Electrodes
-
product
Gamma Detectors
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
product
Proving Unit & Voltage Tester Kit
DLPK1
Touch electrode for Quick testing of fused leads Optical and acoustic continuity Indication Low battery indication A portable, battery powered Proving Unit for testing Two Pole Voltage Testers up to 690V Continuity Tester for testing: Fuses, Fused test leads etc
-
product
Multichannel Pontentiostats
Arraystat Series
Arraystat instruments are multichannel potentiostats that utilize a common counter electrode. 25 channel potentiostat with common counter-reference electrode for combinatorial chemistry.
-
product
MyoWare 2.0 Muscle Sensor
Using our muscles to control things is the way that most of us are accustomed to doing it. We push buttons, pull levers, move joysticks... but what if we could take the buttons, levers and joysticks out of the equation and control it with our muscles? The MyoWare® 2.0 Muscle Sensor is an Arduino-compatible, all-in-one electromyography (EMG) sensor from Advancer Technologies that allows you to do just that! The MyoWare 2.0 Muscle Sensor has been redesigned from the ground up with a new easy-to-use, compact design and upgraded with the latest and greatest chipset improving sensor performance and reliability. The innovative snap connector system eliminates the need to solder connections for the MyoWare 2.0 ecosystem. It's that easy: stick on a few electrodes (not included), read the output voltage and flex some muscles!
-
product
Fully Automatic Transformer Oil Test Set
OTS-A series
The Motwane Manufacturing Company
OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.
-
product
Solid Electrode Spectrochemical Cell
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
product
Portable Conductivity/TDS Meter with Conductivity electrode
CyberScan CON 11
User Customizable Functions for options: Normalization Temperature, Temperature Coefficient, TDS (Total Dissolved Solids) factor, Cell constant and many more
-
product
Principle Of Optical Emission Spectrometry
Optical emission spectrometry involves applying electrical energy in the form of spark generated between an electrode and a metal sample, whereby the vaporized atoms are brought to a high energy state within a so-called "discharge plasma".
-
product
Open Flanges Test Rig
Flexible cell dimensions: cells of Ø 8 to Ø 80 mm (or square till 70x70 mm) can be successively installed Quick start of experiment: less than 20 minutes to remount a new cell with different dimension, thanks to the simple design without sealing Other SOFC components: the open flanges test rig is also useful for conductivity measurements (electrolyte, electrode material, interconnect etc.) and sealing tests End of broken cells and secure testing: the cell is squeezed by a soft alumina felt that prevents any damages, the excess fuel burns continuously in the alumina felt at the cell edges
-
product
Conductivity Type (P/N) Checker By Contact Thermo-electromotive Force Method (seebek Effect)
PN-12α
*Thermo electrode and cold electrode is mounted detecting part of measuring probes*Possible to check most figure of sample such as single crystalline silicon wafer, bulk, ingot and so on*Please select from 2 types;1) 2 probe ver.(Hot probe, Cold probe),2) 1 probe ver.(Hot & Cold probe)
-
product
Room Temperature Sample Holders
12962A
The 12962A sample holder is designed to allow accurate impedance tests of solid materials to be performed at room temperature. The sample holder consists of two parallel electrodes, one of which is fixed in position and the other which can be moved into contact with the sample by adjustment of a micrometer. The sample holder makes use of guard ring and reference techniques in order to improve accuracy by reducing “fringing” effects at the edge of the sample. The standard electrode provided is 20mm diameter.
-
product
Telurometer
AMRU-200
*The only meter on the market that implements all measurement methods:*Technical method of 2, 3 or 4 poles*Drive method (4/10μs, 8/20μs, 10/350μs).*Double-clamp method without the need for auxiliary electrodes.*Soil resistivity.
-
product
New Resistivity Inversion Software
EarthImager 3D
AGI is proud to introduce the new EarthImager 3D resistivity and IP inversion software. This software inverts resistivity and IP data acquired with electrodes arranged in boreholes and/or on the surface and presents a 3D volume of inverted resistivity data with advanced volume rendering technique. The final resistivity or IP image-volume can be rotated in any orientation, zoomed in and out, and translated to anywhere inside the image window in order to see the volume of interest in detail. Colors representing areas of less interest can be made transparent so that the shape of a pollution plume, for example, can be visible. With EarthImager, 3D resistivity inversion can be as easy as two steps: Read Data and Start Inversion with only a few mouse clicks.
-
product
Insulation & Earth Resistance Testers
KV Hipot Power Test Equipment Co.,Ltd
resistance tester is used to measure the resistance of the earth is called Earth Resistance Tester. All the equipment of the system is grounded through the earth electrode. Unhindered earthing protects electrical equipment and personnel from the fault current.
