Thermocouple Calibrators
-
Product
Three-Phase Electric Power/Energy Calibrator
MC133Ci
-
The MC133Ci model is a compact one-housing three phase electric power/energy calibrator. It can supply the device under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A.
-
Product
Acceleration Pickup Calibrator
VX-1100A
-
VX-1100 is for a piezoelectric type accelerometer which is widely used for measuring vibration. This compact calibrator is effective for checking operation(sensitivity) sensors before measurement to acquire accurate data.Built-in sensor amplifier and display in one unit allows direct reading of the sensitivity. This calibrator excites the sensor at a frequency of 159 Hz and acceleration of 10 m/s2 rms, and the sensor outputs can be used as calibration signals for a vibration measuring system.
-
Product
MAX31855 T-Type Thermocouple Arduino Shield
SEN-30004-T03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino.Each order comes with one board and a set of four female, long extension, headers that can be soldered to the board. If stacking two of these modules on top of each other, please order both a Ch 0-3 and a Ch 4-7 board, as well as an additional set of headers for stacking. We're working on sourcing even longer headers, but the ones currently available are not long enough to stack as-is (they need to be double-stacked).The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or MegaNote: we also offer a universal version of this board in a smaller for factor, the SEN-30003-T.FeaturesType-specific, miniature-sized vertical thermocouple connectors (vertical flat blades, see pics)Measures four (4) thermocouple channels, full extended range.Boards are stackable. Up to 8 thermocouple channels may be connected to an Arduino.14-bit SPI interfacePlugs directly into an Arduino Uno or Mega form factor with built-in voltage level translation on-board.Standard Arduino female headers required for easy configuration, one set included with order (1-6x1, 2-8x1, 1-10x1 0.1" female stackable headers), not soldered on.Detects shorts to GND or VccDetects open thermocoupleOther versions available (K, J, and T stocked). Contact Customer Service to place a custom order.Mounting holes for 4-40 sized screwsConnections are spaced for 0.1" pin headerDesigned, manufactured, tested and shipped from the USA The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
RH Calibrator / Dew Point Generator
-
Edgetech Instruments'' portable calibration system offers the highest accuracy available for both relative humidity and temperature. Using chill mirror technology and precision PRT's, Edgetech''s calibrators offer best repeatability, stability and reliability when measuring RH and temperature. The calibrators are used mainly by calibration labs as a reference standard.The Edgetech Instruments dew point generator, DewGen, another calibration lab favorite, can be used as a stand alone or with a NIST traceable chill mirror dew point system creating very accurate dew points or frost points. Depending on the dry gas source this generator can create dew points from +15C to -80C.
-
Product
Network Analyzer N-Port Calibrated Measurements
S95551B
Network Analyzer
PXI vector network analyzers (VNA) offer the capability to extend the number of ports for your measurements by using additional modules. When multiple modules are used, they are configured for multiport operation. The S95551B adds a multiport analyzer mode that enables full multiport error correction and measurement capabilities. The instruments may be identified as one VNA by the firmware running on an external host PC. At least one VNA instrument connected to your PC must have one S95551B license to maintain N-port capabilities.
-
Product
Calibration Services
-
WTG's calibration package is more than just verification of performance specs. It is a complete package of services including inspection and maintenance. Our services uphold the value of the instrument and extend its lifetime.
-
Product
RF Calibration Kit
SMK-3000
-
The SMK calibration kits are precision, high power calibration standards that are used to calibrate RF radios, wattmeters, directional couplers and other high-power RF test equipment in the field or metrology lab. Unlike other calibration solutions, the SMK-3000 calibration kits reduce the cost of ownership and provide a much faster time-to-calibration with lab precision and accuracy you’ve come to expect from Bird.
-
Product
Balance Thermocouple Power Sensor, DC To 18 GHz
N8481S
Power Sensor
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
Product
Calibration
-
General purpose calibration/diagnostic tool.Built in precision resistors.Simple manual contact/routing/resistor selection.4mm terminal posts on key device connections.In line mode to aid fixture wiring/DUT debugging.Comprehensive documentation including circuit schematics.Connecting cables.
-
Product
In-Circuit Test System Calibrations
Test System
Regular calibration is essential to ensure accuracy and reliability in testing. Forwessun offers precise calibration services tailored to your test systems, verifying that all components meet industry standards. Our calibration services maintain peak accuracy and compliance, so you can be confident in your system’s performance for any testing application. Choose from one-off calibrations or scheduled service contracts to meet your needs.- HP3070 - Agilent- Keysight - GenRad- Teradyne
-
Product
Torque Calibration
-
Calibration capabilities for torque applications range from 15 inch-ounces to 2,000 foot-pounds with electronically converted readings in every common unit of measure. NIST traceable weights and torsion arms provide traceability on all Process Instruments'' Torque Calibrations. Force gauges and torque transducers can also be calibrated with this system.
