describes the induced magnetic flux density (B) in relation to the magnetizing force (H). Also known as: BH Loop
See Also: Hysteresis, Hysteresis Graphs, Hysteresis Curve, Core Loss, Flux Density, BH Curve
-
product
AC Hysteresis Graph Test System
DX-2012SA
Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.
-
product
AC Hysteresis Graph Test System
DX-2012M
Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.
-
product
Automatic Hysteresis Graph Test System
DX-4DMT
X-4DMT automatic hysteresigraph system accords with the standard permanent magnet test system, GB3217-92, used to measure the major and minor hysteresis loops, demagnetization curves, recoil hysteresis loops and initial magnetization curves in different temperature of ferrite, AlNiCo, SmCo, NdFeB and quenched material, and gives the magnetic parameter, Br, Hcb, Hcj, (BH)max, Hk and so on, and could meet different requirements on test function, precision, power capability, reliability, efficiency, price, local environment from laboratory to enterprise's production line.
-
product
DC Hysteresis Graph
DX-2012SD
Automatic measurement on basic magnetization curve and magnetic hysteresis loop under static state of soft magnetic material, accurate measurement on static magnetic characteristic parameters such as initial permeability µi, maximum permeability µm, saturation magnetic induction Bs, remanence Br, coercive Hc and hysteresis losses Pu.
-
product
Vibrating Sample Magnetometer
VSM
The VSM (also named M-H CURVE Hysteresis Graph TEST SYSTEM ) can be used for the measurement of the basic magnetic properties of the magnetic materials. Such as the Hysteresis loops of the materials, Magnetization curve, Warming Curve , Warming /Cooling curve, Cooling curve and the changes of the temperature as time goes away , then we will get some Magnetic parameters such as the Saturated strength of the magnetization, the left strength of the magnetization , Coercive force, the Max of Magnetic energy product,the Curie temperature and the Magnetic conductivity(the Initial Magnetic conductivity is included ). It can also measure the magnetic materials such as the powder, the particles, the films, the liquid and the massive.
-
product
Hysteresis Loop Tracer
MESA
The MESA is the only hysteresis loop tracer on the market that can make measurements in the frequency range of 10 Hz and below. Competing units operate with more-easily generated 60 Hz drive fields, and can have errors of as much as 30% in coercivity (Hc) measurements.
-
product
Magnet Tester
H30 Series
AlmiCo, Ferrite, NdFeB, SmCo5, Sm2Co17 magnets are tested and their B-H and MH loops are plotted using Ferrites India make H30 Series hysteresis loop tracers. The complete system consists of a magnetizer to magnetize the test piece, an electromagnet and a BH Loop Plotter. Magnets with coersivity as high as 13 kOe and more can also be tested.
-
product
Fluxmeter
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
product
Material Science Laboratory Instruments
our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.
-
product
Soft Iron Tester
WP2
Computer aided measuring set for automatic measurement of the hysteresis loop of soft magnetic materials. Allows measurement of workpieces with different length and cross sections.
-
product
Magnet Tester
MP
Computer aided measuring desk for automatic measurement of hysteresis loop of hard magnetic materials. Use pole pieces with integrated measuring coils, or J-compensated surrounding coils.
-
product
Stress Hysteresis Measurement
500 Series
Stress Hysteresis Measurement up to 500C for thermal property and stability tests of thin films in air.Non-Contact Laser Scanning Technology.
-
product
Hysteresis Graph
MAGNET-PHYSIK Dr. Steingroever GmbH
The measurement of magnetic material parameters using hysteresis graphs is of utmost importance for both material manufacturers and users. Discover the hysteregraphs from MAGNET-PHYSIK in Cologne.
-
product
Loop Antennas
A loop antenna is a radio antenna consisting of a loop or coil of wire, tubing, or other electrical conductor, that for transmitting is usually fed by a balanced power source or for receiving feeds a balanced load.
-
product
Stress Hysteresis in vacuum or gas up to 900C
900 Series
Stress Hysteresis in vacuum or gas up to 900C for the study of annealing cycles.Thermal Desorption, Film Shrinkage, Reflectivity, and Resistivity options provide additional insight to causes of material changes with temperature.
-
product
Monitoring Loops
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
product
Quad Op-Amp Loop
QOAL400
The QOAL400 module is a precision instrument capable of measuring all common parameters of an Op Amp, including AC as well as DC parameters. The QOAL400 has four completely independent channels, which allow a quad device to be tested in a minimum amount of time. Each channel has a full set of resources to measure all common parameters.
-
product
Active Loop Antenna
KH30935
Beijing KeHuan Century EMC Technology Co,.LTD
KH30935 active loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna has a small outer diameter and light weight, which is convenient for outdoor measurement.
-
product
Open And Closed Loop Inverters
VFD
Inverter products support the energy-saving operation of equipment and machinery with fine speed control.
-
product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
product
Loop Impedance Tester
CZ20054
Australian and New Zealand standards mandate testing of fault loop impedance on circuits not protected by RCD's, both at installation and after maintenance. The CZ20054 Loop Impedance Tester conducts earth fault loop impedance and prospective short circuit current (PSC) tests. The Aegis Loop Impedance Tester takes the confusion out of loop/psc testing by providing an automatic wiring check upon connection and single button operation.
-
product
Single Loop Controller
1460
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
product
MULTI-STANDARD LOCAL LOOP SIMULATOR
458-LM-A8-30
Accurately simulates attenuation and impedanceFull bidirectional operation at all specified frequencies26 AWG PIC as specified in ANSI T1.417
-
product
Local Loop Simulator 128 Channels
458-CC-16/458-CM
FEATURES: Accepts 1 to 16 Line Modules; User-Friendly Interface; Multiple Configurations; Field-Upgradeable Software; One-Year Warranty/Calibration. The 458 Series 16-slot Chassis, which consists of the 458-CC chassis and one of three control modules, provides a wide variety of configurations through use of up to 16 plug-in Line Modules.
-
product
Current Loop Adapter
OP-1C
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
Helmholtz Coils / Radiating Loops
Formed by a pair of conducting circular coils with many turns, each carrying a current. The coils are separated by a distance equal to the radius of the circular loops.
-
product
Single Loop Controller
1160+
The 1160+ controller is an evolved product from the West N6100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
product
Digital Phase Locked Loop (PLL)
A6-CPS
The A6-CPS digital phase locked loop (PLL) can be customised to a specific application and shipped ready for use in production.
-
product
Current Loop Supply Isolating Transmitter
Model TWS / TWS 2
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)