Compensators
-
Product
Linearizers
-
Gain Shape Linearizer Amplifiers are used in a number of applications where it's necessary to flatten the gain characteristic of the preceding or following component. This would include flattening the attenuation of a long cable run, or perhaps changing the input gain response to an MPM (Microwave Power Module) or TWT (Traveling Wave Tube) to compensate for the gain variation within the tube.
-
Product
Manometers (Pressure)
-
Test Products International, Inc.
All TPI manometers feature temperature compensation to ensure reliable, repeatable measurements. Over-pressure protection prevents sensor damage due to inadvertent pressure spikes. Wide input ranges and high resolution increases versatility and performance.
-
Product
Temperature Measurement Products
-
Precision devices and sensors used to track temperature, display thermal readings, and provide Automatic Temperature Compensation (ATC) for water quality and laboratory analysis.
-
Product
Oxygen Gas Analyzer
KM 5490
-
Kusam Electrical Industries Limited
• As it uses a high quality oxygen sensor, it is very precise and its performance is stable.• It uses the advance technology design and has multiple functions.• With highlight backlight display and acousto-optic alarming, it is easily configured.• The in built temperature compensation makes the meter measure the correct value of oxygen in the environment temperature of -10 ~ 40�C.• As its case is ergonomically designed, it looks elegant, and is easy to carry.
-
Product
Power Conversion
-
The XRP6124 is a non synchronous step down (buck) controller for up to 5A point of loads. A wide 3V to 30V input voltage range allows for single supply operations from industry standard 3.3V, 5V, 12V and 24V power rails. With a proprietary Constant On-Time (COT) control scheme, the XRP6124 provides extremely fast line and load transient response while the operating frequency remains nearly constant. It requires no loop compensation hence simplifying circuit implementation and reducing overall component count. The XRP6124 also implements an emulated ESR circuitry allowing usage of ceramic output capacitors and insuring stable operations without the use of extra external components.
-
Product
Probe Cards
Minitile™ with Advanced Cantilever™ technology and WedgeTile™
-
Each probe is designed for wide temperature ranges and so the probe expansion characteristics are closely matched to the wafer’s expansion characteristics. This allows the user to take a fast measurement while a system is in a settling or thermal stabilization mode and helps compensate for wafer expansion.
-
Product
pH 700 Benchtop pH Meter
-
The easy-to-use, microprocessor-based pH 700 benchtop meter measures pH, mV, relative mV, and temperature. The large, dual-display LCD provides excellent visibility—even from a distance. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. Meter features HOLD, ATC, selectable °F or °C measurement, recall of electrode slopand offset, and electrode diagnostics. The convenient pull-out quick reference card keeps procedures handy at all times. Meter accepts any pH or ORP electrodes with a BNC connector.
-
Product
10:1, 10 Mohm, 300 MHz Passive Probe
PP016
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
ION 100 Portable Ion Meter
-
The new addition to the Environmental Express Oakton product line features updates to measuring water quality easier and faster. The larger LCD display is 2.75 in. by 2.0 in. for a better viewing angle, and has indicators for battery life, stability, and calibration. The ION 100 meter measures pH, mV, ion concentration of 16 commonly measured ions, and temperature. The microprocessor-based meter features automatic calibration, automatic temperature compensation, function setup, self-diagnostics, automatic power-off, and low voltage display. The meter uses advanced digital processing technology, intelligently improving the response time and accuracy of your measurements. Easily switch units among pX, mol/L, and mg/L (ppm).
-
Product
Battery Chargers
-
Following a power outage, various power engineering objects such as power plants should operate on battery back-up systems. It is necessary that these batteries are being properly charged in order to compensate its energy loss and keep their voltage within the predefined limits. DV Power’s chargers are portable and universal battery charging solution. They are primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300 V DC level.Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge. Variety of implemented protections, such as thermal, overcurrent, undervoltage and overvoltage, assure the charging process is safe for the battery and the charger itself.
-
Product
Salt Contamination Meter
130
-
Key features of the Elcometer 130 Salt Contamination Meter include:Fast reading rate allows multiple conductivity tests to be completed efficientlyPressure plate ensures a constant and uniform pressure to paperAutomatic detection of paper size and automatic adjustment of reading valueUSB and Bluetooth® data output to ElcoMaster® softwareDust and water resistant rugged design equivalent to IP64Automatic temperature compensation ensures accurate resultsNon-oxidising gold plated contacts ensures lifetime accuracyStores up to 150,000 readings in 2,500 alpha numeric batchesFully portable hand-held, ergonomic design ideal for use in the field
-
Product
PRO+ 2-in-1 pH and Temperature Meter
MW102
-
The Milwaukee MW102 PRO+ pH meter has won fans around the world with its reliable, fast and simple operation as well as its toughness. Accurate to ± 0.02 pH with automatic temperature compensation. Ideal for use by brewers, wine makers, growers and other users with challenging pH measurement needs.
-
Product
C-Band Single Channel Line Amplifier EDFA (SLA)
HSA4200 (With SNMP)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HSA4200 series is a line EDFA designed specifically for single wavelength optic transmission system. It is installed in the middle of the transmission line, replacing the traditional relay station, to compensate the optical power loss in the line and extend the signal transmission distance.
-
Product
Thermal Mass Flowmeters
-
ABB’s thermal mass flowmeters are suitable for all industrial and test rig applications that demand quick and precise gas measurement. The flowmeters directly indicate the mass flow or normalized volume flow of gases without any additional pressure and temperature compensation. They have an impressively high accuracy, short response time and a very wide flow range with virtually no loss of accuracy even at the lowest flow rates.
-
Product
Fluid Level Sensor
-
The output of the fluid level sensor is a voltage which changes in direct proportion to the level of fluid in the probe. The difference in permittivity between air and the fluid being measured changes the capacitance between the probe's two concentric tubes as the level changes. An RS232 connection to a PC allows the user to calibrate the fluid level and thermal drift compensation. The probe is factory replaceable, allowing the electronics to be re-used should the probe become damaged or if a new probe length is required.
-
Product
Full Bridge Thin Beam Force Sensors
TBS SERIES
-
The TBS Series thin beam force sensors many different parameters found in medical instrumentation, home appliances, process control, robotics, and automotive are exceptionally suited for small load measurements. They are designed to measure and many other high volume applications. A specially developed integrated strain gage includes all balancing, compensating and conductive elements and is laminated to the beam to provide excellent stability and reliability.
-
Product
L.V. Power Capacitors
-
LV power capacitors are circuit elements which compensate the inductive reactive loads on a system. Being able to connect and disconnect up to 100 times a day in accordance with load variations in automatic reactive power compensation systems really speaks for the quality and endurance and capacitors. Upon connection/disconnection instances, currents which have higher values than the nominal value may occur on reactive power compensation capacitors. ENTES ENT.C series power capacitors are designed to withstand the severe and poor conditions which may shorten the operating life during reactive power compensation. This endurance is the result of advanced engineering and long-term test procedures.
-
Product
Process Ozone Sensor
Model 452
-
Teledyne Advanced Pollution Instrumentation
The Model 452 is a microprocessor based gas sensor for measuring high concentrations of ozone in oxygen or air with accuracy and dependability. The measurement principle is based on the absorption of UV light at 254nm. Readings are available in % by weight, or grams/Normal cubic meter. Temperature and pressure compensation up to 3 Bar Absolute is a standard feature.
-
Product
HPLC Pumps
MX Class
-
Further applications include demanding metering and dispensing, as well as Sample Injection, Infusion, or Cone Wash for Mass Spectrometers. Standard fluid path material is Stainless Steel. With flow rates up to 10 mL/min, these pumps can tackle the majority of demanding laboratory applications.Features include pressure monitoring with automatic pressure compensation, Pulse Dampener, integrated Prime-Purge Valve, interactive keypad control, and complete PC control and status through RS-232, micro-USB 2.0, and Ethernet serial communications. Requiring minimal bench space for the performance, the MX Class will easily integrate into most workspaces.
-
Product
Handheld Water Quality Meters
LAQUA PH210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers) - 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
Product
Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm
PP020-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Milli-OHM Meter
MR-30
-
*Double LCD Display*300,000 counts resolution*Measurement Range: 30mΩ~3MΩ*0.05% accuracy*20 Standard User setting memory sets*Sorting function and Relative percentage function*PASS/FAIL test result alarm*Computer Remote Manual and Auto Scan function*Manual and Auto Channel select*Sampling Rate: 30 sample/sec*High Resolution Temperature compensation and measurement*DUT Four-wire method*USB interface
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Head-Mount Temperature Transmitters
-
The compact head mounted temperature transmitter type from ABB is designed for standard type B sensor heads. The advantage increased measuring accuracy resulting from conversion of the sensor signal into a stable output signal close to the sensor. When using thermocouples, no compensating cables are therefore required.
-
Product
C Series Temperature Input Module
Module
The C Series Temperature Input Module features up to 16 channels of temperature input from either thermocouples or RTDS. This module can include anti-aliasing filters, open-thermocouple detection, and cold-junction compensation. Additionally, the module also feature isolation for safety, noise immunity, and high common-mode voltage range.The C Series Temperature Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
EIS Battery Analyzer
BA8100
-
The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.
-
Product
PH And Temperature Pen
Ultrapen™ PT2
-
This instrument is designed to be extremely accurate, fast and simple to use in diverse water quality applications. Advanced features include automatic temperature compensation; highly stable microprocessor-based circuitry; user-intuitive design; and waterproof housing. A true one-handed instrument, the PT2 is easy to calibrate and easy to use. To take a measurement, you simply push a button then dip the pen in solution. Results display in seconds.
-
Product
8 Channels, RTD Measurement
RT1
-
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
Product
Electronic Differential Pressure
Density Measurement
-
An innovative software and hardware concept makes it possible to combine any two pressure transmitters of the VEGABAR 80 series into an electronic differential pressure system to measure density. Electronic differential pressure measurement is used for measuring density change and/or for compensation when the level needs to be measured.
-
Product
pHTestr® 30+ Waterproof Pocket Tester
-
Waterproof pHTestr 30 is great for outdoor applications such as taking pH measurements in lakes and streams. Designed to float in water, you can even attach a line to the housing for easy retrieval. Valox sensor housing resists most chemicals.The pHTestr 30 has a replaceable sensor for easy maintenance. pHTestr 30 purchased before Oct. 2019 use replacement sensor 35624-38. pHTestr 30 purchased after Oct. 2019 use replacemenr sensor 35634-03. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage.The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include a automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.





























