Immunity
See Also: Immunity Test, Radiated Immunity, EMC
-
product
Electromagnetic Immunity Scanner
SmartScan BASIC
The BASIC is manually operated system for performing susceptibility scanning at the system level with minimal data storage capability. This system includes:1. Up to 8kV (optional. 4kV base) pulse generator for ESD susceptibility testing- Camera and camera shutter to take DUT picture and failing spots- Control computer2. Up to 8kV Probe Sets:- 1mm Hx/y Field Probe- 5mm Hx/y Field Probe- D=8mm Hz Field Probe- D=8mm Ez Field Probe- Contact API for custom design probes3. Manual input of testing location and failing condition over the DUT to be included in final report.
-
product
Immunity Development System
Used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes of burst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness of the measures taken.
-
product
Transient Immunity Tester
KES7700
Transient Immunity Tester KES7700 Series are transient surge tester that utilizes a compact unit system. A surge generator circuit is installed for each pulse unit as the tester meets the requirement of ISO7637-2, ISO7637-3, ISO16750-2, JASO D001, SAEJ1113, and other standards. The KES7700 Series meets a broad range of independent automobile manufacturer standards as well.
-
product
EMI EMC test Solutions for Immunity
Scientific Mes-Technik Private Ltd
EMI EMC test Solutions for Immunity
-
product
Damped Oscillatory Magnetic Field Immunity Tester
DOMF61000-10
DOMF61000-10 damped oscillatory magnetic field immunity test system included damped oscillating wave generator and single ring coil, it’s designed for to do damping oscillation magnetic field immunity test and fully meet IEC 61000-4-10, EN61000-4-10 and GB/T 17626.10 standards requirement.
-
product
Immunity Testing Systems
CIS Series
The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes an ACS series power amplifier, coupling/decoupling Network (CDN), directional coupler, 150Ω to 50Ω adapters, power attenuators, cables and [optional] CSAT software. These systems, when properly configured, are capable of testing your products to all levels given in IEC 61000-4-6 up to 230 MHz. You can choose from three systems. Follow the links below for detailed information, including a comprehensive datasheet listing system specs.
-
product
Radiated Immunity Test System
Beijing KeHuan Century EMC Technology Co,.LTD
Radiation Immunity Test System.
-
product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
product
ESD Protection
Protection against electrostatic discharges (ESD) is part of EMC Immunity (Electro Magnetic Compatibility) requirements. It is the ability for equipment to properly operate in its electromagnetic environment by limiting the reception of electromagnetic energy that may cause physical damage. ESD can be either conducted under the form of a transient voltage or can be radiated due to its fast rising time: powerful harmonics will generate erratic behavior by the application by coupling with other signals. Printed circuit boards must be protected against the effects of electrostatic discharge.
-
product
EMC Testing Services
Our sophisticated technology can meet the diversified needs of customers. Component Tests: Immunity, Radiated Immunity, ALSE, TEM cell, Bulk Current Injection, Stripline, Conducted Immunity, Transient Immunity, Power Supply Variations, Electrostatic Discharge Emissions, Radiated Emissions, Conducted Emissions, Transient Emissions. Vehicle Tests - Radiated Immunity, Radiated Emissions.
-
product
Immunity
RF coupling
is used for the conducted measurement of the immunity according to IEC 62132-4.
-
product
Turned Multiple Dipole Antenna
MODP2080
Antenna for Radiation Immunity Test on Car Max. Input Power : 12kW & High Erectric Field at = 4 : 100V/m Contolable the Height/Deviation by own unique Stand Patent Information.
-
product
Power Amplifiers
RF Range
The RF power amplifier range from Laplace is specifically designed for EMC Immunity testing. These are compact units with characteristics matched to the requirements of IEC standards.
