Scattering
a propagating wave or moving particle's linear trajectory, interrupted by non-uniformity in the medium they move through.
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
product
Air Particulate Counter
CHY002
Using import semiconductor laser tube and import semiconductor photosensitive tube, assure sensitivity and response speed.Using import micropump,assure sampling volume steady,reduce noise.The key component-light scattering sensor obviously eliminate intracorporal stray light, improve SNR, test result more precise and reliable.The light scattering sensor got Chinese patent.Confidence measurement of this instrument,According to GB/T6167-2007 Standard,realize auto estimate clean class, creatively to auto estimate ≤9 location points clean class.1000 records stored, free to check previous data.User can optional PC data analysis software, realize data management.User can choose humidity sensor (optional accessories).Sampling volume display as digit, more intuitive and precise.“Measurement Number”function,realize multipoint management.Lithium battery,more safety,continuous working 6 hours.
-
product
Multi-Angle Light Scattering Detector
PN3621
Since the 1990s Postnova has been a leading innovator and developer of special advanced online Light Scattering solutions for coupling with chromatographic separation systems. The first model was the PD2000 - Static Light Scattering detector for coupling with Asymmetric Flow FFF. Later on the models PN3020 SLS and PN3070 MALS have been launched. Based on these over two decades of practical experience, Postnova has collected a unique competence in the area of Laser Light Scattering and has developed the unique PN3621 MALS - Multi-Angle Light Scattering detector series. The model PN3621 MALS is a completely new type of high performance MALS detector system with a unique range of specifications.
-
product
Vector Network Analyzer
SNA5000A
The SIGLENT SNA5000A series of Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz, with 2 and 4 port models available. Designed to give you instant insight into scattering, differential, and time-domain measurements. They are effective instrumentation for determining the Q-factor, bandwidth, and insertion loss filters and feature impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation, and adapter removal/insertion adjustments. There are five sweep types: Linear-Frequency, Log-Frequency, Power-Sweep, CW-Time, and Segment-Sweep mode. The SNA5000A series VNAs also support scattering-parameter correction of SOLT, SOLR, TRL, Response, and Enhanced Response for increased flexibility in R&D and manufacturing applications.
-
product
Multi-Angle Light Scattering Detectors
Since the 1990s Postnova has been a leading innovator and developer of special advanced online Light Scattering solutions for coupling with chromatographic separation systems. The first model was the PD2000 - Static Light Scattering detector for coupling with Asymmetric Flow FFF. Later on the models PN3020 SLS and PN3070 MALS have been launched. Based on these over two decades of practical experience, Postnova has collected a unique competence in the area of Laser Light Scattering and has developed the unique PN3621 MALS - Multi-Angle Light Scattering detector series. The model PN3621 MALS is a completely new type of high performance MALS detector system with a unique range of specifications.
-
product
FT-NIR for Process Analytics
QuasIR™ 2000E
Galaxy Scientific’s QuasIR™ 2000E is designed for continuous measurement of the chemical composition of material transported on a conveyor belt, through a pipe, or in a chute. Our unique external projection optics use high powered tungsten lamps to illuminate the sample from as far as 24 inches away and collect the scattered reflection off the sample through a fiber optic cable. The analysis spot size can be set as small as 0.5″ or as large as 8″ in diameter and can be custom tailored to applications needs.
-
product
Scattered Light Dust Measuring Devices
The reliable way to detect low dust concentrationsLight scattering by dust particles is a measurement principle that allows even very low concentrations of dust to be detected. Depending on the system-specific requirements, either forward scattering or backward scattering can be used in this context. Both measurement principles return stable and reproducible measurement results, regardless of the gas velocity, humidity, or dust particle charges.
-
product
Turbidity Sensor
TF56-N
The TF56-N sensor is an inline real-time device designed to measure light absorbance at 11° caused by interaction with process turbidity. As an NIR light beam is passed through a dynamic process stream, the sensor simultaneously measures the amount of light scattered at 11° and the remaining amount of un-scattered light at 0°.
-
product
Gloss & Reflectance
Visual appearance can determine a person’s perception of a product. Colour and Gloss are two key parameters that are used to define a product’s overall quality. Perception is subjective, but Elcometer’s range of gloss meters, DOI meters and colour assessment equipment can quantify appearance measurement. The ability of a surface to reflect light without scattering is known as gloss. Using a gloss meter, gloss is measured by directing a constant intensity light beam at a fixed angle to the test surface and then by monitoring the amount of reflected light at the same angle. Different surfaces require different reflective angles.
