Thermocouple Calibrators
-
Product
Two-way Wireless Thermocouple Temperature Data Logger with LCD
RFTCTemp2000A
-
The RFTCTemp2000A is two-way Wireless thermocouple based temperature data logger with LCD. Transmits up to 2000' maximum (outdoors unobstructed). Built-in memory also stores data internally. Features a built-in temperature sensor for cold junction compensation (CJC). An external thermocouple probe is required (not included). Accepts J, K, T, E, R, S, B, and N type thermocouples.
-
Product
Calibration Kit
S2611
-
*S2611 Calibration Kit, * Frequency Range: up to 26.5 GHz, * Impedance: 50 Ohm, * Connector type: 3.5 mm female.
-
Product
Mineral Insulated Thermocouples IEC
-
Durable Mineral Insulated type thermocouples to suit a wide range of temperature measurement. Various probe types, lengths and diameters available.
-
Product
PC Programmable, Suitable For Thermocouple Sensors
SEM206TC
-
The SEM206/TC is our entry level PC programmable temperature transmitter
-
Product
MAX31855 J-Type Thermocouple Sensor Breakout
SEN-30003-J
-
Breakout board for the MAX31855J digital thermocouple interface ICs by Maxim. Measured temperature range is -210C-1200C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 2x5 pin header (8-pins used), has four vertical mini thermocouple connectors and four mounting holes for standoffs and 4-40 screws. The SEN-30003 is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance (many other level shifters reduce data rates to below 500 kHz).
-
Product
Air Pollution Multigas Calibrator
APMC-370
-
Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.
-
Product
Temperature Calibrators
-
AMETEK Sensors, Test & Calibration
Our dry-block and liquid bath temperature calibrators include 6 series with more than 25 models and temperature ranges from -100 to 1205°C. All feature portability, accuracy, speed, and advanced documenting functions with JofraCal calibration software. Our calibrators include the smallest and coldest dry-block calibrators available.
-
Product
Precision Sound Level Calibrator
CAL200
-
The Larson Davis CAL200 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
Product
K Thermocouple Penetration Probe
TP758
-
"K" Type thermocouple penetration probe. °C max: 400. Response time: 4 s.
-
Product
Signal/Thermocouple, Module, Receiver, TriPaddle/ Thermocouple, 84/12 Position
510104261
Receiver Module
Signal/Thermocouple, Module, Receiver, TriPaddle/ Thermocouple, 84/12 Position
-
Product
K Thermocouple Immersion Probe
TP651_TP652
-
Immersion "K" Type thermocouple probe. °C max: 1200. Response time: 6 s.
-
Product
K-type Thermocouple to Digital Converter
THERMO K click
-
THERMO K click carries the MCP9600 IC from Microchip. Depending on the type of probe it uses the click can measure temperatures from −200 °C to +1372 °C.
-
Product
Portable Calibration Baths
6109A / 7109A
-
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
-
Product
Test Equipment Calibration
-
EMC Technologies can provide convenient, local, NATA accredited calibration services which greatly reduces lead time and costs for EMC test equipment. In the past these items had to be sent overseas or to expensive government laboratories. We can calibrate these items against common standards such as CISPR 16 (and subparts), IEC 61000-6-X series, ANSI C63.4, ANSI C63.5 and ARP 958.
-
Product
AC Calibration Standard
1U647-001
-
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
Product
Calibration Hand Pumps
-
Nagman Instruments & Electronics Pvt. Ltd
Calibration hand pumps are the most cost-effective way to calibrate pressure devices. At Nagman, you can find Calibration hand pumps that are the best in the industry. Calibration hand pumps are used to generate pressure. Which can be hydraulic, pneumatic, or vacuum. This kind of pressure generation is done during testing and calibration applications. We also offer calibration pumps that can help in high pressure to low pressure calibrations. Visit Nagman website and browse through the range of calibration hand pumps to find the right device for your calibration needs.