-
product
Conducted Immunity Test System
Conducted RF immunity tests acc. to IEC/EN61000-4-6 and BCI tests acc. to ISO 11452-4 and MIL-STD 461 CS 114 Signal generator,RF-power amplifier, RF-power meter and directional coupler (optional) in one 19”-caseStand-alone operation possible with optional available netbookControl-software includedMost important parameters are shown on an integrated displayAutomatic EUT-monitoringOperation via USB port of a PC or NotebookComplete range of CDNs available
-
product
14W to 60W - Single Output
ZPSA Series
*Wide Range AC Input*Low Profile, Industry Standard Footprint*Global Safety Agency Compliance*EN61000-4 Immunity
-
product
10W to 60W - Single Output / Multiple Output
PXD Series
*Industry Standard 2" x 1" Footprint*9-18, 9-36, 18-36, 18-75, 36-75 Vdc Inputs*3.3, 5, 12, 15, 24, 48, ±5, ±12, ±15, ±24 Vdc Outputs*1600 Vdc Isolation*-40 to 105 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
product
Pre-Scan Emissions/Immunity Chambers
3m pre-scan Immunity/Emissions semi-anechoic chambers are designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 compliant radiated immunity and emissions measurements. When using this chamber for ANSI C63.4 pre-compliant radiated emissions pre-scan measurements there’s a limited scan height.
-
product
CDN - Coupling / Decoupling Networks
The Coupling- / Decoupling Networks are used to inject common mode disturbances to Equipment under Test (EuT). Further the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.
-
product
Anechoic Chamber
EMC-3
A 3 meter test range ensuring fully compliant Emission and Immunity testing. Ferrite and hybrid pyramidal absorbers are combined in a unique pattern within a SmartShield high performance chamber. Operating at a 3m test distance, this chamber is compliant to CISPR-16 with a measurement zone diameter of 1-2 meters.
-
product
Immunity DC
PGA 1240
The power generator PGA 1240 is suitable for EMC testing in accordance with standard IEC / EN 61000-4-16 in the frequency range from DC to 300 kHz.
-
product
TDK Software
TDK Software - Testlab, Emissions Lab, Cundicted Immunity Lab, Radiated Immunity Lab, EUT Monitoring Lab, GTEM Emissions Lab
-
product
Ultra-Compact Immunity Tester
AXOS5
The AXOS5 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS5 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
product
Ultra-Compact Immunity Tester
AXOS8
The AXOS8 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS8 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
product
EFT Immunity Measurement
EFT61000-4
EFT immunity tester EFT61000-4 is specially designed according to the characteristics and requirements of EFT measurement and it is an ideal disturbance source of EMS measurement. They have fine performance, such as high stability, high reliability, easy to use etc. It meets the standard requirements of IEC 61000-4-4, EN 61000-4-4, GB/T17215.301, GB/T17215.322 and GB/T17626.4. EFT61000-4 has LCD display in both English and Chinese.
-
product
Dipole Antennas
Provides reliable, repeatable measurements. Suitable of FCC, MIL-STD, VDE, Tempest and Immunity stesting.
-
product
Multifunctional Immunity Test System For Automotive Electronics
EMS-ISO7637
EMS-ISO7637 automotive multifunctional immunity test system meet newest ISO7637-2 requirement of
. This standard was issued by international organization for standardization, and this system included all of ISO-7637 required test waveform and meet most of automotive manufacturer’s requirement for automotive electronic immunity test. -
product
EMC Measurements
Immunity and emission measurements Kiwa Dare is an accredited test house that performs full compliant EMC measurements in the field of EMC legislation. All results are recorded and represented in reports which form the foundation on which clients can put the CE mark on their product. Besides that our tests are performed under accreditation for Automotive, medical, maritime, aerospace military and railway applications.
-
product
RF Conducted Immunity Test System
RFCI61000-4-6
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.
-
product
40W to 60W - Single Output / Multiple Output
PXF Series
*Industry Standard 2" x 2" Footprint*9-18, 9-36, 18-36, 18-75 Vdc Inputs*Single, Dual and Triple Outputs*1600 Vdc Isolation*-40 to 100 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
product
EOS Tester
KT-200SG
This test instrument stands for the EMI(Electro Magnetic Immunity) ability test to the electric devices, electronic circuit boards & electric equipments. Recently this instrument is widly used in many companies in Korea & other countries to test the immunity to thier products-power supply, drive PCBs, communication systems, LCD display panels whether they are safe or not against the impulse & noise.All for the purpose, of this object, it generates 4 ~ 5 kinds of different impulse test waveforms.Output test voltage level : 5 ~ 200 V ImpulseOutput voltage polarity : Positive, NegativeType of waveforms





























