Electrodes
-
product
Salinity Testers
Labodam pocket salinity testers are equipped with platinum sensors, providing fast and reliable results measuring the salinity of water and other low and high salt concentrated solutions. Equipped with replaceable electrodes, helping to reduce maintenance cost.
-
product
SMD Array Type LCR Test Fixture
16034H
The 16034H is designed for impedance evaluations of array-type SMD.The minimum SMD size that this fixture is adapted to evaluate is 1.6(L)x0.8(W)[mm]. Since the tip of the measurement electrodes are very thin and the device holder is extremely flat, the device can be shifted and the measurement electrodes can contact each of the elements of the array-type component.
-
product
Concentric Ring Set
PRF-911
- Measures surface resistance per ANSI/ESD STM11.11- Measures volume resistance per ANSI/ESD STM11.12- Meets the requirements of IEC 61340-2-3- Approximates surface & volume resistivity per ASTM D-257- Incorporates a spring loaded, self-aligning center electrode feature to reduce calibration frequency- Includes an insulated and metal dual test bed- Designed to work with a wide range resistance meter and one 5 lb. electrode- Certificate of calibration traceable to NIST included
-
product
Bulk Acoustic Wave Technology
BAW
Macom Technology Solutions Holdings Inc.
MACOM’s BAW product portfolio is ideal for high performance Industrial, Aerospace, Defense, and Communications applications that require critical frequency filtering. Our high-performance RF filters enable our customers manage signal integrity in the 1 to 6 GHz frequency range. Bulk Acoustic Wave Resonators consist of two metal electrodes above and below a layer of a piezoelectric material. The piezoelectric material converts an electrical signal to a mechanical signal and vice versa. The metal electrodes provide the connections to/from the piezo material. The frequency at which resonance occurs depends on the thickness of the combined metal-piezo-metal stack. Advances in thin-film piezoelectric fabrication have enabled BAW resonators to meet RF filtering challenges up to 6000 MHz using standard MEMS fabrication process. High-performance BAW resonators-based RF filters are made of piezoelectric material having high Q-factor (>3000) and high coupling coefficient. Currently, no competitive technology provides the same high performance for RF filter applications when compared to BAW resonator-based RF filter up to 6000 MHz for the same size and cost.
-
product
Static Generation
Fraser Anti-Static Techniques Ltd
Static generation systems, electrodes and IML accessories for safe, clean and controllable temporary adhesion.
-
product
pH 2700 Benchtop Meters
Oakton 2700 meters meet GLP requirements - meters stamp all calibration and stored data with time/date. Nonvolatile memory stores up to 500 data sets to simplify documenting large volumes of pH or mV measurements. Meters automatically calculate and display electrode slope and offset - ideal for checking electrode quality. Order RS-232 and optional RS-232 to USB adapter separately. Advanced set-up options allow for a large degree of user customization. Datalogging intervals can be programmed into the meter for convenient continuous monitoring.
-
product
Universal Converter
C8000
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
product
Model N8: Narrow Materials Moisture Meter
MRC001948
Designed for flat, curved, smooth, or rough surfaces such as cones or beams of yarn, rolls or stacks of cloth, and more. Electrode covers an area of 1 - 1/4 x 3 inches and penetrates 1/2 inch into the product.
-
product
Plug and Switch Testing
Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right.
-
product
Handheld Water Quality Meters
LAQUA PC210
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196C
The 16196C surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
product
Working Electrodes for Flow Cell
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
product
Grid Electrode
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
product
Field-installation Type pH Meter (Four-Wire Transmission)
HP-200
HP-200 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
product
Spring Clip Fixture
16092A
Use this test fixture with parallel electrodes for impedance evaluation of both lead and SMD components.
-
product
Reference Electrodes
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
product
Single Channel Potentiostats
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
product
Multi-Potentiostat
1000C
The model 1000B series is a computerized 8 channel potentiostat. The system contains a digital function generator, multiplexed data acquisition circuitry, and a multi-potentiostat that can work with eight independent cells or eight working electrodes in the same solution with common reference and counter electrodes. The potential control range is 10 V for all channels, which can be set at independent potentials or the same potential as the primary channel, so that they can sweep or step potentials together with the primary channel.