-
Product
Light Meter Calibration Services
-
International Light Technologies
International Light has been offering light meter calibration services since we created the first USA-made light measurement system in 1965. Our full service calibration lab offers ISO 17025 Accredited (UKAS recognized) calibrations and certifications that are also N.I.S.T. Traceable.
-
Product
HiPot Calibrator
Model 9102
-
The 9102 Hipot Calibrators is specially designed standard devices for instrument calibration lab. The 9102 can simulate multiple loads and apply to various Hipot testers. These calibration equipment can save manufacturers a great deal of regular calibration fee.
-
Product
Exhaust Gas Thermocouples
8TR4C Series
-
The AMETEK 8TR4C Series Exhaust Gas Thermocouples for Frame 7 and 9 applications have been designed, fully tested, and qualified to meet OEM specifications. AMETEK has worked closely with the OEM turbine manufacturer to qualify and engine test this thermocouple as a direct replacement, or for upgrading older style Exhaust Gas Thermocouples.
-
Product
AC Power Calibrator
LS3300
-
The LS3300 is an AC signal generator capable of outputting both current and voltage simultaneously, thus allowing it to calibrate power meters. Providing output ranges of 10mV-1250V, and 0.3 mA to 62.5 A, and upto 78.125 kW, the unit is capable of calibrating up to 0.15 % Class Power meters. New features on the LS3300 include a high definition LCD display, a vector diagram, and the ability to synchronize up to three units to emulate anything from single phase two wire to three phase four wire systems.
-
Product
VR/AR/MR Calibration Platform
Test Platform
AR, VR and MR device calibration is critical for product performance. Leverage Averna’s standardized alignment platform to efficiently calibrate cameras and Inertial Measurement Unit (IMU) modules with supreme accuracy. Easily customize or upgrade the base platform into the automated quality solution to best fit your manufacturing requirements.
-
Product
Process Calibrators
-
4-20mA Process calibrators are specific equipment which, thanks to the employed modern building technology, is now part of the range of mobile devices which have become indispensable to technicians working on modern installations.
-
Product
Thermocouple (J-Type) And Temperature Probe Adapter
U1185A
-
The U1185A consists of a thermocouple bead (J-type) and a mini connector to dual banana plugs.
-
Product
Phase Noise Generator / Calibrator
PNG-A
-
Noise eXtended Technologies S.A.S.
The PNG-A is a high precision generator used in Test and Measurement instruments calibration. It is a Signal Generator with precisely computed phase and amplitude noise characteristics. With its wide frequency offset range, 1Hz to 1 MHz offset, and its programmable Phase and Amplitude noise in real time, this is the ideal standard to calibrate phase noise analyzers, Signal Source Analyzers and Spectrum Analyzers.
-
Product
Pressure Test & Calibration Pumps
-
Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 1,500psi (100bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 918 is an ideal comparison test pump for pressure instruments calibration.
-
Product
30:1 Spot IR Thermometer with Type K Thermocouple
FLIR TG56
-
The FLIR TG56 provides non-contact surface temperature readings so you can quickly and easily take measurements in places that are out of reach. Providing a distance-to-spot ratio of 30:1, the TG56 can measure smaller targets from a safer distance. The thermometer gives you control to view your current reading and last two temperature readings simultaneously, and the color screen makes it easy to navigate and select settings.
-
Product
Seismic Transducers Calibration System
-
Calibration of the seismic sensors should be conducted in the low-frequency domain, which means, that the relative method used for calibration of the vibration transducers is not applicable since it does not guarantee the required accuracy level. The problem is that the reference accelerometers have uneven AFR characteristic in the low-frequency domain. Thus, calibration of seismic transducers requires implementation of a different approach.
-
Product
Velocity Calibration
-
Trescal provides full Velocity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Velocity Calibration services can be delivered at your site or at our lab. Accreditations for our velocity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Temperature Calibration Equipment
-
We offer wide line of temperature calibration equipment for calibration of contact type sensors (Baths/furnaces) and non contact type sensors (Black Bodies), available in temperature range -80°C to 1700°C.





























