Fast Fourier Transform
Fast Fourier Transform
-
product
Transformer Test Equipment
KV Hipot Power Test Equipment Co.,Ltd
Transformer Test Equipment. Ensure that a transformer meets performance and reliability requirements, from the production line to after a repair or upgrade, when a major disruptive event occurs such as a lightning strike, or for preventive/predictive maintenance.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
Automatic Transformer Test System
TH2840NX
Changzhou Tonghui Electronic Co., Ltd.
■ The test speed is as high as 1000 times/s (>10kHz), without relay action time ■ Test level up to 20Vrms ■ The bias voltage is built-in ±40V/±100mA/2A ■ Up to 288 test pins (only TH2840NX) ■ Industry-friendly user experience: Linux bottom layer, built-in help file
-
product
Transformer Winding Resistance Meter
10A
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
product
Fast Response Flow Controller for Medium Flow
HFM-301 / HFC-303
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
product
Automatic Transformer Test System
TH2840BX
Changzhou Tonghui Electronic Co., Ltd.
■ The test speed is as high as 1000 times/s (>10kHz), without relay action time ■ Test level up to 20Vrms ■ The bias voltage is built-in ±40V/±100mA/2A ■ Up to 288 test pins (only TH2840NX) ■ Industry-friendly user experience: Linux bottom layer, built-in help file
-
product
Isolation Transformers
Osborne’s Isolation Transformers are used to step-up, step-down and isolate voltages in single phase circuits. Isolation may be used to provide output circuit immunity from voltage spikes and noise (both common-mode and transverse-mode) present on the input system. The isolation can allow separate grounds on both the input and output sides of the transformer. Osborne also designs with a range of electrostatic shielding to provide several levels of noise immunity.
-
product
Instrument Transformer
CT & PT Test Equipment
Measurements International Ltd.
Calibration of Voltage and Current Transformers from a Single Instrument, Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard, Calibration of Voltage Transformers (VT) up to 800 kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors, Calibration of Current Transformers (CT) Up to 10000 A When Used With MI 7020 and/or 7200 Series of Precision Current Transformers and/or Current Comparators, Test Frequency from 15 Hz to 100 Hz70.
-
product
Transformer Protection
Schweitzer Engineering Laboratories, Inc.
Transformer protection products and systems provide complete primary and backup protection for all types of transformer faults. They are suited for use in utility-, industrial-, and commercial-scale power transformer systems.
-
product
Leather Rubbing Fastness Tester
Sataton Instruments Technology CO., Ltd
Leather rubbing fastness tester is the testing machine which is accordance with the method for determining the color fastness to cycles of to-and-fro rubbing of the surface of leather. The tester can be used for the dry test, wet test and it is also in accordance with the perspiration testing solution as standard requires.
-
product
Auto Transformers
Variac Auto Transformers are continuously variable voltage auto transformer, having a movable carbon tip, fixed to a brush-arm sliding on a silver plated commutator. Rotation of the brush-arm by either manual or motor drive, delivers-an output voltage from zero to or above line voltage.
-
product
Transformer Oil Dielectric Strength Testing
LS -JJ-II
Chongqing Lushun Scientific & Technological Development Co., Ltd.
1.The instrument has the function of automatic detection. 2.Tiny TPU-A panel printer is adopted for automatic printing out type insulating oil dielectric strength ATE is a full self-reacting device, which is developed according to the requirements in International IEC-156 and International GB507-86 "Insulating Oil Dielectric Strength Mensuration", combining the feedback opinions of all users .The instrument adopts singlechip as the leading part, and uses the method of "first setting and then testing". The whole process is controlled by automatic microcomputer. It is operated simply and used conveniently.
-
product
Transformer Turns Ratio Meter
TTRM 102
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
product
Transformer Calibrator
HTQA-C / 345
Wuhan Huatian Electric Power Automation Co., Ltd.
A device used to change the current.
-
product
VARIABLE TRANSFORMER DC POWER
208163V
Motorized Variable Transformer Controlled Power Supply, P/N 208163VInput power: 208 VAC, 6 Amps, 3 PH, 60 HzOutput: 0 to 120 VDC, 16 Amps max.Ripple: 5%Manual control with variable transformerCircuit breaker / ON OFF on the 208 VAC, 3 PH input lineProtection fuse provided on the outputPOWER ON lightIndoor enclosure: 24H x 20W x 9DVoltmeter and ammeter are installed to monitor the output.All input/output connections are available inside the enclosureSystem includes main unit and remote assembly.
