Electrodes
-
Product
Low Power Potentiostats
-
Potentiostat Wenking MP 04T, max. current 400 mA, max. voltage 25 V, output power 10 W, reference electrode input 1012 Ohms, slew rate 10 V/ µs, 1 control input, floating current output, buffered potential output, control range ± 10 V external, internal control voltage source ±2 V, rise time constant (closed loop, ohmic load) 1 µs typ., dimensions 165 x 105 x 165 mm (w x h x d), weight 1.4 kg
-
Product
Dielectric/Conductivity Sensor
Mini-VariconTM
-
The Mini-Varicon sensor is a thin, flexible dielectric sensor designed for cost-sensitive use with presses, molds, bulk materials or laminates. Patterned on a polyimide substrate, the electrode array is designed to allow a choice of high or low sensitivity, selected by either using the whole sensor or cutting off a portion of the array at a designated line. The Mini-Varicon sensor can be supplied without leads, or with custom-length Teflon-insulated leads attached.
-
Product
Electric Insulating Oil Tester
PortaTest
-
Portatesters are easy to use. Based on the test standard, you select the corresponding test sequence. Then, the required test probe and the electrode gap for the selected test standard is displayed. The setting gauge, included in the scope of delivery, facilitates the adjustment of the electrode gap. Afterwards you fill the insulating oil in the test vessel and close the test chamber.
-
Product
Open Flanges Test Rig
-
Flexible cell dimensions: cells of Ø 8 to Ø 80 mm (or square till 70x70 mm) can be successively installed Quick start of experiment: less than 20 minutes to remount a new cell with different dimension, thanks to the simple design without sealing Other SOFC components: the open flanges test rig is also useful for conductivity measurements (electrolyte, electrode material, interconnect etc.) and sealing tests End of broken cells and secure testing: the cell is squeezed by a soft alumina felt that prevents any damages, the excess fuel burns continuously in the alumina felt at the cell edges
-
Product
Tracking Index Test Apparatus
CX-L19
-
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
Product
Earth Tester
TAURUS PRECIOHM ET
-
The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.
-
Product
Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)
HC-300F
-
HC-300F is connected to a fluoride ion electrode (1009) to detect free fluoride ions in the sample water.(Total fluorine is not detected.) It is suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers.
-
Product
Scanning Electro-chemical Microscope
920D
-
The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.
-
Product
Multi-probe for Ammonium and/or Nitrate
S470
-
S470 is a complete family of Ion selective electrodes (ISE) probes suitable for monitoring the performance of the ammonium ion (as NH4+ or NH4–N) and nitrate ion (as NO3– or NO3–N) in a liquid matrix.
-
Product
pH Electrodes
-
A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies.
-
Product
Proving Unit & Voltage Tester Kit
DLPK1
-
Touch electrode for Quick testing of fused leads Optical and acoustic continuity Indication Low battery indication A portable, battery powered Proving Unit for testing Two Pole Voltage Testers up to 690V Continuity Tester for testing: Fuses, Fused test leads etc
-
Product
Accessories for Earth Resistivity (VES)
Electrodes
-
Earth resistivity / Accessories for earth resistivity (VES)
-
Product
Integrated Potentiostat and Multiplexer
EmStatMUX8
-
Based upon the EmStat range, there are two types of multiplexers to suit most types of sensor array work. The MUX8 is the most flexible offering the ability to connect arrays made of up to eight working electrodes in two or three electrode cell types and chips sharing a reference electrode and/or counter electrode. The MUX16 is suitable for sensor arrays or chips with sixteen working electrodes all sharing a RE and/or a CE. Both instruments are suitable for laminated layer corrosion analysis.The potentiostat is controlled and powered by USB and is used with PSTrace allowing for simultaneous sampling of each channel at a rate of 25 ms/channel. Standard packaging includes a shielded cable with connections for a working, a counter and a reference electrode by means of 2 mm banana connectors and mini-crocodile clips, a stripped end, Dsub-37 terminated flat cable and a USB cable. To make connections to chips simpler the Connection Terminal is an optional extra providing clearly marked screw terminals to the electrodes and can be directly joined to the ESMUX via their D-Sub connectors.
-
Product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196A
-
The 16196A surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements.