Electrodes
-
Product
Handheld Water Quality Meters
LAQUA DO220
-
Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsWith real-time clock and date/time stamp for GLP complianceAuto log data; built-in memory can store up to 1000 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmPhono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty
-
Product
Electrosurgery Analyzers
-
Electrosurgery Analyzer is the ESU tester you can depend on for complete preventive maintenance and electrosurgical device safety to completely test these critical functions:* Measures current, voltage and power output.* Tests RF leakage from output to ensure no hazardous currents are present.* Performs Return Electrode Monitoring (REM) tests.* Measures crest factor.* Performs automatic power distribution curve at a wide range of test loads.
-
Product
Starter Electrodes
-
Backed by our commitment to accurate and precise measurement, the OHAUS Starter Series of electrodes are designed to produce exact results time and time again.
-
Product
BOMBARDING A.C. MILLIAMPERES METER
-
A Bombarding A.C. Milliamperes Meter is one of the four instruments essential for proper luminous tube processing. This instrument monitors the level of bombarder current in milliamperes that is generated by the bombarder, through the tube being processed. It is necessary to accurately monitor the current for the tubing and electrode sizes used to ensure that the right amount is applied at the appropriate time. To do otherwise may cause damage to the electrodes, fluorescent coating inside the tube and adversely affect the glass structure.
-
Product
Static Generation
-
Fraser Anti-Static Techniques Ltd
Static generation systems, electrodes and IML accessories for safe, clean and controllable temporary adhesion.
-
Product
Resistivity Meter with Multi Electrode
POLARES
-
Till this moment the use of Electrical Resistivity Tomography (ERT) for geology has always been basically the same since its debut, based on the original vertical Electrical Soundings (VES) principles: applying a continuous current to two stakes inserted into the ground and measuring the corresponding voltage between other two. The applied current and thus the relative tension have always been continuous, with an inversion in polarity for each measure. The new tool POLARES uses an alternate current, instead, sinusoidal type, with an adjustable frequency.
-
Product
Grid Electrode
-
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
Product
Waterproof Handheld Meter with pH electrode
CyberScan PCD 650
-
A Eutech Star Buy! Combining the strengths of all CyberScan 600 series meters, the CyberScan PCD650 is our top-of-the-line waterproof handheld that enables concurrent measurement of pH, conductivity, dissolved oxygen and temperature, all at the same time.
-
Product
Dielectric/Conductivity Sensor
Mini-VariconTM
-
The Mini-Varicon sensor is a thin, flexible dielectric sensor designed for cost-sensitive use with presses, molds, bulk materials or laminates. Patterned on a polyimide substrate, the electrode array is designed to allow a choice of high or low sensitivity, selected by either using the whole sensor or cutting off a portion of the array at a designated line. The Mini-Varicon sensor can be supplied without leads, or with custom-length Teflon-insulated leads attached.
-
Product
Capacitive
VEGACAL
-
In capacitive level measurement, the sensor and the vessel form the two electrodes of a capacitor. Any change in level causes a capacitance change, which is in turn converted into a level signal.
-
Product
Electrostatic Precipitator
-
HIGHVOLT Prüftechnik Dresden GmbH
Electrostatic precipitators are used for clean process and exhaust gases, for example, in the cement and building materials industry, in steel mills, in conventional power plants, and in waste incineration plants. The dust particles are discharged electrostatically charged by a spray electrode, deflected by a DC electric field and deposited on the electrode.
-
Product
pH-Meters
-
Test soil pH, water pH, food pH and more quickly, easily and accurately with a digital pH Meter / pH Tester from PCE Instruments. Whether you’re looking for a compact, pocket, portable, handheld or tabletop pH Meter / pH Tester, you will find the best pH Meter / pH Tester for your application here. PCE Instruments also offers optional accessories such as pH Meter / pH Tester certified calibration certificates, oxygen probes and electrode storage solutions.
-
Product
Salinity Testers
-
Labodam pocket salinity testers are equipped with platinum sensors, providing fast and reliable results measuring the salinity of water and other low and high salt concentrated solutions. Equipped with replaceable electrodes, helping to reduce maintenance cost.
-
Product
Plasma Processing Systems
PlasmaSTAR
-
The PlasmaSTAR® Series of Plasma Processing Systems from Axic, Inc. defines a new concept in barrel plasma processing. The systems are based on a modular design concept. Starting with a universal base unit, multiple electrode modules are available for easy insertion into the base unit. You will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma.
