PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-112
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Micro Power Insert, Receiver, SIM, 2 Position, 2 Slot
510180102
This insert contains 2 micropower contacts and is part of the Infinity Connector system. It is used in the 90 Series SIM Module and occupies 2 of the 34 slots in this module. This insert comes loaded with contacts. Individual contacts sold separately p/n 610142106.
-
product
PXI 22-Channel 2A Fault Insert Switches
40-202-001
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Micro Coax/Micro Power, Module Insert, ITA, i2 MX, 15 Position
510144009
Micro Coax/Micro Power, Module Insert, ITA, i2 MX, 15 Position.
-
product
64-Ch 1-Bus Fault Insertion
YAV91082
64 channels 1 thread 2A 250V 1 Fault Insertion Buses Switching up 60W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
VTAC, Insert, Receiver/ITA, SIM, Pass-Thru, 8 Pos, 1 Slot
610151103
VTAC, Insert, Receiver/ITA, SIM, Pass-Thru, 8 Pos, 1 Slot VTAC inserts are reversible and can be used as a Receiver or ITA insert.VPC's revolutionary high speed VTAC insert contains 8 gold-plated, self-aligning contacts and is designed to reduce crosstalk. With a data transfer rate of more than 12.5 Gbps per differential pair and a cycle life of over 150,000, VTAC has set the standard for high speed interconnect solution requirements. Sold in individual quantities.Use with VPC's right angle VTAC insert (p/n 610151104) or VPC's vertical header (p/n 610151107) to connect directly to a PCB.
-
product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Return Loss, Impedance & Balance Measurement Accessory
Model SLM620-1
For Loss- Frequency Range : 300Hz to 620KHz.- Impedance : 60 to 1000 ohms (40dB maximum).- Accuracy : ±1dB (upto 300KHz) ±2dB (300KHz to 620KHz).For Impedance- Frequency Range : 300Hz to 620KHz.- Impedance : 60 to 3000 ohms.- Accuracy : ±10% (upto 300KHz) ±20% (300KHz to 620KHz).
-
product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Fluid Loss
Fluid Loss testers were designed to be as easy to use as possible, with clear and intuitive controls. Once the cement slurry or mud is placed into the test cell, a programmable temperature controller increases the temperature at the desired rate.
-
product
Dual Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-102
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
Handheld Return Loss Tester
JW3308
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW3308 handheld return loss tester is used to measure the return loss in the field fiber optic linking, in order to adjust the quality of the optic fiber end-face, and to make sure the fiber optic communication is in good condition. This 3308 handheld return loss tester can realize measurement of Return Loss, Insertion Loss, Output power, and also can be used as the laser source. Moreover, it has the data storage function of 500 measurement items.
-
product
Inversion Loss
DSP-1L
Is used to protect your three-phase motors against loss, imbalance or inversion. It continuously monitors each phase of your power supply. In case of phase loss, imbalance or inversion, the DSP-1L cuts off the power to the control circuit and thus protects the motor concerned.
-
product
PIM & Return Loss Measurement
Range to Fault (RTF)
Range To Fault (RTF) is an exciting new technology from Kaelus that enables operators to accurately measure the location of PIM and Return Loss faults in their RF infrastructure. Reflection data together with PIM data provides an unmatched level of clarity for identifying the location of faults in the RF path.
-
product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
42-205-008 (PXIe) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
product
Optical Return Loss Meter
ORL
•Four functions in one•Power meter and light source•Return loss meter and insertion loss meter•3 wavelength detection(1310/1490/1550nm)•Rugged, shock and water-proof for field use•Compact size, lightweight and cost-effective•Quick and easy to operate
-
product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-302
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-012
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Signal, Module Insert, Receiver, i2 MX, 84 Position, QuadraPaddle, Crimp
510143002
Signal, Module Insert, Receiver, i2 MX, 84 Position, QuadraPaddle, Crimp.
-
product
Low Loss Combiners
*Tunable or band specific low loss combining of Tx and Rx*Typical 0.7dB insertion loss*Optional second duplexer can be installed in the same tray*High power handling with low IM and insertion loss*AISG 2.0 compliant
-
product
Core Loss Testers
S30 and S30S Series
Stacks built with punched laminations can have a lot of quality issues. Even though the lamination material is tested in sheet format before any process, that alone is not sufficient to guarantee good quality stators. Wear and tear of the punch, bad welding, bad insulating coating in annealing add to the magnetic losses in the stator. It is always advisable to test the stator core in it's final format before winding to ensure good quality throughout the production batch.