Product
Single Shot Third-order Cross- Correlator
Rincon SS
-
Specifically developed for measuring a wide array of output parameters from ultrafast laser systems including: contrast ratio of laser pulses, determining pulse pedestal, pre- and post-pulses, and amplified spontaneous emission in femtosecond systems.
-
Product
Cross-Correlator Pulse Profiling Systems
Rincon
-
The third order cross-correlator is ideal for looking at the full range of output from amplified femtosecond laser systems. High temporal resolution over a long (close to 1 ns) window shows pulse features that are usually missed, giving the user a detailed and complete picture of the quality and stability of the output pulse parameters of their femtosecond lasersystem.
-
Product
Rapid Scanning Auto-Correlator / Cross-Correlator
FR-103XL
-
The FR-103XL is a dispersion-free Autocorrelator/CrossCorrelator for monitoring the temporal width of ultrashort optical pulses. Offering unsurpassed sensitivity and resolution, it is compact and easy to operate. The FR-103XL is ideally suited for the measurement weak signals in optical telecommunications, as well as pulses from other mode-locked lasers such as Ti-Sapphire.
-
Product
Phase Noise Analyzer
NXA-50
-
This new NXA-50 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 50 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
Product
Phase Noise Analyzers
-
The phase noise analyzer portfolio from Rohde & Schwarz offers an affordable, mid-range solution with high sensitivity and fast measurements as well as high-end ultra-high-sensitivity solutions with advanced measurements modes. Ideal for phase noise analysis and VCO tests, the industry-leading solutions enable two-path phase noise analysis with real-time cross correlation and fast VCO characterization with built-in low-noise DC sources. Additionally, high-end signal and spectrum analysis can be added into a single box.
-
Product
Phase Noise Analyzer
NXA-6
-
This new NXA-6 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 6 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
Product
Auto-Correlator/Cross-Correlator
FR-103WS
-
The FR-103WS is a dispersion-free Autocorrelator/Crosscorrelator for monitoring the temporal width of ultrashort optical pulses. While providing excellent sensitivity and resolution, the FR-103WS is ideally suited for the measurement of long pulsewidths (up to 200ps).
-
Product
Phase Noise Analyzer
NXA-26
-
This new NXA-26 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 26.5 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range. The NXA-26 combines over 25 years of Phase Noise Measurement Technology with an easy to navigate user interface. System operation requires minimal training that will have you making measurements in minutes.
-
Product
Cross Browser Testing
-
Automate your tests on more than 800 instantly available browser / OS combinations (even beta versions) without the time, expense or hassle of managing infrastructure.
-
Product
Cross Browser Testing
BrowseEmAll
-
Live Testing, Screenshots, Code Analytics & Selenium Integration On Your Local Machine. Every browser is just one click away. Mobile Simulators. Test for iOS, Blackberry, Windows Phone and Android. Screenshots. Find layout issues with screenshots. Automated Compatibility. See problems directly in your Code. Side by Side Test browsers and mobile devices simultaneously. Test Automation. Run Selenium Tests Out Of The Box.
-
Product
Cross Cut Adhesion Tester
1540
-
The Elcometer 1540 Cross Cut Adhesion Tester is a simple instrument for quickly determining the coating adhesion of a large variety of paints up to 50µm (2 mils) thickness.
-
Product
Cross Voltage Testers
-
designed to perform the 60 Hz power line cross test/AC power fault tests required in GR 1089 issue 6 table 4.5 surge test 3,4, 4.3,and 6, and for UL 1950 section 6.4 paragraph 3 and 4.. Preset and Adjustable Time Settings Measuring Terminals including Voltage Sense and Current Shunt portals provide a safe location for users to accurately measure test voltages and output current while setting up tests. Calibration of the Mini_PT-600 is designed to be performed with a simple handheld multi-meter and the removable Currents Shunts can be easily sent to a calibration laboratory if required.
-
Product
Gas Filter Correlation CO Analyzer
Model N300
-
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Correlative Microscopy
-
Our modular software platforms enable you to acquire, process and analyze images in multiple dimensions and over various timepoints
-
Product
Video Cross Line Generator
CL5410
-
The CL5410 can generate up to 4 lines at once and each line may be on a horizontal or vertical axis. This allows the CL5410 to replace the CL5400C, CL5404C and CL5405C and retain all of the functionality of each unit and more. The CL5410 is built on a new platform and allows a wide variety of options to be selected in the menu system. However, even with the enhanced menus, the CL5410 still has the same legendary ease of use like our previous models. That means enough buttons to change commonly used setting easily without the hassle of a menu..
