to read!
-
Product
Calibration
EMC Test Antennas
-
There are some changes in the calibration standard ANSI C63.4 concerning the calibration procedures of hybrid antennas, also the newly issued standard - CISPR 16-1-6 dealing with EMC antenna calibration is covered by our services. You are very welcome to consult Seibersdorf Laboratories calibration experts for the recommended calibration procedures of the most common radiated emission test standards.
-
Product
Precision Sound Level Calibrator
CAL200
-
The Larson Davis CAL200 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
Product
MAX31855 K-Type Thermocouple Sensor Breakout
SEN-30001-KDP
-
Breakout board for the MAX31855K digital thermocouple interface IC. Measured temperature range is -270C-1372C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header and four mounting holes for standoffs and 4-40 screws. It does not contain a mini thermocouple connector.
-
Product
Calibration Test Pumps
-
High-precision calibration & pressure testing is the key to success in the oil & gas, petrochemical, maritime, pharmaceutical and aerospace industries and the right calibration tools make all the difference. Ralston Instruments offers a wide array of intelligently designed, high-quality calibration test pumps that simplify complex calibration processes while providing fast, accurate results. All Ralston pressure test pumps are lightweight, extremely durable, and easy to disassemble and repair with standard hand tools. And for quick connectivity with the most effective results, they all come with Ralston Quick-test™ adapters for safe, stable, leak-free connections without the need for a wrench or thread tape.
-
Product
Electrical Calibration
-
We offer electrical calibration on a wide range of instruments covering all brands and types of electrical testers. Being the only calibration company in Ireland to have Fluke's state of the art 5320a Multi-product calibrators allows us to match or in many cases exceed the manufactures calibration such as Fluke, Megger, Kewtech etc, but for a lot less cost and downtime to you.
-
Product
Relative Humidity Calibration Services
-
PST have calibration laboratories offering Relative Humidity calibrations in six locations across the globe.
-
Product
Pressure Test & Calibration Pumps
-
Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 1,500psi (100bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 918 is an ideal comparison test pump for pressure instruments calibration.
-
Product
Gauge Type T Thermocouple Wire
W-TW-36P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
High Current Calibrator
MC151
-
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
Product
7-Ch Thermocouple Input Module
ADAM-5018
-
Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 HzSampling Rate: 10 samples/sec. (total)High Common Mode: 2000 VDCIsolation Voltage: 3,000 VDCFault and Overvoltage Protection: Withstands over voltage up to ±35 VCMR @ 50/60 Hz: 92 dB minInput Impedance: 20 MΩ. (Build-in 120 Ω Register for Current Input)Built-in TVS/ESD ProtectionFilter function: Yes
-
Product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
-
Portable, self-contained, high-intensity acoustic microphone calibration source