Light Choppers
Intercept current or beams of radiation on a periodic basis.
See Also: Light Sources, Optical Heads
-
Product
Light Source
UVF-205S
-
By use of the light guide with the quartz sensor fiber, feed-back control and monitoring of UV irradiation intensity is possible. Also setting of UV intensity and meaurement by personal computer is possible
-
Product
Light and Energy Meter
Model 656
-
OAI Model 656 Meter is designed for use with all mask aligners and flood exposure systems. For over 45 years, OAI is a world leader in UV Light & Energy Measurement Instrumentation used for reliable accurate calibrated control of the photolithography processes in the Semiconductor, MEMS, Wafer Packaging and Wafer Bumping Industries.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1H-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.48 (14.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-62J-2
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Small ROV Light Series
LED-B-Series
-
The Teledyne Bowtech LED-B-SERIES light is designed for use on small ROVs, with favourable physical characteristics of 0.05kg weight and measuring only 54mm in length and a maximum diameter of 31mm, there is no limit to where this light can fit.
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25V-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.83 (24.00) - 2.00 (57.00) Bead Probe
BTP-1HF-2
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25H-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
INTERIOR LIGHTING
-
Our ColourFlow fixtures are suitable for different types of indoor lighting, from accent lighting to colour-lighting entire spaces with ceiling heights of more than 18 metres. Some applications are architectural lighting, ambience lighting in hotels, restaurants and bars, theatre lighting or (accent) lighting for shops. The possibilities are endless with the ColourFlow RGBW and RGBA recessed, surface-mounted, pendant and track fixtures.
-
Product
Light Flicker Meter
LiFli
-
The LiFli light flicker meter enables fast evaluation of light sources on the flickering part (flicker / flicker). Especially in the case of LED lamps, the flicker portion can be determined only by one measurement, since it is in the range of 0% to 100% for these luminous means.Audio features enable the flicker to be reproduced acoustically. A voltage output for further analysis by means of oscilloscope or voltage analyzer is available.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-1I8-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1B-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Miniature Rotating Optical Choppers
350C and 350CD
-
Model 350 is a high stability variable frequency optical chopper. The basic system consists of a control unit and a chopping head. It is supplied with four chemically blacked 30 mm diameter discs. These discs are of 2, 4, 10 and 40 slots and allow operation over the frequency range 10 Hz to 10 kHz.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1L-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light Source Measurement Products
-
Xinye Optoelectronic Engineering Co.,Ltd.
Light Source Measurement Products by Light Source Measurement Products
-
Product
Light 4-Axis Motion Control Universal PCI Card
PCI-1245L
-
Encoder input is 4 MHz for 4xAB mode, 1 MHz for CW/CCW modePulse output up to 1 Mpps and the output type can be switched to differential or single-end by jumper settingSupports 2 axis linear interpolationSupports T/S-curveSupports speed overrideHardware emergency inputWatchdog timerSupports programmable acceleration/deceleration rateProgrammable interruptRDY dedicated input channels & SVON/ERC dedicated output channels are switchable for general input and output purposes
-
Product
Light Meter
LI-250A
-
The LI-250A is a portable meter that displays the output from any LI-COR light sensor that has a cable terminated with a BNC connector. It shows instantaneous values or 15-second averages of values from a sensor.
-
Product
White Light LED Illumination System
pE-300lite
-
CoolLED's pE-300liteis a simple white light LED illumination system that offers intense, broad-spectrum LED illumination for imaging most common fluorescent stains. The pE-300lite Light Source can be fitted directly to the microscope or specified with a liquid light guide. The system is a mercury-free alternative that is safer, more controllable, and repeatable than conventional high-pressure gas discharge illuminators. Spectral coverage is from the UV (DAPI excitation) to the Red region (Cy5 excitation). The system is perfect for hospital and regular research laboratory environments and is affordable within consumables budgets.
-
Product
Light 0.60 (17.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-72I15-2
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Safety Relay Unit for PNP Output (Equivalent) Type Light Curtain
SF-AC
-
Panasonic Industrial Devices Sales Company of America
Safety Relay Unit compatible up to control Category 4. This device incorporates power supply terminals and synchronization line terminals for the Light Curtain, so terminal blocks are not required.
-
Product
Portable Spectrophotometers For Light Transmission
-
Portable and benchtop spectrophotometers for measuring light transmission in the full visible range in-situ. Due to the innovative approach of mutual correction, these measurements are also possible in ambient light.
-
Product
Handheld Fiber Optic Light Source
-
Anfkom International Co.,Limited
3109 optical light source can provide 1 to 4 output wavelengths to meet specific requirements,including the 650nm red source and the 1310/1550nm wavelengths for single mode fiber or the 850/1300nm wavelengths for multimode fiber,as well as other wavelengths according to customer needs.Together with the 3208 optical power meter, it is a perfect solution for the fiber optic network characterization.
-
Product
Robust Safety Light Curtain [Category4 PLe SIL3]
SF4B-□G Ver.2
-
Panasonic Industrial Devices Sales Company of America
SF4B-G Safety Light Curtains, Type 4, PLe - Robust Design
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25T-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light Meters
-
These Handheld Light meters are compact for keeping on hand in the field. Models are available with a Thermocouple input for temperature measurement. Units with Data Logging are available
-
Product
LED Light Measurement System
-
RayClouds Photoelectric Technology Co.,Ltd.
The LED optical measurement system includes Blue Light Analyzer, Glare Analyzer, LED Light Intensity Measurement, LED Goniophotometer, Lighting Electrical Measurement System, LED LightBar Measurement System, LED Photochromic Tester.
-
Product
Light Tach Kit
-
When taking vibration measurements on rotating machinery, it is crucial that you record tachometer pulses along with vibration data. A photoelectric sensor along with reflective tape that is attached to the rotating element will provide these speed pulses for data analysis.
-
Product
Optical Light Source
CARY-LS300B
-
The CARY-LS300B optical light source provide 1310/1490/1550 nm three outputwavelengths to meet specific application requirements. It is a idea solution for the fiberoptic network characterization, out-door network construction inspection and lab application.