Working Standards
-
Product
Standard 2.40 (68.00) - 6.20 (176.00) Battery Probe
BIP-8
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 188Test Center (mm): 4.78Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 60Recommended Travel (mm): 1.52Overall Length (mil): 396Overall Length (mm): 10.06
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
-
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1R1S
-
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2D
-
Current Rating (Amps): 5Average Probe Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64Resistance (mOhm): 35
-
Product
Automatic Voltage Regulating Relay- Standard Model
-
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
Product
Digital & ARINC Standards Display Panel
TA-3001
-
This is our soon to be introduced Digital Standards Panel. (2ND QTR) This panel is available with or without a Precision Resolver drive. Included on the panel are four digital displays; TA-902 API, TA903-01 OBI, TA903-02 Distance and a TA903-03 serial distance display. This panel when paired with the TA-3000 GPS/FMS test panel will make one of the most capable testing solutions available today
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T30-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02