luminaire
-
Product
Precision Kelvin Holders
MH-4 Series
-
Integrating Spheres are essential tools for photometricresearch laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary.
-
Product
Ball Pressure Apparatus
BP-20
-
Is designed to perform tests specified in many standards where resistance of insulating materials to elevated operating temperatures is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaires, motors, connectors, etc. The test ensures that external parts of insulating material, the deterioration of which might cause the appliance to fail to comply with the relevant standards, are sufficiently resistant to heat.
-
Product
Near-field Goniophotometer
RiGO801
-
TechnoTeam Bildverarbeitung GmbH
Correct determination of the luminous intensity distributions (lid) of lamps and luminaires far within their photometric near-field range. Capture of ray data.
-
Product
GO-SPEX500 Goniospectroradiometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for all kinds of indoor lamps, flood lamps, road lighting lamps and all kinds of light distribution performance test, total luminous flux, luminaire efficiency and electrical parameters (voltage, current, power, power factor) measurement.Test data can be saved as IESNA(*.ies), CIBSE(*.CIB), EULUMDAT(*.LDT), CIE(*.cie), CEN(*.cEN) and other formats, which can be directly used as the input data of international general lighting design software.
-
Product
Compact Goniophotometer For Lamp Spread Angle Tester
-
Shenzhen Chuangxin Instruments Co., Ltd.
LCG-1600 Goniophotometrc System carries out measuring methods of fixed location and rotating luminaires. The measured luminaire is installed on the two-dimension rotating table, using “+” laser to make the luminaire lighting center superposed with the rotating center of rotating table. The mechanical equipment allows turning the tested luminaires around a vertical axis and a horizontal axis. When tested luminaires turn around horizontal axis, the detector which is at the same level with rotating table will measure the intensity of each direction at this surface. When rotating with vertical axis, the detector will measure the intensity at the vertical surface. The vertical and horizontal axis can be rotated continuously at ±180° or 0~360°. According to the measurement requirements, the system can be operated in C-γ coordinates. When getting intensity distribution data, computer will calculate other photometric parameters automatically.
-
Product
Power Over Ethernet (PoE)
-
Power over Ethernet (PoE) is a revolutionary technology that enables delivery of power over standard Ethernet infrastructure to facilitate quick and easy installation of WLAN access points, network cameras, IP telephones and other IP-based devices. The proliferation of Ethernet-connected devices such as Pan-Tilt-Zoom (PTZ) security cameras, 802.11ac and 802.11ax access points, LED luminaires and Internet of Things (IoT) appliances has created an unprecedented demand for more power. PoE is the key to efficiently, cost-effectively and reliably power network devices.
-
Product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
-
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
-
Product
Leakage Current Tester
TOS3200
-
The Leakage Current Tester TOS3200 is designed to perform leakage current (touch current and protective conductor current) tests on general electrical equipment but not medical electrical equipment.It enables you to conduct tests that conform to the requirements of the applicable IEC, UL, JIS, and other standards, as well as the Electrical Appliance and Material Safety Law. The memory in the main unit stores the 51 types of test conditions laid down in the IEC/JIS standards for information technology equipment, household electrical appliances, audio, video electronic apparatus, luminaires, motor-operated electric tools, and electrical equipment for measurement and control and in the Electrical Appliance and Material Safety Law, thereby enabling you to conduct standard tests with simple panel operation.
-
Product
Goniophotometer For Luminaries Intensity Distribution Curve
LCG-1800
-
Shenzhen Chuangxin Instruments Co., Ltd.
Mainly used to measure FL etc. When installing luminaires, the lighting center of luminare and the rotating center of rotating table shall be at the same position. In B- coordinates, luminaire axis is superposed with the horizontal axis of rotating table. In A- coordinates, luminaire axis is vertical with the horizontal axis of rotating table.
-
Product
Goniometer Systems
-
Our Goniometetric measurement systems are optimized to provide precise measurement of angle dependent spatial radiation properties of LED luminaires, lamps and other light-producing modules. Using a variety of photometric and spectroradiometric detector options, our goniometer systems achieve optical properties as a function of angle with accuracy, precision and speed.
