Electrodes
-
Product
Meter With pH Electrode, Conductivity Probe
PC 2700
-
Your all-in-one solution for multi-parameter research work in the lab! The new PC 2700 is accurate, reliable and intuitive with user-friendly functions. Meter comes with a multi-data screen that includes Temperature, electrode status, calibration points, date and time along with your desired measurement parameter
-
Product
Fire Extinguishers Testing Equipment
-
The circular electrode brush passes easily through the neck of the extinguisher cylinder and then expands to make reliable contact with the lining. Faults are detected by the voltage jumping from the electrode to the earthed shell, causing an alarm to sound. Special electrodes are available specifically for this application.
-
Product
PH Meters
-
* Three reading modes* Smart-Read function. More stable the reading with auto recognition end-point* Cont-Read function. It is clear to read the sample changing in measurement process* Timed-Read function. Auto timed to store the reading* Auto upgrade hardware* Power-off protection, protect your data* Remind the electrode performance and calibration.
-
Product
pH 450 Waterproof Portable Meter
-
Backlit, rugged waterproof meter is ideal for any environment!*Intuitive, user-friendly icons — electrode status displays pH slope*Grip-Clip™ electrode holder quickly and easily secures electrode to side of beaker or container*USB or RS-232 output for up to 500 data sets*Extended battery life or optional universal power adapter*Built-in stand with wall mount option allows for easy benchtop measurement or storage
-
Product
Decay Accessory Set
PGB-745
-
- Designed for measuring charge movement and decay time of ESD controlled materials- The set consists of two stainless steel electrodes and two very high resistance test leads selected for this application- The high resistance leads minimize leakage during the test cycle and are equipped with male banana plugs
-
Product
Electrodes
-
EGL electrodes have consistently raised the industry standards for reliability and performance since their introduction in 1930.To ensure rigid quality control, all phases of manufacturing are performed in-house, including emission coating, inverter welding shells with lead wires, and sealing and centering the mounts in glass envelopes.
-
Product
Isolation Tester UIP
-
The devices of the UIP (Union Isolations Prüfer) isolation tester series are used to test the pore-free condition of corrosion protection coatings of pipes, vessels or plant system parts. The battery-powered device generates test voltages between 5 kV and 30 kV, which are applied to the grounded test object via test electrodes. The location of a defect is signalized by a spark-over with an additional audible warning.
-
Product
3D inversion geophysical software for Resistivity and Induced Polarization Data
RES3DINV
-
This program is designed to invert data collected with a rectangular grid of electrodes. The arrays supported include the pole-pole, pole-dipole, inline dipole-dipole, equatorial dipole-dipole and Wenner-Schlumberger. The RES3DINV program uses the smoothness-constrained least-squares inversion technique to produce a 3D model of the subsurface from the apparent resistivity data alone.
-
Product
Handheld Water Quality Meters
LAQUA PC210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Ocean and River Instruments
RINKO W
-
Rinko W is an autonomously deployable data logger for long-term DO measurements. In order to protect the sensing foil against accumulating bio-fouling, the instrument has a mechanical wiper to sweep the optical window. The optical sensor does not have a membrane neither electrolytes, thus, it need less maintenance than electrode or galvanic sensors.
-
Product
pHTestr® 50 Waterproof Pocket pH Tester,
Premium 50 Series
-
The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.
-
Product
IDA Electrodes
-
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
Product
Potentiostats
-
A potentiostat is a device that controls the potential between a pair of electrodes while measuring the resulting current flow. The resulting electrochemical plot is then used to determine various parameters relevant to the experiment.
-
Product
Digital Tank Test Kit
4109
-
The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `
-
Product
Dielectric/Conductivity Sensor
Micro-VariconTM
-
The Micro-Varicon sensor is a miniature, thin, flexible dielectric sensor designedfor cost-sensitive use where space is limited. The electrode array is patterned on apolyimide substrate, and the Micro-Varicon sensor can be supplied with or withoutTeflon insulated leads.
-
Product
Static Generation
Charging Electrodes
-
Fraser Anti-Static Techniques Ltd
Provide a safe, controllable, reliable and cost-effective method of applying static charge for temporary adhesion.
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
-
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
Product
Optical Emission Spectrometry
-
Involves applying electrical energy in the form of spark generated between an electrode and a metal sample, whereby the vaporized atoms are brought to a high energy state within a so-called "discharge plasma".


