-
Product
Gas Filter Correlation CO Analyzer
Model T300U
-
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
Product
Crossed Roller Rail Sets
-
Del-Tron’s crossed roller rail sets (or crossed roller bearings) are compact, precision rail sets that can support and guide high loads with high accuracy, excellent repeatability, and low friction. A complete range of profiles are offered with roller diameters ranging from 1.5mm up to 6 millimeters, providing load carrying capacities to 2800 lbs. For vertical applications or applications involving high acceleration or deceleration forces you may want to consider our Anti-Creep crossed roller rail sets.
-
Product
Collaborative Correlative Microscopy
nanoGPS navYX
-
Correlative microscopy is the combination of multiple modalities performed on the same sample. The results produced emphasize the strengths of each modality while offsetting their individual limitations.nanoGPS navYX™ is an open solution which makes SEM-Raman correlative microscopy seamless regardless of the electron and optical microscopes used. Simply stick the Coordinates Transfer System to the sample!
-
Product
Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer
Model T360M
-
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Real-time and Direct Correlative Nanoscopy
LabRAM Soleil Nano
-
Fully integrated system based on our OmegaScope scanning probe microscope and LabRAM Soleil Raman microscope. LabRAM Soleil Nano offers unprecedented capabilities for direct co-localized AFM-Raman and photoluminescence measurements. AFM imaging modes (topographic, electrical, mechanical, etc.) and Raman acquisition can be performed either sequentially or simultaneously at the same location of the sample surface. Optical nano-resolution is also achievable with Tip-Enhanced Raman Spectroscopy and Photoluminescence (TERS/ TEPL). LabRAM Soleil Nano is compatible with the environmental chamber for AFM and Raman measurements in controlled atmosphere and at low temperatures.
-
Product
Crossed Roller Tables(Aluminum & Steel)
-
Del-Tron’s crossed roller tables are known for their high accuracy and exceptional load carrying capabilities. Our crossed roller bearings are available in both aluminum and steel, and the perfect choice for applications where these criteria must be met. Accuracies range from 0.0001” per inch of travel straight line accuracy on our aluminum tables to 0.00008” of parallelism on our steel crossed roller tables and are capable of carrying loads in excess of 2600 lbs.
-
Product
ABex High Voltage Matrix Module with 12x4 Cross Points
ABex AM-305 HV-Matrix
Matrix Switch Module
The ABex AM-305 is a 12×4 channel high voltage switching matrix module for the Konrad ABex System. The matrix module is designed to switch voltages up to 1000 V with a current of up to 1 A.
-
Product
Gas Filter Correlation CO2 Analyzer
Model N360
-
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Cross Needle Meter. 1.8 - 60/144/440
MFJ-864
-
This new MFJ Cross Needle SWR/Wattmeter covers HF thru VHF 1.8 - 60MHz, 144 MHz and 440 Mhz bands. It features separate HF and VHF / UHF directional couplers, each with its own SO-239 connectors. This lets you connect your HF and VHF/UHF transceivers at the same time.
-
Product
Cross Flow Cell
-
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
Product
Digital Image Correlation (DIC) Measurement System
EduDIC
-
EduDIC is a complete Digital Image Correlation (DIC) measurement system, designed as a simple and convenient educational training tool for academic courses in experimental solid mechanics. This easy-to-use system allows academic instructors to effectively present the optical measurement technique of DIC for materials testing to the engineers and scientists of tomorrow.
-
Product
High-Speed Digital Image Correlation System
Q-450
-
The 3D High-Speed Image Correlation System Q-450 allows the full-field, non-contact and three-dimensional dynamic measurement of shape, displacements and strains on components and structures made from almost any material. Based on the digital image correlation technique, the Q-450 system is designed for full-field vibration analysis and high speed transient events. This makes it ideal for ballistics testing, fracture mechanics, shock excitations, the Hopkinson Bar test, or Impact Testing.
-
Product
Mid-Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300M
-
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance from low to high range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
-
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.