Transformer Oil
See Also: Oil Dielectric Test Set
-
Product
Control Transformers
-
ENTES control transformers ensure the safe operation of measuring devices with 24 VAC supply voltage for electical control panels. Input voltages of Control transformers are either fixed (230 or 400V) or selectable with taps (400;230+15-15).
-
Product
8-Gas On-Line Transformer Gas Analyser
TRANSFIX
-
The TRANSFIX is an 8-gas on-line transformer DGA monitoring unit. Using specially developed advanced photo-acoustic detection technology, the TRANSFIX measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect and diagnose a complete range of transformer faults.
-
Product
Test Set For Instrument Transformer
-
This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.
-
Product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
-
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
Oil Pour Point Tester
-
Weshine Electric Manufacturing Co., Ltd
WESHINE’s fully-integrated, automatic cloud and pour point apparatus(VS-9612 Cloud and Pour Point Tester) offers precise and convenient flow testing of petroleum products, biodiesel fuels, additives and lubricating oils.
-
Product
Current Transformers
-
Supreme Instrument Laboratories
Portable Low Tension precision grade multi ratio Current Transformers, housed in laminated wooden cabinet, wound primary with suitable terminals on highly insulated bakelite panel upto 100 Amps. For higher ranges, a centre hole is provided for passing primary conductors for desired range.
-
Product
Transformer Turns Ratio Tester
CXBC-901
-
Shenzhen Chuangxin Instruments Co., Ltd.
Transformer Turns Ration Tester is applied to measure the voltage ratio and group testing of the three or single phase transformer. All the test results could be printed by the micro printer or saved in the tester.
-
Product
Transformer Turn Ratio Tester
KVBB-II
-
KV Hipot Power Test Equipment Co.,Ltd
KVBB-II Transformer turn ratio tester is used to check turn ratio of transformer, tap switch situation, whether transformer interturn is short circuit and transformer can run in parallel or not.
-
Product
Power Transformer
-
Transformer turn ratio meter is special designed for power transformer (single phase & three phases) and instrument transformer testing, suitable for testing in substation, transformer manufacturer, meter manufacturer. It helps to detect faulty transformer winding and tap changer position. It’s fully automatic device, can recognizes winding connection and vector group number of transformer winding. The user only need connect measuring cable and press start button and come out the test result.
-
Product
Current Transformers
Sensors
-
The Current Transformer (CT) is the sensor which measures the amount of current draw from the wire it is installed on.
-
Product
Telecom Transformers
-
Our high-performance telecom transformers support multiple home phone line and power line network applications. These transformers have excellent THD performance, small footprints, and are designed to exceed industry standards. Single, dual, quad, six, octal and twelve transformer numbers are available.
-
Product
Oil Tan Delta Test Set
-
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.
-
Product
L.V. Current Transformers
-
ENTES LV Current Transformers are measuring transformers which transform the primary current by a specified ratio to its secondary side with a phase difference of 0 degrees. They provide isolation of the relays and measuring devices from the HV side of the network.
-
Product
TRANSFORMER WINDING RESISTANCE METER
-
International Biological Laboratories
This Test set is suitable to measure winding resistance of transformers, single or 3-phase, star or delta connected upto several MVA.Two independent displays read the resistance of both primary & secondary windings simultaneously. However, primary or secondary winding can also be measured separately.
-
Product
Automatic Transmission Oil Pressure Tester
ATG5AK
-
Checks oil pressure in automatic transmissions and gasoline engines on most domestic and import cars and light trucks. Includes 6' of oil proof nitrile hose to make testing easier as well as standard and metric fittings. 2-1/2" gauge has a dual scale dial with ranges from 0-100psi and 0-7 bar. 3-1/2" gauge has a dual scale dial with ranges from 0-400psi and 0-28 kg/cm2.
-
Product
Transformer Test Equipment
-
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
Product
Current Transformer
ST-3RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 20~300
-
Product
Transformer Winding Resistance Meters
-
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
Product
High Voltage Transformer
-
RR manufactures HIGH VOLTAGE TRANSFORMERS for various Industrial Applications.
-
Product
High Frequency Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Current Transformer
CT
-
The split-core current transformers are easily installed with the snap on design.
-
Product
Standard Resistor Oil Bath
9400
-
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
Product
Phase Shifting Transformer
-
Supreme Instrument Laboratories
Supreme make PHASE SHIFTING TRANSFORMERS are special transformers which provide convenient means to adjust phase angle (power factor) of A.C. loading circuit while testing power factor sensitive device for the full 90 degree LAG through '0' degree to 90 degree LEAD. Based on their rating these Phase shifters are manufactured in two configuration.
-
Product
Automatic Oil Insulation Test Kit
-
The test kit is fully automatic and has the facility forAuto/Manual selections. The operator simply needs thesample in the test vessel & selects the required test. Testingcan be done as per many international ( IEC & Europeanstandards ) which are programmed into the instrumentmemory . Stand time, Stir times & Rate of rise of appliedvoltage can be selected in Custom Mode also , one setof such selected mode can also be stored in the memory. In addition to the above set can also perform withstand test(proof) tests. In this test the set allows the set voltage to pre-set value & hold for one minute to see if breakdown occurs. The backlit LCD is used for user friendly operationsduring the test process. It also display fault condition messages such as open ground and cover open . All the user selected programmes are chosen through(4x3) key pad.The test results can be printed along with with test type, date, time, breakdown test voltage, averages and deviations. Voltage value can be measured & printed with a resolution of 0.1kV. In reprint option it is possible to have number of printouts for the last test. For each test the readings are recorded and stored in memory.
-
Product
20 Amp Current Transformer Burden Test Set
1044A
-
Due to overwhelming demand, TESCO is pleased to re-introduce the 1044A 20 Amp Current Transformer Burden Test Set. This light weight, hand held unit is a simple and inexpensive means whereby a current transformer installation may be quickly checked for many sources of trouble. The 1044A provides utilities a less expensive and more traditional option for checking larger services for potential meter circuit related issues.
-
Product
AC/DC Clamp-On Current Transformers
-
AC/DC Clamp-On Current Transformers by AYA Instruments
-
Product
Power Transformer Automatic Test Device
XD71
-
Hangzhou Xihu Electronic Institute
The device is used for power transformer power outage routine test items to do automated testing.Which is characterized by dielectric loss, insulation resistance, DC resistance, tap-changer switching characteristics, short circuit impedance and variable ratio of six test items are concentrated in an instrument,so that the instrument function, test power and test lead height fusion.Field test, just start wiring once, at the end of unplugging wiring once,the middle process by the test personnel in the computer terminal to send command control,the test system automatically completes all or part of the above test items.
-
Product
X-ray Fluorescence Sulfur-in-Oil Analyzer
SLFA-60
-
HORIBA introduces the new standard of transportable sulfur-in-oil analyzers, the SLFA-60. This instrument introduces new software and hardware features to meet the growing changes in the petroleum industry. The instrument has expanded storage of calibration curves and data can be exported using USB output. The measurement range has increased to 0-9.9999 wt% to cover high sulfur crudes and shale oil markets.
-
Product
Current Transformer
ST-100CT
-
Standard Electric Works Co., Ltd
● 1000/5A - 3000/5A● 10-15V A● Class 1● Insulation 600V