Ionizing
Neutralize static charge.
-
product
Radius Radiation Probe
Hawk Radius®
The Hawk® Radius is a ruggedized solution for monitoring both ambient and elevated levels of ionizing radiation. Like a Hawk with its remarkable vision, the Hawk Radius Probe “sees” things that other probes cannot. The high sensitivity weatherized pancake sensor can provide early warning of changing ambient radiation conditions, while the energy compensated detector can accurately report penetrating gamma radiation dose rate at elevated levels. Radius probes are typically deployed as part of an environmental radiation monitoring program, or for safety and security systems. In its standard configuration the probe detects beta, low energy gamma and x-radiation with one channel and energy compensated penetrating gamma radiation levels with a second channel. It can be configured to detect alpha radiation as well. The Hawk® Radius has been deployed worldwide in demanding conditions for protecting communities and collecting environmental radiation data. It can be deployed easily and requires minimum maintenance. The Radius is compatible with Medcomʻs GeigerLink adapter and the IMI Gateway App for use with personal computers. It can also be used with most data loggers including popular Campbell Scientific models.
-
product
Ionizers / Active Oxygen Module (Ozonizers)
Ionizer and ozonizer modules utilize high voltages to ionize/ozonize air molecules. They enable air purification, bacteria removal, deodorization, static charge elimination, electrostatic charging and more, and are widely used in air conditioners, air purifiers, refrigerators, washing machines and other products.
-
product
WINSTAT
WINSTAT is an air ionizer developed for the purpose of eliminating static for every industries. As a wide range of product types is offered, the device can be used for various kinds of applications, including the desktop use and for the line use, etc.
-
product
Professional Floor Certification Kit
PFC-252
The PFC-252 includes Prostat's PRS-812 Resistance System Set with modified 5 pound conductive rubber electrodes and Prostat’s Cable Spacers for exact measurements. The PRS-812 wide range resistance system can take measurements at 10 and 100 volts with accuracy within ±5%. Also included is the PFK-100 Field Meter Set. The PFK-100 set includes Prostat's unique PFM-711A dual range field meter, CPM-720A charged plate monitor assembly and PCS-730 ±1 kv charging source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel.
-
product
Charge Plate Monitors
Our easy-to-use charge plate monitors allow you to accurately evaluate air ionization systems used to neutralize static charge accumulation. Benefit from our economical solutions and products that offer onboard data storage to automate ionization system testing.
-
product
Radiation Microdosimeters
Teledyne e2v HiRel Microdosimeter is a compact hybrid microcircuit which directly measures total ionizing dose (TID) absorbed by an internal silicon test mass. The test mass simulates silicon die of integrated circuits on-board a host spacecraft in critical mission payloads and subsystems. By accurately measuring the energy absorbed from electrons, protons, and gamma rays, an estimate of the dose absorbed by other electronic devices on the same vehicle can be made. The Microdosimeter can operate from a wide range of input voltages. The accumulated dose is presented to three dc linear outputs and one pseudo-logarithmic output giving a dose resolution of 14 µrads and a measurement range up to 40 krads. These outputs are intended to be directly connected to most analog-to-digital converters (ADCs) or spacecraft housekeeping analog inputs (0-5 V range), which makes minimal demands on the host vehicle. The Microdosimeter incorporates a test function to allow electrical testing of the hybrid without the need for a radiation source.
-
product
Autoanalysis System Set
PGA-710B
The PGA-710B is a unique electrostatic data analysis device for use with Prostat's PFK-100B Field Meter and Charge Plate Monitor kit. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions.
-
product
Charge Plate Monitor
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
product
Ionizers
ESD
Electrostatic discharge (ESD) is the release of static electricity when two objects come static control ESD IT-7000 Tabtop ionizerinto contact. Familiar examples of ESD include the shock we receive when we walk across a carpet and touch a metal door knob and the static electricity we feel after drying clothes in a clothes dryer. A more extreme example of ESD is a lightening bolt. While most ESD events are harmless, it can be an expensive problem in many industrial environments.