-
product
Vector Network Analyzer
SIGLENT Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz, with 2/4-port models that can quickly deliver reliable scattering, differential, and time-domain parameter measurements.
-
product
High-efficiency Fiber Stretcher
PZ2
The PZ2 provides the most extensive stretch of our stretcher product family. It is a fiber wound piezoelectric element for use in a wide range of optical interferometric measurement and sensing system applications. Typical uses include open loop demodulation, sensor simulation, white-light scanning interferometry and large angle modulation of interferometric phase. The PZ2 is ideal for use in OCT [Optical Coherence Tomography] and OCDR [Optical Coherence Domain Reflectometry] applications requiring scattering or boundary definition measurements.
-
product
Integrated Modular Electromagnetic Modeling Suite
EM.Cube
EM.Cube® is an industry-recognized simulation suite for electromagnetic modeling of RF system engineering problems. It features several distinct simulation engines that can solve a wide range of modeling problems such as electromagnetic radiation, scattering, wave propagation in various media, coupling, interference, signal integrity, field interactions with biological systems, etc. Using EM.Cube, you can solve problems of different sizes and length scales, varying from a few microns in MEMS devices to several miles in large urban propagation scenes.
-
product
Fiber Fusion Splicer
Shenzhen Sharingtek Communication Co., LTD
Fusion splicing is the act of joining two optical fibers end-to-end. The goal is to fuse the two fibers together in such a way that light passing through the fibers is not scattered or reflected back by the splice, and so that the splice and the region surrounding it are almost as strong as the intact fiber.
-
product
Hybrid Raman/Er-doped Fiber Amplifier
HFA5000
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600nm.
-
product
PCI Card with 8 output channels
PCI_LVDS_8T
The PCI-LVDS-8T PCI card has 8 channels of LVDS output (8T), digital filtering and storage. The PCI-LVDS-8T is compatible with TIA/EIA-644 LVDS standards. The card features "Scatter gather" DMA data transfer into the transmit memories.
-
product
Multi-angle Polarized Light Scattering Measurements
LISST-VSF
In-situ measurements of P11, P12 and P22 elements of scattering Mueller matrix, (P11 is VSF) from 15-150º.VSF (P11) only at small angles, 0.05 to 10º in 32 logarithmic steps in angles.Only two detectors employed with absolute radiant sensitivity (A/W) calibration.Beam attenuation measured with optics similar to our LISST-100X.Roving Eyeball™ optics permit 1-degree resolution in angles between 15 -150º.Sampling rate at 3 seconds per measurement set (involves 3 turns of Roving Eyeball with unpolarized, vertical, and horizontal polarized laser).Daylight rejection by laser modulation.Dynamic range in VSF measurements extended via laser power modulation.Data from small and large angles in a single data stream, including depth and temperature.
-
product
Raman Probes
As with Raman spectrometers, a Raman probe is used to measure the inelastic scattering of light from a sample. Raman scattering is produced when the energy levels of photons are shifted up or down as a result of excitation by a monochromatic source (usually a laser). The change in vibrational frequency is used to determine the composition of a target substance.
-
product
UltraScan VIS Spectrophotometer
Hunter Associates Laboratory, Inc.
The UltraScan VIS easily measures both reflected and transmitted color as well as transmission haze and meets CIE, ASTM and USP guidelines for accurate color measurement. UltraScan VIS uses diffuse/8° geometry with automated specular component inclusion/exclusion. For transmission measurement, the use of a robust CIE-conforming sphere instrument (TTRAN Total Transmission mode) effectively negates the effects of minor scattering typically found in transparent samples.
-
product
Particle & Molecular Size/Charge Analyzers
Zetasizer Range
Instruments in the Zetasizer range are used to measure particle and molecular size from less than a nanometer to several microns using dynamic light scattering; zeta potential and electrophoretic mobility using electrophoretic light scattering; and molecular weight using static light scattering. The Zetasizer system is available in a range of variants, including the new Zetasizer Pro and Ultra. These two new systems offer unprecedented ease-of-use and flexibility, along with empowering user guidance and novel measurement techniques such as MADLS® and Particle Concentration.
