-
Product
Series Precision Multi-Ratio Current Transformers
PMT25090
-
Power Measurement Technologies Inc.
Precision two-stage toroidal current transformers find application as the reference in determining the accuracy of instrumentation current transformers.
-
Product
Current Transformers
-
Contrel Elettronica s.r.l. Company
We can supply current transformers (measure transformers, protection transformers and double ratio transformers, with analog output) with the following accuracy classes: 0.1, 0.2s, 0.5s; 1; 3. A wide range of combinations is available in our standard range with specific versions available upon request (other ratios, specific frequency, class or load). They are equipped with sealable terminal covers as standard.
-
Product
Transformers & Reactors
-
Our company leads the market by manufacturing and exporting a wide range of Transformers & Reactors. We manufacture these equipments in different models and technical specifications to suit clients' demands. Our highly skilled team use best grade raw materials and components to manufacture these Transformers & Reactors. We offer these equipments to clients at competitive prices.
-
Product
Precision Multirange Current Transformer
P-5000
-
The P-5000 transformer is a laboratory standard. The unit’s excellent accuracy and the Knopp One-to-One calibrating feature make this precision transformer well-suited as a standard for calibration work. This transformer can provide a very accurate determination of the ratio and phase angle characteristics of current instrument transformers having ratios from 5 to 5,000 amperes. This transformer also can accurately extend the range of a 5 ampere ammeter or wattmeter to cover all current values up to 5,000 amperes.
-
Product
Automatic Voltage Transformer Comparator
KATC-V2
-
Knopp’s KATC-V2 is a highly accurate state-of-the-art voltage transformer comparator that is compatible with all older generation Knopp comparators, and is designed to be a direct, plug-in replacement with additional test set cables to fit in the existing Knopp Voltage Transformer Test Systems.
-
Product
Automatic Meter Reading Unit
-
Signals & Systems India Private Limited
SANDS make of AMR Modem SAM-1101 is a smart electricity meter reading device that can be connected to any make of electronic energy meter by means of optical/ RS232 port, which is compliant to DLMS – IEC 62056-21 standard. The electricity meters measuring energy consumption can be located in either consumer premises or in distribution transformers. The modem draws its power from the meter terminal block and connects to the communication port of the meter. Thus this add-on energy meter reading system is non-intrusive and can be retrofitted easily to any meter. The Electricity Meter Reading device uses GSM/GPRS communication technology and has built-in intelligence to talk to the DLMS meter. AMR system is compatible with 4G network to push the power consumption-billing data, load survey data, and event data to a cloud-based server, with fallback options to 3G & 2G.
-
Product
CT Burden Tester
585
-
The 585 Burden Tester is a hand held unit rated for use up to 20A. The design features a digital LED meter for displaying the current transformer (CT) secondary current. The burden is applied for a specific length of time controlled by circuitry inside the unit to help prevent the burnout of the burden elements.
-
Product
400/5A CHEAP SPLIT CORE CAST RESIN CURRENT TRANSFORMER
LZCK310-10
-
Beijing GFUVE Electronics Co.,Ltd.
LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
-
Product
CT Analyzer
PCT200i
-
PCT200 series CT test set (CT Analyzer) is a current transformer test equipment specially designed for current transformer characteristic test and with additional PT test functions for reference test. PCT200i owns more test items and higher technical parameters.
-
Product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
-
High Voltage SCR Controlled Power Supply, P/N 18278PSPower Rating: 350 KW.Input: 480 VAC, 3 PH, 60 HzOutput: 0 to 5000 VDC, 70 Amps maxRipple: 2 % approximately at maximum rated voltageConfiguration: 12 pulse externally SCR controlled rectifier systemProtection Devices:Input contactorsOverload relay shutoffInput surge suppressorThermal switchesOutput current limiting resistor (made with 5 Ohm Kanthal heating element)Emergency power shutoffCooling: Each 6 pulse rectifier assembly is cooled by three 10” fansInterface: 4/20 ma converter interface for output voltage and output current to SCR controller.Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier.Weight: Approx. 5000 lbs.SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack.Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configurationRectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure.Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)
-
Product
Transformer Ratio Meters / TRM-101
TRM-101
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Produces the 3-ph or 2-ph standard power with stable voltage and phase. Fully automatic: No manual balancing
-
Product
Synchro to DC Sine / Cosine Converters
SD
-
Computer Conversions Corporation
This unique series of Synchro to DC Converters makes use of advanced digital circuitry techniques to accomplish high speed conversion with extreme accuracy. Transformer isolation as well as balanced line-to-line input impedance is provided for superior and trouble-free system performance, regardless of the input synchro used.