-
product
Multiplexer
The Ivium Technologies electrochemical multiplexer can work individual cells with 2, 3 and 4 electrodes and a WE2 (BipotentioStat, optional). Each multiplexer has 8 channels and the multiplexer units can be stacked so that up to 64 channels can be controlled sequentially by a single potentiostat.
-
product
Safety Tools Testing
Weshine Electric Manufacturing Co., Ltd
1. The high voltage is extremely spherical and the grounding voltage is annular.2. The grounding electrode is fixed and the high voltage electrode can be electrically driven to move to the left and right.
-
product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196A
The 16196A surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
product
Electrodes
EGL electrodes have consistently raised the industry standards for reliability and performance since their introduction in 1930.To ensure rigid quality control, all phases of manufacturing are performed in-house, including emission coating, inverter welding shells with lead wires, and sealing and centering the mounts in glass envelopes.
-
product
Potassium Pocket Water Quality Meter
LAQUAtwin K-11
HORIBA's unique compact meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop.
-
product
Conductivity Electrode
As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.
-
product
Resistivity Imaging & Sounding System
Syscal Junior Switch
The Syscal Junior is an all-purpose resistivity imaging and sounding system for environmental applications. The system can be supplied as a standard imaging system capable of recording two measurements simultaneously. The second recording channel significantly improves data acquisition time when the instrument is fitted with internal switching board for 24 (Switch-24) 48 (Switch-48) or 72 (Switch-72) electrodes for Electrical Resistivity Tomography (ERT).
-
product
Walking Test System Kit
PGA-710
The PGA-710 Walking Test System is a complete kit designed to perform the walking test per ANSI/ESD STM97.2 and IEC 61340-4-5. The system consist of several devices designed for portability and to perform several different tests which includes measuring the voltage on a person in combination with floor materials and footwear.The kit includes the PGA-710B Data Logger, the PFM-711B Field Meter, CPM-720B Charge Plate Monitor, the PCS-730B Electrostatic Charger, Hand Held Electrode and the Prostat Autoanalysis Software version 2.0.
-
product
Potentiostat
EA163
This modular potentiostat is perfect for cyclic voltammetry and electroanalytical chemistry, and can use two (working and counter), or three (working, auxiliary and reference) electrodes. It can also operate as a galvanostat, ZRA (zero resistance ammeter), and high impedance voltmeter. It must be used together with any e-corder model.
-
product
pH 550 Benchtop pH Meter Kit with Probe, Stand, and pH Buffers
The PH 550 benchtop pH meter features a microprocessor chip which provides automatic temperature compensation, data storage, parameter setup, and Max/Min reading display. The meter offers a pH range from 0 to 14 and a three-point automatic calibration, with the ability to recognize standard buffer solutions (USA or NIST series). The advanced digital processing technology improves meter response time and measuring accuracy. A stable reading display icon appears when the measuring value is stable. The 3-in-1 combination pH electrode measures pH and temperature simultaneously. The compact meter includes a detachable electrode holder and three bottles of pH buffer solution. It has a dustproof and spillproof rating of IP54. Connectors are protected by silicone seal caps.
-
product
Meter with "3-in-1" pH/Temperature Combi Electrode
pH 5+
Multi-Point Calibration (up to 5 points) with Auto-Buffer Recognition - choice of USA, NIST or pure water buffer standards with ±0.01 pH accuracy
-
product
Rectal Probe For Rats (Isolated)
RET-2 ISO
• An isolated sensor (can be used with monitoring equipment where electrical interference from other electrodes may be present).• Reinforced strain relief for applications where probe is in more frequent use.• Smooth ball tip. Stainless steel shaft - '' long, .059'' diameter. Tip diameter .125'', 5 foot lead length. Time constant 0.8 seconds.
-
product
Operando Spectroscopy
The operando cells, designed to interface with certain IR and Raman spectrometers, enable study of electrode surfaces during normal operation. Choose between the "fuel cell" and "solid electrode" configurations. These custom - designed tools can help your research lab understand how materials behave under operation.
-
product
CMAS Analyzers and Field Monitors
Backed by at least one of the 8 corrosion sensor patents wholly owned by Corr Instruments, our nanoCorr analyzers and field monitors are widely used for online and real-time localized and general corrosion monitoring. These ultra-high precision instruments measure extremely low currents in the pico-ampere levels, which can be translated into a corrosion rate as low as a few nanometers per year, in some applications (PDF). Our analyzers and monitors are based on the patented coupled multielectrode array sensor (CMAS) technology which measures the flow of electrons from corroding electrodes to one or more cathodes.
-
product
Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)
HC-300F
HC-300F is connected to a fluoride ion electrode (1009) to detect free fluoride ions in the sample water.(Total fluorine is not detected.) It is suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers.