product
Digital Broadcast Plug-In Elements
92000
The 92000 series of Coaxial Dynamics Digital Broadcast Elements are calibrated to exacting specifications to assure interchangeability with one another and may be used in any of our Digital Broadcast Wattmeters with appropriate size line section
-
product
MEMS Test System Development
olidus Technologies’ can design and build a test system customized for your exact needs, using our own or off the shelf components:Custom MEMS Test Systems. We can integrate and assemble test equipment and handling systems to fit your requirements. Custom MEMS Test Software. We can write custom software for device-specific calibration and testing, interfacing various instruments and handling systems, or create a customized GUI. We can also adapt our standard STI Test Software to work on your hardware system.
-
product
ESU Analyzer
ESU-2050
The BC Biomedical ESU-2050 ESU Analyzer is the first instrument of its kind on the market. Designed through extensive collaboration with several of the world's leading electrosurgery generator manufacturers. It is the only ESU Analyzer on today's market with a 1% reading level of accuracy. Calibration quality analyzer; uses external precision non-inductive test loads and wide band current transformer.
-
product
Instrument Transformer Calibrators
CTPT 81
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
product
Proprietary Software
WinFT
WinFT is our proprietary software which makes D&P instruments so functional and easy to winft1_largeuse. Based on the Windows operating system, this software provides simple and intuitive control of the instrument. All of the usual File functions are available, as well as controls over instrument settings such as resolution, apodization, zero-fill and number of coadds. Display options enable the user to display interferograms, spectra or both, as well as to adjust plot scales and units. Onboard math processing allows for real-time calculation of ratio, difference, and absorbance, and when using our calibrated hot-cold blackbody calibrators, the ability to measure calibrated radiance. Further, WinFT offers the ability to measure sample temperature in the radiance function by matching a Planck to the calibrated radiance. With the gold diffuse plate, the software can also compute and display absolute emissivity of samples. Our software also enables exporting of data files, now made even easier with our USB and LAN connections. In addition, the software has been designed to be easily run using the keyboard function keys and single letter commands, making the use of a mouse in the field optionalas well as minimizing key strokes when taking measurements in the field.
-
product
Automated Pressure Calibration System
4322
The Fluke Calibration 4322 Automated Pressure Calibration System enables almost any user to calibrate almost any pressure gauge, transducer, transmitter or switch, including vacuum, compound, absolute and high-pressure devices. It provides high-end, laboratory-grade performance across a very wide range, on the bench or in situ.
-
product
Signal Conditioner
DMA2
Din rail mountable with user selectable outputs of +/-10V, +/-5V or 4-20 mA. 10-28VDC powered suitable for battery or automotive use. Features 1000 Hz bandwidth and push-button shunt calibration.
-
product
Pressure Calibration
We make pressure calibration easy! All you have to do is hand us over your gauge or meter! We’ll look after the rest, half inch, quarter inch, brass or steel fitting, we have the adapters to make it work.
-
product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
product
Calibration Services
A calibration industry leader since 1962, SIMCO provides trusted, high-quality instrument calibration services for thousands of organizations, including 15 of the top 20 global biomedical device manufacturers and 14 of the top 20 global aerospace and defense manufacturers.
-
product
Optical, Color And Electrical Integrated Test System
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
Our individually calibrated LED spectroradiometers provide fast and accurate results for actual light measurement applications. It only takes a few seconds to measure and view the results directly on the display, or use the optional analysis and automation software for more in-depth research. Using the HPCS6500 Spectroradiometer, you can measure any or all of the following optical quantities:
-
product
VisualIMPACT Software
CEAST VisualIMPACT software is designed to control CEAST Pendulums and Drop Tower Series, manage tests and offer a user-friendly interface when using the Data Acquisition System. It records force and absorbed energy data related to impacts, visualizes and helps analyze the results and calculates resilience. The operator is guided through parameters setup by means of tables describing strikers and specimens that are filtered according to the test type and international standard selected. In the case of instrumented tests, many possibilities for data analysis and visualization are made available. The results are shown through comprehensive and customizable graphs and can be filtered by break type (only specimens with a selected break type are shown). Working with groups of test, the software performs a statistical analysis, and the operator can pick and discard single test results. Different measurement units can be selected. It is possible to print reports and to export data totally or partially. Recent improvements include the possibility to set a number of user profiles, including graphic settings, default printing options, advanced parameters for data analysis and so on, switching quickly from one another when looking at results. The introduction of a new Data Acquisition System (CEAST DAS 64K) in the Impact product line has also triggered a number of new capabilities for the SW, which is now able to process a more comprehensive calibration file for instrumented tups and hammers and manage DAS configurations with a wider range of data acquisition channels.
-
product
Mobile ASA-Livestream Data Node for Main Inspection
CONNECT CUBE V3 | VP 185076
Maschinenbau Haldenwang GmbH & Co. KG.
The mobile data node is the right tool for quick and digital diagnosis of the brake system as well as for routine testing and calibration of all ASA livestream-capable brake testers. The plug & play solution can also be used for modern routine testing and calibration of brake test stands.
-
product
Thermo-Hygro-Barometer
C4141-4
Audio and optical alarm of measured temperature. Minimum/maximum memory. memory of minimum and maximum temperature included traceable calibration certificate. LCD backlight.With external air temperature-humidity probe on a 4 meters cable. Probe diameter is 18mm, length 135mm. Built-in indoor temperature and air pressure sensors.
-
product
10 MHz to 6 GHz/33 GHz LAN Power Sensor
U2049XA
Wide dynamic range (-70 to +20 dBm) for small signal measurements LAN/ Power-Over-Ethernet (PoE) connectivity for long distance remote monitoring (up to 100 meter)TVAC compliant for operation in vacuum Best-in-class long term drift performance Internal zero and automatic calibration saves time and reduces measurement uncertainty Easy measurement start-up with new intuitive BenchVue software
-
product
Automatic Trans. & Engine Oil Pressure Tester with 2 Gages
34550
Check oil pressure in automotive transmissions and engines.Adapters provide coverage of most domestic and imported cars and light trucks.Includes two gages: Large Gage calibrated from 1-600 PSI (0-4,000 kPa & 0-7.0 BAR) and Small Gage for lower pressure requirement 0-50 PSI (0-3.5 BAR)Large gage can be used for all applications and has hang-up hook. Small gage is for more accurate reading of engine oil pressure where maximum oil pressure does not exceed 50 PSI (3.5 BAR).Includes 6 feet of oil proof hose and 10 assorted fittings.
-
product
Long Wave Infrared Cameras
Calibir DXM640 Series
The Calibir uncooled Long Wave Infrared camera platform offers outstanding shutterless imaging performance and is optimized for Size, Weight and Power (SWAP). The Calibir DXM640 series features both shutter and shutterless operation and rapid image output on power up while delivering uniform response over the entire operating temperature range, making it ideal for thermal imaging applications requiring uninterrupted image acquisition. ULIS’s gen2 sensor offers an improved NETD and the updated calibration include customized gain correction on a per lens basis to offer even better image performances and response uniformity.
-
product
Rack Mount Thermometer Hygrometer
H3531R
Sensor H3531R is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Time to Amplitude Converters and Calibrator
A Time-to-Amplitude Converter (TAC) can achieve exceptional precision by using an analog technique to convert small time intervals to pulse amplitudes. When a timing application demands picosecond precision, a time-to-amplitude converter is a prime candidate. A time-to-amplitude converter is a productive solution for measurements less than 10 μs when time resolutions from 10 ps to 50 ns are required.
-
product
Coaxial Fixed Attenuator, DC to 12.4 GHz
8491A
The Keysight 8491A coaxial fixed attenuator provides precision attenuation, flat frequency response and low SWR over broad frequency ranges. The attenuator has type-N connectors and is available in nominal attenuations of 3 dB and 6 dB, as well as 10 dB increments from 10 dB to 60 dB. This attenuator is swept-frequency tested to ensure specification compliance at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.
-
product
Optical Signal Test Set
OST
The Optical Signal Test Set (OSTS) combines a state of the art optical power meter, a variable attenuator, and a high stability laser source. The unit is able to measure optical signals below -100dBm with 0.001dB resolution at a fraction of the size, power, and cost of competing solutions. Other features include data logging, programmable filtering, and auto calibration. Its small shielded ruggedized package, USB/power interface, and low cost make this unit perfect for lab use or for integration into larger systems.
-
product
Load Cell Indicator
Morehouse Instrument Company Inc.
This indicator can read mV/V and use free, custom Morehouse software to convert the mV/V units to engineering units with coefficient files from ASTM E74 or ISO 376 reports. This meter is often the choice for accredited calibration service providers that want high accuracy and convenience but do not want to break the bank.
-
product
Portable Temperature Calibrators
Portable temperature calibrators (dry-well calibrators) are electronic controllers which automatically, quickly and dryly supply a temperature. Due to the high reliability, accuracy and simple operation, portable temperature calibrators are particularly suitable as a factory/working standard for the automatic testing and/or calibration of temperature measuring instruments of all types. A major advantage is offered by the large sleeve diameters and the fast, stable temperature control, since, as a result of these characteristics, the time for calibration can be used very effectively.
-
product
Antenna, Octave Band Horn
EM-7020 | 1 GHz – 2.5 GHz
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
product
High-Voltage Dividers & Capacitors
Measurements International Ltd.
300 V to 300 kV, Outputs of 120 Vac, Primary Standard HV Measurements, Loss Measurement Systems, IEEE-488 Interface, Division Accuracy < 20 ppm, Calibration Period 3 to 5 Years.
-
product
Humidity
ACI humidity sensors are durable, accurate, reliable, and backed by a five-year warranty on the entire device. They can be field calibrated to reduce operating costs and paired with a temperature sensor(s) to reduce installation costs.
-
product
PAT Calibration Checkboxes
Seaward's special PAT calibration checkboxes are designed to provide a fast and simple means of confirming that test readings remain effective during those working periods between formal re-calibration.
-
product
Dial Indicators
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
product
PCI Strain Gauge Simulator Card, 6-Channel, 350 Ohm
50-265-016
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.