-
Product
Absolute Luminous Flux Integrators
-
Photometric Solutions International Pty Ltd
The Absolute Luminous Flux Integrator (ALFI) is a special device for absolute measurement of the luminous flux output of lamps. It can also to measure the luminous intensity distribution of small lamps and luminaires.
-
Product
Rotation Luminaire Goniophotometer
LSG-1800
-
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
HAAS-1200 Accurate Array Spectroradiometer (Advanced Industry Grade)
HAAS-1200
-
Hangzhou Everfine Photo-E-Info Co., LTD
HAAS-1200 quickly and accurately measures the spectral power distribution in the range of 380nm-1000nm, and achieves the photometric, colorimetric and radiometric parameters of various luminairs and lighting sources according to the requirements of the International Commission on Lighting (CIE) standard publications.
-
Product
Lighting Reliability
-
LED/OLED package lifetime is highly dependent on thermal management, and LED lamp performance can be dependent on the luminaire in which it is installed. Lighting reliability test system for LED/OLED Products are widely used for normal /accelerated aging, lumen maintenance measuring, lifetime evaluation and temperature characteristic testing for LED/OLED products including LED package, array, module, OLED module and luminaires.
-
Product
Safety
-
Test Equipment to verify Safety, Quality and Compliance characteristics of electro-technical products as required by national and international safety regulatory agencies. These equipment are used to check Electrical Wiring Accessories, Electrical Home Appliances, Industrial Luminaires, Motors and components or parts used in such products. Several of these safety test equipment are common to many standards and are required for routine 100% test purposes to ensure product safety.
-
Product
Conversion Kit for Kelvin Holders
KC-4
-
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary
-
Product
Salt Spray Chambers
-
Weice Testing Instrument Co.,Ltd.
The WTS series of salt spray chambers are manufactured and designed to meet the high quality requirements and standards, such as ISO, JIS, DIN, ASTM, IEC, GB and SAE. They are used to test the resistance capabilities of materials eroded by brine, these materials may be used in Electrical Appliances, Electrical Wire, Accessories, Luminaires etc.
-
Product
Solar Simulator
Unisim
-
TS-Space Systems is the first company to pioneer the use of metal halide sources in solar simulators for photovoltaic testing. The high temporal stability and close spectral match combined with the ability to control the output spectrum via multiple separate wavebands means the Unisim solar simulator is the only solar research tool designed for the accurate measurement of multiple junction devices, including the new generation of four junction devices. As with all our Unisim solar simulators, they exceed the ASTM, IEC and JIS international standards for spectral match and temporal instability. Using the latest HMI and halogen luminaire technology, the Unisim solar simulator provides a highly stable area of illumination. The simulators also use cutting edge filter technology in order to provide the best spectral match available for AM0 and AM1.5. Further to this, the spectrum can be achieved via two, three or four separate spectral wavebands which allows a high degree of spectral control for research and development. Product support is very important to us. Training is provided at our premises where customers can take advantage of one-on-one tuition with the instrument designers and learn how to operate and maintain their tools. Extensive support via phone and email for the full lifetime of the instrument is included with every TS-Space Systems product.
-
Product
LT-500A Aging-Life Test System For LED Luminaires
-
Hangzhou Everfine Photo-E-Info Co., LTD
LT-500A system is widely used for normal /accelerated aging, lumen maintenance measuring, chromaticity shift measuring, lifetime evaluation and temperature characteristic testing for LED luminaires, arrays, and modules. The extrapolation of lifetime by programmable models is also available to estimate the lifetime of LED luminaires.
-
Product
Goniophotometer
-
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
Product
LT-300A Aging-Life Test System For LED Luminaires
-
Hangzhou Everfine Photo-E-Info Co., LTD
LT-300A system is widely used for normal /accelerated aging, lumen maintenance measuring, chromaticity shift measuring, lifetime evaluation and temperature characteristic testing for LED luminaires, arrays, and modules. The extrapolation of lifetime by programmable models is also available to estimate the lifetime of LED luminaires.
-
Product
Spring Impact Hammer IK Level Tester
IK01-06
-
The most of luminaires manufactory were request to do IK level test (Impact Protection), LISUN can supply the IK test instrument. IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
Product
IK Level Tester
IK07-10
-
IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).