Ground
See Also: Earth, Soil, Ground Penetrating Radars
-
product
Breakout Box
T1000-37
T1000-37 breakout box is our most versatile model, using dual 37 pin D-Sub connectors for signal capture or monitoring. Dual connectors provide a total of 74 test points plus a ground jack. All test points use standard size 4mm banana jacks. Test points may be connected using shorting banana cable to allow signal continuity. Ideal for continuity measurements, isolation testing, and signal capture.
-
product
NI-9425 , 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module
780176-01
24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module - The NI‑9425 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each digital input line is compatible with 24 V logic levels. The NI‑9425 offers isolation between the input and output banks from channel to earth ground. You cannot use the NI‑9425 in a CompactDAQ chassis to perform counter operations.
-
product
Millimeter Wave Products
Reliable Millimeter-Wave High-Power Products for Airborne, Maritime and Ground Mobile Deployment
-
product
SHC68-H1X38 High-Speed Digital Flying-Leads Cable Accessory, 1.5m
192681-1R5
76-Pin, Female Flying Leads to 68-Pin, Male VHDCI, Shielded, 50 Ω Digital Cable - The SHC68-H1X38 Digital Cable connects NI 6535/6/7, 654x, 655x, and 657x digital instruments directly to individual header pins for use with a custom breakout fixture. The flying-lead cable has paired signal and ground lines for each channel to preserve signal quality. Each signal and ground line is designed to plug directly into any 0.1 in. header connector. It is a shielded, 50 Ω cable.
-
product
PXI/PXIe Battery Simulator Module, 4-Channel, V/I Readback, 750 V Isolation
43-752A-012
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 4-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
Differential Probe
DP-16VF
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X400, X4000 Attenuator*To Ground MAX. Voltage: 3.5KV CAT III*Output Impedance 50Ω
-
product
NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module
780173-01
±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.
-
product
Digital And Analog Call Simulation
GL’s T1 E1/Analog Test Suite supports analysis and emulation of legacy protocols (MFCR2, E&M, SS1/SS4, SS5, Voice Call Signaling, 2-wire Call, SF Signaling (DTMF)) applicable to Federal Aviation Administration "FAA" within their National Airspace System "NAS" Ground-to-Ground Air Traffic Control Network and Voice System (NVS) to Analog Interphone.
-
product
AC Power Supply
FC5003
Behlman’s FC5003 is a ruggedly built, COTS frequency converter designed to convert 120/208 VAC, 3-phase, 60 Hz, ground power to 115/200 VAC, 3-phase, 400 Hz, aircraft power. The FC5003 is in a rugged 6U (10.5”H) 19 inch rack mount chassis with an input line cord with plug and an output receptacle.
-
product
Digital Ior Leakage Current Clamp Tester
MCL-400IR+
MULTI MEASURING INSTRUMENTS Co., Ltd.
・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).
-
product
Wristat Tester
WT 25-4145.26M
WT 25-4145.26M Wristat Tester is available to comply with D.O.D. 4145.26 specifications. The WT25-4145.26M Wristat Tester is designed to test the integrity of our WRISTAT in a fast, efficient, and simple manner. All the elements of the WRISTAT – continuity of the strap, integrity of the protective resistor, and satisfactory strap to skin contact – are easily confirmed by pressing the top cover of the WT25-4145.26M. The operator (wearer) is tested for a resistance to ground of greater than 250K ohms and less than1,200,000 ohms. The upper limit notifies you of an unacceptably high resistance value (IE possible loss of effective dissipation) and the lower limit warns of unsafe low resistance (possible risk of electric shock from surrounding motors, live wires etc.). The unit is not switchable.
-
product
32 Points Universal Terminal Base
HSL-TB32-U-DIN
*Field I/O wiring connection for HSL I/O modules*Spring terminal for easy field wiring*Power and ground included for each signal channel*Interlocking design for rugged installation*Power LED indicator
-
product
V-LISN
Measures the unsymmetric disturbance voltage between the two lines L1 and ground or L2 and ground respectively.
-
product
Multifunctional Safety Tests
Manufacturers of electrical or electronic products are required by law to carry out an electrical safety test before placing them on the market. This final test takes place at the end of the manufacturing process and is therefore also referred to as an EOL test (end-of-line). Depending on the prescribed standard and directive, the following parameters are tested:- Leakage current and discharge current- Insulation resistance or the insulation strenth- Dielectric strength or electric strength- Correct installation of the protective conductor (ground continuity and ground bond test)- Faultless functioning of the product under the conditions defined for intended use (function or run test
-
product
Air Baths/Oil Baths
Measurements International Ltd.
Peltier Cooled, DC Stirrer Motors for Low Electrical Noise, Dual Drain Ports, Adjustable Stir Speed, Free Standing Bench Height, Grounded Stainless Steel Tank.
