Resistance Standards
See Also: Resistance, Resistivity, Resistance Meters, Resistance Test
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2T
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Global Standard Model For 4 Point Probe Sheet Resistance Automatic Measurement System
RT-3000/RG-1000F
-
*Fully automatic system for large sizes of flat panel with glass loading robot*Tester self-test function, Measurement position correction function, wide measurement range*Min. 0.1 mm meas. resolution and user programmable test pattern*Host (CIM) communication and 2-D/3-D Mapping software
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1R1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4G
-
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Resistive AC Load Bank
-
AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1W1S
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
European Standard for Remote Reading of Measuring Devices
M-Bus
-
M-Bus (Meter-Bus) is a European standard for remote reading of measuring devices. M-Bus is predominantly used in buildings, for example in electricity meters, gas meters, water meters or other types of consumption meters. It is also used for various sensors and actuators.
-
Product
Electronic Resistance Store
MEMS5
-
Mezzanine MEMS5 is designed to reproduce the values of resistance to direct current through five channels independent and galvanically isolated from each other and from the case.
-
Product
Live Line Clamp Insulation Resistance Tester
MLIT-1
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Easy and convenient live line insulation measurements for servo motor,inverter motor and power line.・More than 0.1MΩ for power line.・More than 10MΩ for servo motor and equipment.
-
Product
Insulation Resistance Measurement
MI15KVe
-
The MI-15KVe High-Voltage insulation tester is a truly portable device that allows the measurement of insulation resistances using test voltages up to 15kV.
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2262AG-1C1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Resistance Meter
MT16-4L
-
М-module МТ16-4Л is a mezzanine module (hereinafter referred to as a mezzanine), designed to measure the resistance of resistive sensors using a four-wire measurement circuit in sixteen channels (sixteen-channel digitizer). М-module МТ16-4Л is installed on the mezzanine carrier - module НМ-М and is connected to it via a local information highway. Up to four mezzanines of various types can be installed on the NM-M module. The NM-M module, together with the mezzanines installed on it, forms a VXI module of the C-1 size and is used to create information measuring VXI systems.
-
Product
Resistivity Imaging & Sounding System
Syscal Junior Switch
-
The Syscal Junior is an all-purpose resistivity imaging and sounding system for environmental applications. The system can be supplied as a standard imaging system capable of recording two measurements simultaneously. The second recording channel significantly improves data acquisition time when the instrument is fitted with internal switching board for 24 (Switch-24) 48 (Switch-48) or 72 (Switch-72) electrodes for Electrical Resistivity Tomography (ERT).
-
Product
Analyse-it Standard Edition
-
The powerful statistical analysis and regression you'd expect from an expensive statistics package.
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25HF-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52T
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Field thermal needle system for thermal resistivity / conductivity measurement
FTN01
-
Hukseflux Thermal Sensors B.V.
The FTN01 Field Thermal Needle System allows performing fast, on-site measurements of the thermal resistivity or conductivity of soils, in particular around the typical depth of burial of high voltage cables. FTN01 is designed with a focus on robustness and saving time, while still offering sufficient accuracy for typical field measurements. The sensor is a Non-Steady-State Probe (NSSP), TP09, which is mounted at the tip of the Lance LN01. The system is operated using a hand-held Control and Readout Unit CRU01.
-
Product
Analog Insulation Resistance Tester (CE)
MIS-A
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
The single and fluorescent scale indicator for 3 ranges insulation measurements enabled easy observation. Especially, useful when working in dark place. Hand free and continuous measurements with custom made switch. Safe design with built in automatic discharging function for any capacitors present in the circuit. The voltage in the circuit can be pre-checked without any switch operation for safe insulation measurements. Compact, light weight and heavy duty rugged case.
-
Product
Electrical Resistivity Instrumentation
-
The resistivity survey method is more than 100 years old and is one of the most commonly used geophysical exploration methods (Reynolds, 1997). It has been used to image targets from the millimeter scale to structures with dimensions of kilometers (Linderholm et al., 2008; Storz et al., 2000).
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50T
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
High Resistance Neutral Grounding Devices
-
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
Product
STANAG3910/EFEX Test And Simulation Module for Standard Ethernet
ANET3910
-
STANAG3910/EFEX Test and Simulation module for Standard Ethernet. The ANET embedded Linux Operating System gives the unique capability to run the optional PBA.pro Engine right in the box. Another option is the ANET-ADK onboard software development kit where users create run-time applications (e.g. STANAG3910/EFEX to Ethernet Converter, STANAG3910/EFEX to Ethernet Gateway) to execute right in the box. For wireless applications, an ANET compatible USB Wifi dongle is optionally available.The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
Product
Rack Module with Standard Contactors without Anti-Harmonic filters
MOD Rack
-
Lifasa - International Capacitors, SA
The MOD-RACK control units include, in a compact form, all the components necessary for the operation of a step of a standard capacitor bank. MOD-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
Product
Fuse Saver Standard Kit
#8005
-
Innovative Products of America
The Fuse Saver provides a fast and safe solution to the old methods of "smoke testing" a short. This all inclusive kit includes a durable custom blow molded case. With the Fuse Saver you can move about your vehicle while checking for shorts in the electrical system.
-
Product
AC Load Bank (Resistive)
K-1000 Resisitive
-
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
Product
Earth Resistance Soil Resistivity Tester 2 / 3 / 4 Wire
Model KM 1320
-
Kusam Electrical Industries Limited
KM 1320 Earth Resistance Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage, AC voltage. Adopting the latest digital and micro-processing technology, precise 4-pole, 3-pole and simple 2-pole method for earth resistance measurement, importing FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure highprecision, high stability and reliability for prolonged measure,which is widely used in electric power, telecommunications,meteorology, oil field, construction, lightning protection,industrial electrical equipment and other earth resistance, soilresistivity, earth voltage, AC voltage measurement.
-
Product
Din Abrasion Resistance Tester
SG-P01D
-
This tester is used to determine the abrasion characters of elastomers, rubber, soft synthetics, leather. etc or is with characters of high efficiency, good reproducibility and easy operation.
-
Product
Standard Voltage 37 Pin D-Type Connectors for Pickering
-
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.