-
product
Burn Down Transformer
ATG 2
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
product
Current Transformer
ST-12RCT
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 800~2000
-
product
Super Fast Stand-Alone ISP Programmer
848Pro2
The Dataman 848Pro2 is a super fast stand-alone gang programmer with eight independent 48-pin ZIF sockets, ISP capabilities and internal control PC driven by Windows Embedded 8.1 Industry Pro • Stand-alone operation with touch screen control • Internal control PC driven by Windows Embedded 8.1 Industry Pro • Up to 75% faster programming of high-capacity memory devices • Over 105,000 devices supported with new devices added monthly • Independent modules supporting concurrent programming • Intelligent pin drivers operate down to 1.8V so you'll be ready to program the full range of advanced low-voltage devices • Full ISP capabilities including JTAG compatibility • Comprehensive 3 years parts and labor warranty • Free life-time software updates
-
product
Split Core Current Transformers
Application:Watt Transducer, Current Transducer, KWH Meter, Demand Meter, Power Factor Meter, Current Sensing Relays, Energy Management SystemsContinuous Thermal: Rating 1.25 at 30° C, 1.0 at 55° C Standard 5-amp secondary. Others available.
-
product
Telecom Transformers
Our high-performance telecom transformers support multiple home phone line and power line network applications. These transformers have excellent THD performance, small footprints, and are designed to exceed industry standards. Single, dual, quad, six, octal and twelve transformer numbers are available.
-
product
Super Fast Gang Industrial Universal Programmer
48Pro2AP
The Dataman 48Pro2AP is a super fast industrial universal programmer with ISP capabilities and USB 2.0 connectivity • Optimised for use in automated handlers and ATE machines • Over 71,000 devices supported with new devices added monthly • Mechanically stable case design with multiple fixing points • ISP capable using the JTAG interface • Hi-speed USB 2.0 connectivity • Easy to use software compatible with the latest operating systems including Windows 10 • Comprehensive 3 years parts and labor warranty • Free life-time software updates
-
product
Electronic Transformer Test System
UI2000-ET
• Input characteristics analysis 1) Measure Vrms (10-300V) Lrms (0.04-4A) W, PF, Hz, total harmonic and 0-50 component of harmonic 2) Accuracy: ± (0.4%reading + 0.1%range + 1digit) • Output characteristics analysis 1) Measure lamp voltage (1-60V) lamp current (03-20A) lamp power, crest factor and oscillatory frequency 2) Accuracy: Class 2 • It can print without compute, and provide the communication port for PC
-
product
High Frequency Transformers
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
product
Transformer Turns Ratio Meter XTRM-3
XTRM-3
The Motwane Manufacturing Company
Your product description goes here. Motwane’s transformer turn ratio meter XTRM-3 is a new generation fully automated kit to measure turns ratio, voltage ratio, ratio error, phase displacement & excitation current in a transformer. It automatically detects the transformer vector group. Its user-selectable test voltage feature provides for testing various ratings of power transformers.
-
product
Transformer Monitoring And AVR
Power transformer is a basic equipment for the Transmission and Distribution Network and requires the application of powerful Monitoring and Control Systems. RTU Dt set is developed and intended for medium and large oil immersed Power Transformers with On-load Tap Changers (OLTC). The set provides safe, reliable, easy to use and cost effective power transformer condition monitoring and Automatic Voltage Regulation (AVR).
-
product
Transformer Test
Beijing GFUVE Electronics Co.,Ltd.
Check whether the performance of the transformer meets the requirements of relevant regulations and technical standards.
-
product
Transformer Testers
*Quickly tests deenergized power distribution transformers*Briefly energizes the transformer and takes a snapshot of the condition by measuring the voltage, current and power factor of the test signal*Tests overhead, pad-mount and distribution transformers*Audible alarm confirms successful test*Improve SAIDI statistics by quickly testing and getting the transformer back in service*Auto self-test performed with every test*Compact, lightweight and easy-to-use
-
product
Current Transformers And Shunts
Current transformers allow the different measuring devices to provide reliable and traceable data on the trends involving consumption and production processes in electrical installations. Especially designed to be installed quickly, easily and securely, meeting the most demanding expectations of today's market, covering a wide range of primary currents as well as multiple secondary outputs, both for AC and DC measurement.





