-
product
DIELECTRIC and CONTINUITY TESTERS ( HI-POTS )
AV-25V-GC1-05
This tester is designed for testing equipment wiht a line cord which can be plugged directly to the tester. The continuity test is to determine whether the ground wire of the line-cord is well connected to the metal frame of the unit under test.
-
product
IF-Band
Quintech Electronics and Communications Inc.
A system or software used to set up and control an IF (Intermediate Frequency) switching matrix, which is a specialized piece of equipment primarily used in satellite ground stations and teleport facilities. Its main function is to automate the routing of signals.
-
product
Differential Probe
DP-16V
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-50MHz*Input Impedance 30MΩ// 1.5PF*x20, x200, x2000 Attenuator*To Ground MAX. Voltage: 8KV CAT III*Output Impedance 50Ω
-
product
Computer Safe Automotive Logic Probe
TE6-0718
Hangzhou Tonny Electric & Tools Co., Ltd.
*For use on 6V, 12V and 24V DC systems*Tests high and low voltages on all vehicle circuits, including computerized engine and body controls*Dual color LED indicates red for power and green for ground
-
product
PCI Bus Analog Output Board, 8 Isolated Outputs, 14 Bit
APCI-3501-8
*8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated
-
product
NI-9264, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
785190-02
25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The NI‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the NI‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection.
-
product
1/2 ATR COTS
ATR-A
Derived from successfully deployed ground mobile and fixed wing fast jet and UAV applications our aluminium ½ ATR to ARINC 404A is ideally suited to the exacting demands of Open VPX.
-
product
RF Power Transistors
Silicon Bipolar
Macom Technology Solutions Holdings Inc.
At MACOM we offer a broad range of silicon bipolar transistor products designed for applications ranging from DC to 3.5 GHz. Our silicon bipolar transistors are ideal for civil avionics, communications, networks, radar, and industrial, scientific, and medical applications. Our all-gold metallization fabrication processes ensure high performance and long term reliability for ground and space applications.
-
product
Digital I/O Board, 64 Optically Isolated I/O Channels, 24V
APCI-1564
32 bit, 33 MHz, PCI interfaceInput channels32 isolated digital input channels, 24 V, incl. 16 interruptible and 3 fast counter inputsInput channels organised in 4 groups of 8 channels, each group has its own ground lineVoltage reversal protectionAll inputs are filteredOutput channels32 isolated digital output channels, 10 to 36 VOutput current per channel 500 mAWatchdog for resetting the outputs to "0"After power/ON the outputs are reset to ì0îShort-circuit current for 16 outputs ~ 3 AShort-circuit current for 32 outputs ~ 6 AShort-circuit current per output ~1.5 AElectronic fuseOvertemperature and overvoltage protection24 V power outputs with protection diodes and filtersSpecial output capacitors minimise electromagnetic emissionsExternal 24 V supply screened through a protection circuitryShutdown logic when the external supply voltage drops unter 5 V
-
product
NI-9423, 24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module
779009-01
24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module - The NI‑9423 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels, can accept up to 30 V discrete logic levels, and has an LED that indicates the status. The NI‑9423 offers isolation between the input and output banks from channel to earth ground. The NI‑9423 is a correlated digital module, so it can perform correlated measurements, triggering, and sychronization when installed in a CompactDAQ chassis.
-
product
Ground Fault Locator
K-3837
Kongter Test & Measurement Co., Limited
Kongter’s K-3837 Ground Fault Locator is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems with earth fault. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. It is widely used in various DC systems including power utilities, locomotive, telecom and etc.
-
product
Motor Winding Ohmmeter
RMO-M Series
The motor/generator winding resistance test is used to identify open windings, shorts between two windings, short to grounds, connection mistakes or shorted turns. This non-invasive test of winding resistance helps to pinpoint problems regarding windings in stator or rotor part of an electrical machine. Additionally, motor winding ohmmeter has the capability of performing heat run test which will show a change in windings resistance with an increase of temperature.The RMO-M series is designed as an ideal aid in preventive maintenance of electrical motors and generators. They are powerful (up to 100A of test current), portable (8 kg) and generate DC current which is completely ripple-free. This makes measurement very precise with 0,1% accuracy.Three voltage channels make measurement very easy since it is possible to obtain a value of all three winding resistances in one measurement
-
product
Automated AC Digital Hipot Tester
Educated Design & Development, Inc.
1 button testing - No setup required, just plug right in! Or, make a plug for your cordless product, and plug right in! EASY!Easy to identify PASS / FAIL visible and audible indicationAuto Test Time (1 sec. / 60 sec.)+ - No need to set a timer or clock watchSafety Protected Start Switch -- Protects user from shock!Performs the Low Current Ground Continuity test at the same timeMeets UL, CSA, CE, EN, IEC, MIL and all other international safety agency requirements as well as UL 120Kohm requirementsIncludes ISO/IEC 17025 Accredited Calibration Certificate, accredited by ACLASS (Internationally accepted results... equivalent to A2LA)





