-
Product
Portable & Automatic Pressure Calibrators
-
While we've been producing automatic pressure calibrators for years, we set new company standards to achieve greater customer satisfaction with our latest models. Our new options in the 761A line which offers greater flexibility in multi-range selection, multiple external pressure module management, and speed-to-pressure improvements. Each of our Additel 761A automatic pressure calibrators is now conveniently transportable, as well as Bluetooth, Wi-Fi, and Ethernet enabled.
-
Product
Calibration & Testing Unit for AC & DC Meters
-
Supreme Instrument Laboratories
Calibrator for calibration and testing of A.C. Milliammeters, Ammeters, Voltmeters, and D.C. Microammeters, Milliammeters, Ammeters, Millivoltmeters and Voltmeters having following technical specification
-
Product
Mineral Insulated Thermocouples IEC
-
Durable Mineral Insulated type thermocouples to suit a wide range of temperature measurement. Various probe types, lengths and diameters available.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Voltage And Current Calibrator
-
Precision Mastech Enterprises Co.
A precision instrument designed to generate (source) and measure precise electrical signals.
-
Product
MAX31855 J-Type Thermocouple Arduino Shield
SEN-30004-J03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855J supports a measured temperature range of -210C-1200C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
Automatic Calibration Module
ACM2708
-
ACM2708 is an automatic calibration module that can be used with CMT Vector Network Analyzers operating in frequency range up to 8 GHz. The ACM 2708 is a 75 Ohm calibration module for use with native 75 Ohm VNAs (S7530) while also covering automatic calibration for 50 Ohm VNAs with the use of 50 to 75 Ohm matching pads.
-
Product
Current Probe Calibrator
KSZ
-
PMK Mess- und Kommunikationstechnik GmbH
Since Current Probes are often exposed to hard working conditions, a performance check is recommendedbefore every use. These Current Probe Calibrators generate square wave pulses from 0.05 A to 1000 A with an accuracy better 1%. They qualify for calibration and adjustment of Current Probes.
-
Product
SparkFun Qwiic Thermocouple Amplifier
MCP9600 (Screw Terminals)
-
The MCP9600 Breakout is a high accuracy Thermocouple Amplifier equipped with an I2C interface, accessed over our Qwiic system. Inside the chip are two temperature sensors, one for the thermocouple itself (the hot junction) and one for the chip itself (the cold junction). As a result, the MCP9600 can read both the ambient temperature and the temperature of whatever you're trying to measure! The MCP9600 can do both with a resolution of 0.0625°C, and an accuracy of ±1.5°C (worst-case). The MCP9600 Thermocouple Amplifier is one of our many Qwiic compatible boards! Simply plug and go. No soldering, no figuring out which is SDA or SCL, and no voltage regulation or translation required!
-
Product
Measuring and Calibration Stations
PCB
-
Is used to measure electric and magnetic fields of an ESD generator
-
Product
Portable Gas Calibrator
Model T750
-
Teledyne Advanced Pollution Instrumentation
The Model T750 is a portable, microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750 is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.The Model T750 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPT. A number of calibration sequences may be programmed into the non-volatile memory of the Model T750, covering time periods up to a year.
-
Product
Gauge Type T Thermocouple Wire
W-TW-30
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Calibration Pulse Processor
2401
-
TESCO’s Calibration Pulse Processor (Catalog No. 2401) adapts to any Next Generation three phase test board to directly calibrate with three independent single phase standards.
-
Product
Thermocouple Power Sensors
N8482H
Power Sensor
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
Product
16 Inputs Temperature Data Logger – Thermocouples
HD32.8.16
-
Rugged data logger with 16 inputs for K, J, T, N, R, S, B and E type thermocouple
-
Product
MAX31855 J-Type Thermocouple Arduino Shield
SEN-30004-J47
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855J supports a measured temperature range of -210C-1200C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
Backflow Test Kit Repair Calibration & Certification
-
Meeting Water Safety regulations and standards has become a primary concern for all industries. Most municipal and state regulators demand that Backflow Prevention Testing be carried out no less than once per year and that testing devices be calibrated and if required, certified regularly.





























