Wind Tunnels
deliver specific air-stream to characterize air-flow's affect.
See Also: Wind, Tunnel, Anemometers, Wind Turbine, Wind Speed
-
Product
Wind Power Solution
EVO ACCIONA
-
The EVO ACCIONA is custom-made with firmware and fixtures designed specifically for Acciona turbines. These precisely designed fixtures make generator-to-gearbox alignment easy inside any nacelle – safeguarding reliability and optimizing the energy efficiency of the wind turbine.
-
Product
Wind Turbine Performance Lidar
Wind Iris
-
The Wind Iris is based on Leosphere's leading WINDCUBE pulsedLidar technology, and is the first remote sensor dedicated to turbine-mounted measurements. It measures the horizontal wind speed and direction from 40m to 400m upwind of the turbine. Real time and average data can then be transferred automatically or stored in a data logger.
-
Product
Tunnel Diode Zero Bias Detectors
-
A tunnel diode zero-bias detector is a device that converts microwave and millimeter-wave radio frequency (RF) signals into a DC voltage without requiring an external power source
-
Product
Wind Transmitters
-
Comptus wind speed and direction transmitters convert the sensor signals into electrical outputs suitable for connection to displays, computers, dataloggers, wireless transmitters, or other controls. Output options include: 0-1 mA, 0-1 V, 0--5 V or 4-20 mA. Power options include: 24 VAC, 120VAC, 230VAC, 12-24 VDC. Comptus transmitters come standard in a track mount for installation in existing enclosures. They are also available in NEMA rated enclosures. Please contact us for enclosure options.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
Product
Transformer Winding Resistance Meters
RMO TW Series
-
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Bobbin Winding Coil Turns Tester
SS108A series
-
Bobbin winding coil testers are used to test various coil of turns. Such as: generator winding turns, transformer winding turns, motor winding turns, inductor winding turns, contactor winding turns, relay winding turns, sparking winding turns, ignition winding turns, speaker voice coil, etc.