Electrodes
-
product
pHTestr® 50 Waterproof Pocket pH Tester,
Premium 50 Series
The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.
-
product
Resistance Welding
Resistance welding is a method in which the welding works are heated by resistance heat generated by sandwiching the welding workpieces with welding electrodes, passing current through them, and the metal is welded while pressurizing the works.A resistance welding machine composed of welding power supply, a weld head and an electrode. The welding power supply controls a welding current,the weld head exerts a pressure on the material to weld and the electrode provides welding current and pressurization force to the part under welding. We have been providing various kinds of welding power supplies and welding heads to meet these requirements.
-
product
Syscal Pro switch
The Syscal Pro is an all-in-one multinode resistivity and induce polarization imaging system for environmental and engineering geophysical studies. The Syscal Pro gathers a 10 channels receiver and a 250W, 2000Vpp internal transmitter which make it the more powerful system of the Syscal range. This system allows to perform up to 10 measurements at a time and its switching board allow to work for 48 (Switch-48) up to 120 (Switch-120) electrodes.
-
product
Sensor Products: Weld Force Gage
90061
Model 90061 is a self-contained, portable measurement system which allows auditing of the pinch force generated between the electrodes of resistance spot welders. Resistance welding uses a pair of electrodes to clamp two base metals firmly together prior to and during application of electrical current. Poorly clamped parts result in a defective joint. A correctly clamped assembly aids in reducing the resistance in the joint and allows the current flow to properly heat the base metals to weld the part.
-
product
Bottom Electrode SMD Test Fixture
16197A
The 16197A is designed for impedance evaluations of bottom electrode SMDs. It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements. The Keysight 16197A supports various SMD sizes, as small as 1005 (mm)/0402 (inch) and as large as 3225 (mm)/1210 (inch). Accommodation of the 0603 (mm)/0201 (inch) size is available with option 001.
-
product
Meter With pH Electrode, ATC Probe
pH 2700
Oversize screen with large fonts yet compact – the new Eutech pH 2700 offers an easy to read screen that says more! View pH or ORP readings, with temperature, electrode status, calibration points, date and time all at once!
-
product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196B
The 16196B surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results, reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement. Now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
product
Wood Moisture Meter
Using the principle of electrical resistance, pin-type meters use the board as an element in a circuit by driving two pins or electrodes into it. This method works because moisture conducts electricity well and dry wood is an effective insulator.
-
product
Radiometer Analytical Probes
Radiometer Analytical develops and manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes and conductivity cells - for every application and budget.
-
product
Electrode Measurement Meter
Ion 700
Ion-selective electrode measurement has never been this easy – or economical! The Ion 700 measures and records up to 100 data points with 0.01 resolution.
-
product
Electrochemical Analyzer
EC Epsilon EClipse
The Epsilon EClipse™ is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. It comes with software that enables the most popular electrochemical techniques such as cyclic voltammetry, chronoamperometry, and chronopotentiometry (select Techniques below for a more complete list). The Basic Plus software can be purchased to enable pulsed voltammetry and stripping voltammetry techniques.
-
product
Conductivity Sensors
Conductivity sensors measure the specific conductance of liquid processes. The specific conductance is directly related to the presence of ionic species and their concentration. Barben Analytical offers a full range of two electrode and four electrode contacting conductivity sensors for a variety of industrial measurement applications.
-
product
Marine Logging System
SuperSting Marine
The SuperSting Marine continuously records and stores data from a GPS receiver. Current is injected every 3 seconds and 8 apparent resistivity values representing 8 depth levels are read for each current injection. Depth of penetration depends on length of the cable and array type. Typically you will see down to aproximately 20% of the electrode spread length.
-
product
Long Term Test Kit
When long term electro-chemical tests (>1000 hours) are run to monitor the cell degradation at the cathode for example, it is important to avoid any contaminant in the gas flow rate.Inconel 601 flange equipped with alumina housing and alumina tube to feed the gas to the electrode during long term test (>1000 h)Typical poisoning is coming from the chromium contained in the steel tubing. The volatile chromium species (Cr6+) will flow into the cathode (with the air) and thanks to the intake of electrons at the electrode, the chromium ion will transform to chromium oxide and be deposited at the cathode triple point. In such a case, the long term test kit is used. The Inconel 601 flange is equipped with an alumina housing (>96 % Al2O3) and the air (or other gas) is led through an alumina tube. The long term test kit is fully compatible with other functionalities proposed with the Open Flanges™ test Set-Up as the integrated steamer or the small pellet test kit. The long term test kit can be implemented on the fuel, on the air or on both sides.
-
product
Dielectric Test Fixture
16451B
The 16451B is used to evaluate the dielectric constant of solid dielectric materials accurately, and complies with ASTM D150. The 16451B employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixture.
-
product
Synchronous GPS Based I/O Controller & Interrupter
interX
interX was originally developed as a measurement instrument for industrial and trunk pipeline anodic or cathodic protection systems. interX allows facilitate measurement of galvanic parameters (instant-off polarized potentials, pipe-to-soil potential) across a wide range of timing cycles. It is used to make synchronous disconnect and reconnect of protection electrodes (anode or cathode) or rectifier's from/to buried underground pipeline to perform measurements.
-
product
2D Geophysical Inversion Software for Resistivity and Induced Polarization Data
RES2DINV
RES2DINV software is designed to interpolate and interpret field data of electrical geophysical prospecting (2D sounding) of electrical resistivity (conductivity) and induced polarization. The inversion of the resistivity and IP data is conducted by least-square method involving finite-element and finite-difference methods. The software can handle data from any electrode array, including Wenner (a, b, g), dipole-dipole, inline pole-dipole, pole-pole, Wenner-Schlumberger, equatorial pole-dipole and non-conventional arrays. Interpolate data from land, under water, and cross-borehole surveys. Easy data conversion from the most popular geophysical instruments including ABEM Lund, Syskal, AGI, PASI, IRIS, SCITREX, etc.
-
product
SpectrOil M/F-W Fuel Analyzer
SpectrOil M
The SpectrOil M/F-W is a compact, rugged and easy to use fuel analysis spectrometer. It is designed specifically for the analysis of ash-forming contaminants in fuel such as sodium, potassium and vanadium that cause corrosion or deposits at turbine operating temperatures. It measures trace quantities of dissolved or suspended contaminant particles in a fuel sample using the time-tested and reliable rotating disc electrode (RDE) technique.
-
product
Continuous LPR Corrosion Meter
MS2001L
The MS2001L is a microprocessor-based, field-mountable corrosion rate meter. This versatile instrument measures the instantaneous corrosion rate and electrochemical current between the electrodes of any standard 2-electrode linear polarization resistance (LPR) probe. Corrosion rate is displayed on the LCD display.
-
product
Parallel Electrode SMD Test Fixture
16192A
The 16192A test fixture is designed for impedance evaluations of side electrode SMD components. The minimum SMD size that this fixture is adapted to evaluate is 1(L)[mm].
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Scanning Electro-chemical Microscope
920D
The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.
-
product
Flame Ionization Detector
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
product
Reference Electrode Kit
SC-4
The Model SC-4 Sliver-Silver/Chloride kit come complete with everything necessary to conduct field tests both ON SHORE and OFF SHORE.
-
product
Counter Electrodes
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
product
PH Meters
Shenzhen Graigar Technology Co.,Ltd.
A pH Meter is a device used for potentiometrically measuring the pH, which is either the concentration or the activity of hydrogen ions, of an aqueous solution. It usually has a glass electrode plus a calomel reference electrode, or a combination electrode.
-
product
Bridge Decking Testing Equipment
The testing process can detect blow holes, inclusions or thin areas in 'sprayed-type' membranes. Because the concrete contains a small amount of water, it is electrically conductive and a DC Pinhole Detector can be used to create a high voltage which is passed over the surface by the use of a brush electrode. An alarm will sound to identify any small defects which can be rectified so that the integrity of the coating can be verified.
-
product
Bluetooth® Enabled ORP/REDOX & Temperature Pen
UltrapenX2™ PTBT3
*Accuracy of ± 10 mV ORP*3 Calibration Options with Automatic Solution Recognition*Automatic Temperature Compensation in Calibration Mode*99.9% Pure Platinum Electrode*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Powered by One N Type Battery (Included)*Waterproof
-
product
pHTestr® 50 Waterproof Pocket pH Tester,
The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.
-
product
Meter With pH Electrode, Conductivity Probe
PC 2700
Your all-in-one solution for multi-parameter research work in the lab! The new PC 2700 is accurate, reliable and intuitive with user-friendly functions. Meter comes with a multi-data screen that includes Temperature, electrode status, calibration points, date and time along with your desired measurement parameter