-
Product
Bottom Electrode SMD Test Fixture
16197A
-
The 16197A is designed for impedance evaluations of bottom electrode SMDs. It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements. The Keysight 16197A supports various SMD sizes, as small as 1005 (mm)/0402 (inch) and as large as 3225 (mm)/1210 (inch). Accommodation of the 0603 (mm)/0201 (inch) size is available with option 001.
-
Product
Single Cell Hardware
-
A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).
-
Product
Earth Resistance Clamp Meters
-
Precision Mastech Enterprises Co.
Specialized, non-intrusive electrical testing tools designed to measure grounding system resistance without disconnecting the ground rod or using auxiliary electrodes.
-
Product
Coupled Multielectrode Array Sensor (CMAS) Probes
-
CMAS probes are made from user-specified sensing materials, including carbon steels, stainless steels, and nickel-, aluminum-, and copper-based alloys. They can also be made from customer supplied materials that have the same microstructure/heat treatment as the system component materials to be monitored. The size of the sensing electrode varies from 0.1 to 3 mm (0.004" to 0.12") in diameter, depending on the application. Typical numbers of electrodes in a CMAS probe are 9, 16 or 25 for online corrosion monitoring and vary from 8 to 100 for laboratory corrosion and electrochemical studies.
-
Product
Analog Tank Test Kit
4108
-
The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.
-
Product
Bridge Decking Testing Equipment
-
The testing process can detect blow holes, inclusions or thin areas in 'sprayed-type' membranes. Because the concrete contains a small amount of water, it is electrically conductive and a DC Pinhole Detector can be used to create a high voltage which is passed over the surface by the use of a brush electrode. An alarm will sound to identify any small defects which can be rectified so that the integrity of the coating can be verified.
-
Product
Synchronous GPS Based I/O Controller & Interrupter
interX
-
interX was originally developed as a measurement instrument for industrial and trunk pipeline anodic or cathodic protection systems. interX allows facilitate measurement of galvanic parameters (instant-off polarized potentials, pipe-to-soil potential) across a wide range of timing cycles. It is used to make synchronous disconnect and reconnect of protection electrodes (anode or cathode) or rectifier's from/to buried underground pipeline to perform measurements.
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
Product
pHTestr® 10 Waterproof BNC Pocket pH Tester
-
Simply choose the electrode best suited for your application, connect the pHTestr BNC 10, calibrate, and measure. Change electrodes to suit your application without having to purchase another meter. Order electrodes separately. Large display and tactile keypad allow for easy calibration along with USA and NIST auto-buffer recognition. Hold function freezes reading on the display for easy recording. Additional features include Valox® sensor housing, self-diagnostic error messages, a battery-life indicator, and an auto-off function to maximize battery life.
-
Product
Conductivity Transmitter
DO9766T-R1
-
output of a conductivity electrode with temperature compensation into a 4÷20 mA signal.
-
Product
Electrochemistry Research Equipment
-
Our electrochemical equipment will help your group achieve laboratory and research goals. The best-selling EZstat Pro potentiostat/galvanostat can run cyclic voltammetry, electrochemical impedance spectroscopy (EIS), battery tests, and high speed galvanostatic intermittent titration technique (GITT). The EZstat HV potentiostat delivers up to 1 amp at 25 volts. The Powerstat comes in two configurations (5 amp vs 20 amp). The Duostat bipotentiostat can operate rotating ring-disk electrode experiments. The Arraystat and ArrayPGstat feature multichannel operation with different customizable options (current range, number of channels, etc.).
-
Product
Charge Plate Monitor
-
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
Product
Earth Leakage Relay
-
Nippen Electrical Instruments Co.
NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.
-
Product
Cell Production
-
JRT Photovoltaics GmbH & Co. KG
The production of lithium-ion cell batteries includes the three main process stages of electrode production, cell assembly and formation and aging. Automation is a critical factor for success, particularly in the process stage of cell assembly.
-
Product
Eurostat Turnstiles
-
For companies who need to ensure that the operators cannot enter the EPA unless their wrist straps and footwear are compliant every day• The turnstiles comply with ANSI/ESD S20/20 specification and ISO standards record keeping requirements • Both ESD safe shoes are tested separately through measuring electrodes, installed in the contact mat.• This system tests operators quickly (≤ 3 sec) and automatically and generate reports for the ESD coordinator• Communication with a server for traceability (Operator ID, Time & Date, Test values etc…)• LCD screen showing real time measurement• Keypad• Hygrometry measurement• Choice of measuring ranges and system calibration directly with the software• HID Wiegand interface, compatible to any HID card format
-
Product
Dielectric Material Test Fixture
16453A
-
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.





