-
product
Multi-probe for Ammonium and/or Nitrate
S470
S470 is a complete family of Ion selective electrodes (ISE) probes suitable for monitoring the performance of the ammonium ion (as NH4+ or NH4–N) and nitrate ion (as NO3– or NO3–N) in a liquid matrix.
-
product
Potentiostats and Galvanostats
Potentiostats are feedback amplifiers which control an electrode to a certain potential with respect to a reference electrode. They may control microelectrodes in animal or herbal cells, and the current is measured in picoamperes, or large-area electrodes in batteries or production cells.
-
product
Double Sheet / Splice Inspection
Leuze electronic GmbH + Co. KG
Double-sheet control sensors enable the reliable differentiation between one or more layers of very thin objects made of different materials. This allows, for example, single-layer paper sheets to be reliably pulled in or individual electrodes to be stacked for the production of a battery cell. Different operating principles, based on ultrasonics and capacitive sensors, cover the range of materials for different applications. Sensors for splice inspection detect desired and random splices in paper webs independent of the surface color and material properties.
-
product
Single Cell Hardware
A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).
-
product
Rotating Ring Disk Electrode
RRDE-3A
RRDE-3A is a constant rotation system for use in hydrodynamic modulation rotating ring disk electrochemistry. A 7 mm diameter electrode with short stainless steel shaft provides for a miniature and concentric circle electrode system that is capable for highly accurate rotation and modulation even at radial modulation rates or wave forms.
-
product
Earth Tester
TAURUS PRECIOHM ET
The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.
-
product
Miniature Two-Point Probe Set
PRF-922B
The PRF-922B Miniature Two Point probe accurately measures point-to-point resistance of small areas. Like Prostat's PRF-912B Miniature Concentric Ring, the PRF-922B is capable of measurements up to 1.0x1012 ohms. Built-in distance stops provide consistent electrode to sample pressure for developing repeatable measurements. Use the PRF-922B to measure small material samples, hard to assess molded areas, edges of parts, tray or tape cells and other very small objects and surfaces. The assembly is supplied with replaceable conductive electrode covers to enhance contact resistance on irregular surfaces and composition materials. Thus, measurements may be made with either the gold plated electrode contacts, or via conductive rubber covers.
-
product
Flat Carbon Sensor Conductivity meter
HE-960LF / FS-09F-1/2
It is effective to keep the dilution of Slurry constant. Maintaining an appropriate conductivity value contributes to process stability in the wafer polishing process. Even highly viscous sample liquids such as CMP Slurry can be measured without problems because they use a sensor structure that reduces the risk of the sample liquid sticking to the electrodes. In addition, the sensor is made of a wetted material with excellent chemical resistance, which meets the cleanliness requirements of semiconductor processes. In addition to the above, it can also be used for introduction at the semiconductor process development stage and conductivity control of special chemicals.
-
product
pH / mV Transmitter
DO9403T-R1
The DO9403T-R1 pH transmitter converts the output of a pH electrode, with temperature compensation, into a 4÷20 mA signal.
-
product
Electrostatic Precipitator
HIGHVOLT Prüftechnik Dresden GmbH
Electrostatic precipitators are used for clean process and exhaust gases, for example, in the cement and building materials industry, in steel mills, in conventional power plants, and in waste incineration plants. The dust particles are discharged electrostatically charged by a spray electrode, deflected by a DC electric field and deposited on the electrode.
-
product
Earth Resistance Tester
PeakTech Prüf- und Messtechnik GmbH
A Rugged sealed digital earth tester is built with all the protection you need for outdoor use. The instrument is suitable for the testing of single earth electrodes such as lightning conductors and other small earthing systems according to VDE 0413. The resistance of conductors such as continuity and conduit coupling joints can also be measured. Two-terminal operation measurement, which reduces the accuracy, can also be done by shorting P and C terminals. It has an advanced circuit design that permits the instrument to operate with the minimum influence from earth voltage and earth resistance of the auxiliary spikes.
-
product
pH/ORP Wet-Tap
3719
The Signet 3719 pH/ORP Wet-Tap allows installation and removal of pH or ORP electrodes, even under process pressure, without the need for process shutdown during routine electrode maintenance and calibration. Automatic process isolation is achieved during electrode retraction with a double O-ring seal on a unique and compact retraction assembly; no separate valve is required.