-
product
Surface Analysis
Innova-IRIS
This provides researchers a perfect combination of chemical or crystallographic information at high spatial and spectral resolution with the most advanced atomic force microscopy characterization. The Innova-IRIS can be integrated with your choice of a leading Raman system to provide the best opaque sample TERS investigations available today. However you tailor your system, your application will benefit from Bruker exclusive, high-contrast IRIS TERS probes and the best tip preservation and lowest drift, guaranteeing that alignment is preserved even over the optical integration times necessary to interrogate weak Raman scatterers.
-
product
Omnisens Optical Fiber And Cable Measurement And Quality Control
https://www.omnisens.com/uploads/1/2/0/5/120592129/telecom-1_orig.png
To provide quality control or help with the design and testing of fibers, Omnisens Vision offers fast, accurate strain and temperature measurements.Omnisens Vision is based on Brillouin scattering. In single mode fibers it produces precision readings with high spatial resolution over long distances and/or large loss test conditions. It is capable of high speed testing in dynamic situations such as flex fatigue.Its configuration flexibility makes the Omnisens Vision well adapted to a wide variety of test & measurement needs.
-
product
VIS/NIR Sensor
AF26
The AF26 is a high precision dual channel color sensor for inline operation; the secondary wavelength is designed to compensate the desired light absorbance measurement from any undesired light scattering influence, such as suspended solids, gas bubbles, immiscible fluids or window fouling. The AF26 sensor’s output can be correlated to almost any color scale including APHA and Hazen.
-
product
TSS Meter
LD-LTSS-A10
TSS meterLD-LTSS-A10is a tabletop meter with a dual-beam infrared scattered light photometerdetection system for enhanced stability. Built-in self-diagnosis function to ensure dataaccuracy. Optional cleaning brush for automate cleansing function to reduce the sensormaintenance.
-
product
kSA SpectR
The kSA SpectR is a complete metrology solution for measurement of absolute spectral reflectance, growth rate and end point detection. Custom spectral features such as reflectance minima, maxima, inflection points, or baseline scatter level, over a user defined wavelength range of interest, are easily measured.
-
product
Molecular Weight Analyzers
Brookhaven Instruments Corporation
Molecular weight and size are two key properties of all macromolecules including biologically important and synthetic polymers. Performance and processability are directly related to these parameters. Light scattering is capable of absolute measurements in either batch or flow mode. For distribution information, couple a GPC/SEC instrument to a light scattering detector.
-
product
MultiBeam System
FIB
An easy-to-use, out-lens type scanning electron microscope (SEM) equipped with a Schottky electron gun, as well as a new FIB column capable of large current processing (maximum ion current 90nA) installed into one chamber. JIB-4610F enables high-resolution SEM observation after high-speed cross-section milling with FIB, and high-speed analysis with a variety of analytical instruments, such as energy dispersive X-ray spectroscopy (EDS) that takes advantage of the Schottky electron gun delivering a large probe current (200nA), electron back scatter diffraction (EBSD) to perform crystallographic characterization, and cathodoluminescence (CLD). In addition, the 3D analysis function Cut & See is included in the standard configuration, allowing cross-section milling to be executed automatically at fixed intervals, while acquiring SEM images for each cross section.
-
product
C-Band Separate Raman Fiber Amplifier
RFA5000
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to the multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600 nm.
-
product
Laser Turbidity Meter
HU-200TB-EH
HU-200TB-EH is a laser-type turbidity meter that can measure turbidity of membrane filtered water, etc. with a resolution of 0.0001 degrees. A high-sensitivity turbidty meter with a minimum resolution of 0.0001 degrees at a measurement range of 0.0000 to 2.0000 degrees, which uses a long-lasting semiconductor laser as the light source and employs a transmission 90-degree scattering light method.This is best suited for sensitive measurement of turbidity on surface water.
-
product
Nephelometric Turbidity Sensor
DTF16
The DTF16 is a high 3 channel turbidity sensor for installation into pipelines, measuring turbidity at two angles of scattered light and a direct reference channel in various liquid flow streams.
-
product
L-Band Separate Raman Fiber Amplifier
RFA6000
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to the multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600 nm.