-
product
Ionization Test Set
PFK-105
- Ionization Test Kit for Measuring Offset Voltage and Discharge Times- Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Charger and Decay Timer- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Evaluate Ionizers and Packaging Materials- Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740B as one- Molded Carrying Case with Foam Insert Included
-
product
Electrostatic Fieldmeter
Model 775
The pocket-sized Simco-Ion Model 775 Handheld Electrostatic Fieldmeter is designed to locate and measure static charge potentials on product, people, equipment and packaging. The Model 775 Fieldmeter uses a non-contacting, chopper stabilized field sensor and a ranging light mechanism to ensure correct measurements of electrostatic fields in all areas—even those using air ionization.
-
product
Charged Plate Monitor
Model 280A
Simco-Ion’s Model 280A incorporates enhanced circuitry that enables it to more accurately measure the performance of high frequency AC ionizers, as well as pulsed DC ionizers and steady-state DC ionizers. The Model 280A can be used as a portable CPM and is capable for of up to 6 hours of operation on the internal battery before recharge.
-
product
Static Meters
ETS static meters are offer accurate detection and measurement of static electricity found in the manufacture and handling of electronic, paper, plastic, textile, food, chemical, biomedical, and pharmaceutical products. In addition, these meters are invaluable for use in computer rooms, cleanrooms, hazardous environments, hospitals, and other locations that require the measurement of electrostatic fields. Chopper-stabilized models enable measurements in ionized environments.
-
product
Digital Static Field Meter
Model 715B
- Assess electrostatic fields or charge on objects- Measures up to ±19.99 kV at a distance of 1 inch- Accuracy of <±5% in both normal and ionized environments- Uses a chopper stabilized sensor- LED ranging lights for positioning the meter at the right distance- Zero function allows the display to be adjusted to zero (0)- Hold feature to lock the reading on the display- Low battery indicator on the display- 1-year limited warranty
-
product
Closed-loop Ionizer Controllers For Multichannel Voltage Detection
Novx 3352/3362
Simco-Ion’s Novx brand of Passive (Model 3352) and Active (Model 3362) Multi-fan Closed-loop Ionizer Controllers provide the capability to simultaneously detect, measure, record and monitor electrostatic voltages in multiple locations. The versatile antennas used with these systems allow their use in a variety of applications including monitoring sensitive workstations, in-tool voltages, or ionizer performance with the option of closed-loop control to select ionizer products.
-
product
Analytical Balaneces
AT-R Series
Basic Model with Improved Convenience.*Freely set responsiveness or stability*Connect with a computer via USB or RS232C*Perform stable measurements in combination with an ionizer
-
product
GC/MS CI , CI/NCI And SMCI Measurement
CI is a softer ionization method than EI, fragmentation is less likely to occur, so molecular weight information is more readily obtained. Negative chemical ionization (NCI) or negative ion chemical ionization (NICI) enables selectively measuring, with ultra high sensitivity, chemical substances with an electron affinity, such as chlorine-based compounds.
-
product
PRODUCTS TESTING
ESD
MicroStat Laboratories -R.E.T.S.
Our ESD test capabilities include resistance, resistivity, electrostatic shielding, charge generation, and charge dissipation. We routinely test flooring materials, packaging, footwear, garments, ionizers and many other ESD control products and materials. We utilize the relevant test methods and standards of the ESD Association, ANSI, ASTM, NFPA, IEST, IEC, AATCC, or our clients’ in-house specifications.
-
product
Ultra Compact Ionizers
ER-V Series
Panasonic Industrial Devices Sales Company of America
The ER-V Ultra-Compact Ionizer offers a new style in charge removal. It uses high frequency AC in an ultra-compact Ionizer for superior static elimination.
-
product
PIEZONIZER
This is an air nozzle ionizer incorporating an ultra-small-size high-voltage transformer without any high-voltage wiring. Since it operates only on DC power input, its wiring has become much simpler.
-
product
Blood Ionized Calcium Pocket Water Quality Meters
LAQUAtwin Ca-11C
Milk fever, or Sub Clinical Hypocalcemia (SCH) is a significant problem with dairy cows. Total calcium levels in the cows’ blood drop after lactation. By measuring the ionized calcium levels of the blood directly cow side, the treatment can start sooner and is more effective. The new LAQUAtwin CA-11C has been specially developed for cow side measurement of ionized calcium in blood. Ionized calcium reflects more accurately the current calcemic blood situation compared to total blood calcium as it equals the free available calcium ions.
-
product
Ionization Kit
PIK-110
The PIK-110 Ionizer Test Kit contains all the instrumentation included in the PFK-101 as well as advanced equipment making it the most comprehensive portable ionizer test equipment available.