-
Product
Automated Test Equipment
-
Viewpoint Systems offers design verification and manufacturing quality inspection systems to help customers reduce human error in repetitive tests, increase testing speeds, and ultimately get products to market faster at a lower cost. Viewpoint Transforms Test from Design to End-of-Line. Our R&D test systems are designed with the flexibility to validate ever-changing prototypes while accelerating your development schedule.
-
Product
Rapidox 6100 Pump Back Gas Analyser
-
The Rapidox SF6 6100 Pump Back is a fully-automatic zero-emissions SF6 gas analyser, designed for controlling and monitoring the quality and purity of gas used in high voltage switchgear, circuit breakers and transformers.
-
Product
Power Calibrator And Protection Relay Test Set
CP11B
-
Calmet Smart Calibration Devices
Single phase, class 0.02 and 0.05 power quality calibrator up to 120A and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.
-
Product
Inductive sensors
-
Inductive sensors are signal generators which detect function-related movements of processing machines, robots, production lines, conveyor systems etc. in a contactless fashion, and transform them into electrical signals.
-
Product
Switch Module
STCS PLUS
-
The external module STCS Plus allows to run automatically and with a single set up, any kind of tests on power transformer.
-
Product
Split type AC Current Transformer
CTS-200
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy installation by metal fitting.
-
Product
Noise Location Package
Type HFDF
-
National RF’s Type HFDF high frequency location system is a proven noise hunting and location directional antenna system that allows you, in many cases, to walk right up to the source of High Frequency (HF) noise! Used by several power companies around the United States, professional noise hunters, and other communications specialists, the HFDF has located noise sources that emanated from pole power transformers, arcing electric fences, CATV in-line amplifiers, plasma TV screens, and even Marijuana grower’s heating lamps! The system incorporates several plug-in, tunable magnetic loop sensors of a proprietary National RF design, that cover the frequency range between 1.8 MHz and 55 MHz. The unit is packaged in a hand-held, lightweight metallic enclosure, with a pistol grip and a magnetic compass mounted on top. The compass is used to get magnetic bearings to the noise source, which may be plotted on a map to triangulate, and ultimately pin-point, the location of the noise source. In certain cases, our customers tell us that they have been able to walk right up to the interfering noise source and correct the situation on the spot!
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
ACDC
ES Series
-
The ES Series of line operated power supplies features near constant efficiency over theentire rated input voltage range. These electrically identical families employ a highly efficient, closed loop ripple regulation circuit, which contains a low pass filter. Each stage, transformer, filter and regulator is engineered for maximum efficiency.
-
Product
Insulation Testing
-
Weshine Electric Manufacturing Co., Ltd
Insulation is one of the most important constituents of a transformer. Any weakness in the insulation may cause failure of transformer. To ensure the effectiveness of the insulation system of a transformer, it must confirms the dielectric test. But the power frequency withstand test alone can not be adequate to demonstrate the dielectric strength of a transformer.
-
Product
MIL-STD-1553 Fiber Optic Bus Extender
FO-1553
-
Avionics Interface Technologies
Extends MIL-STD-1553 bus access to over 1 mile for remote access - Dual redundant, single and dual stream options available - Both Transformer and Direct coupling modes supported - Uses fiber optic 1.0625 Gbps data rates for low latency over long distances - Optical signaling is not affected by electrical noise and interference - Simple and easy to use solution, no software setup or configuration required - Ideal for applications where test equipment is separated from UUT
-
Product
Switching Power Supplies
-
PeakTech Prüf- und Messtechnik GmbH
A type of power supply that works by switching current into a high-frequency transformer or inductor at frequencies much higher than the input or line frequency
-
Product
Primary Current Injection Set
-
It is widely used in industries for instrument transformer and switchgear testing.
-
Product
Milli Volt Drop Test Set
-
Widely used for testing transformer and switchgear, this equipment is available to clients in different capacities.
-
Product
ATTR Auto Transformer Turns Ratio Tester
-
Chongqing Assen Power Equipment Co., Ltd
Transformer turns ratio tester is a new type of fully automatic tester that uses modern electronic technology to measure the ratio of single-phase and three-phase transformers, and does not require any manual “zero” balance.
-
Product
Current Transformers
-
Excellent measurement technology requires high-quality current transformers. The product portfolio comprises a wide range of current transformers for load currents (operating currents) and residual currents (RCM). Different designs cover a variety of installation situations and metrological requirements, and enable retrofitting. AC/DC sensitive measuring current transformers use a special measurement method to detect both AC and DC currents of different frequencies.
-
Product
Transformer Resistance Testing
-
Weshine Electric Manufacturing Co., Ltd
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the WESHINE Transformer Ohmmeter (VS-3110 series) of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.
-
Product
Three Phase Transformer Ratio Meter
-
*Three phase lead switching network. *Excitation current meter Accessories: Range Extender 1:5





























