Fault
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-193A-002-HI
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
product
Primary Cable Fault Locating
Directional Impulse Detector
The Directional Impulse Detector ( D.I.D.) is a compact handheld detector used to locate primary cable faults by sensing the magnetic field generated by the current pulse from a high voltage discharge device (thumper). A meter deflection indicates the intensity of the received signal. No deflection indicates that you have walked beyond the fault or away from the cable.
-
product
Pen-based Fault Locator
*Find the breakpoint, bending or cracking*Find the fault of OTDR dead zone*Identification of fiber from one end to other end*Universal adaptor*Testing distance up to 8km*Lightweight, red laser output, both SM and MM available
-
product
Cable Fault Meter
A cable fault meter can locate open power cables, either live or dead (without current), with voltages up to 300 V. A cable fault meter can locate cables, circuits, short circuits and ground wires. To perform these functions, it is not always necessary to disconnect electrically sensitive devices or to disconnect the power from the cable which is being tested. Many cable fault meter devices can also locate ferrous and non-ferrous metals, wood and plastic with high degrees of accuracy.
-
product
Traveling Wave Fault Locator
XC-2100E
XC 2100E, a Fault Location System based on principle of travelling wave detection is the solution to above problem. It can detect not only permanent fault, but also transient fault within one tower span accuracy (with best accuracy of ±50 meters). It is a kind of Line Monitor for continuous monitoring of transmission lines and gets triggered whenever travelling waves are generated on line due to switching, lightening or fault.
-
product
Stimulus Induced Fault Testing
SIFT
SIFT allows for the analysis of numerous stimuli to identify speed, fault, and parametric differences in silicon. The heart of the SIFT technique revolves around intentionally disturbing devices with external stimuli and comparing the test criteria to reference parts or timing/voltage sensitivities. Synchronous interfacing is possible to any tester without any wiring or program changes. The system can be based on either a motorized probe station or portable microscope stand for test head applications.
-
product
Visual Fault Diagnostics and Repair System
ScanExpress Viewer
ScanExpress Viewer™ is a printed circuit board (PCB) CAD data & photograph visualization tool for boundary-scan test development, electronic manufacturing test, and product repair environments.When combined with ScanExpress ADO™ (Advanced Diagnostics Option) for detailed results from ScanExpress Runner™, ScanExpress Viewer displays fault coordinates and connected traces superimposed directly on a board photograph or CAD layout diagram for expedient repair.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Cable Fault Locator
TX2003
6 km (19,000ft) 0.5mtr dead Zone Selectable Cable Impedance Warble Tone Generator Rapid Fault Location Large 128x64 LCD with Backlight Scratch Resistant Display Environmental Protection IP54 CE Approved 3yrs Manufacturers Warranty 60 Hours Battery Life
-
product
USB-8501, 2-Port, Low-Speed/Fault Tolerant, USB CAN Interface Device
786307-01
The USB-8501 is a low-speed controller area network (CAN) interface for developing applications with the NI‑XNET driver. The USB‑8501 is powered over the USB bus and does not require external power. It excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals such as bus monitoring, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time for processing complex applications. The USB‑8501 is available with a three‑pin COMBICON synchronization connector for triggering and synchronizing the internal hardware timebase with other devices.
-
product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
Fault Locators
For the first time, you can detect the type of fault and locate the position of an electrical fault that causes intermittent or persistent circuit breaker trips, thus giving you the critical information needed to reduce call backs for circuit breaker trips.
-
product
Digital Fault Recording
SHERLOG
Fault recorder systems with a power quality analyser for comprehensively monitoring and assessing low, medium and high voltage networks in power plants and transformer substations. The measuring devices of the SHERLOG range make very high-resolution recordings of all the disturbances which occur in power supply systems. The behaviour of protection and switchgear devices during these system disturbances is recorded at the same time.
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
product
Fault Finder for Electrical Wiring Open / Short Circuit
FF310
42 V Ready: for use in the new generation of vehicles with mixed or single 42 Volt systems. Operates on DC voltages from 6 to 42 volts. Internally protected against power surges and overloads. 8" flexible probe allows reaching wires in congested places. Transmitter and Receiver LEDs show open or short circuit conditions.
-
product
Fault Locator
SNOOPi
SNOOPi employs a bespoke optical sensor to detect and discriminate between fault and natural gas.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
2.5mm Visual Fault Locator
3105
Anfkom International Co.,Limited
The 3105 Pen type VFL is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network. It includes:Finding the breakpoint, poor connections, bending or cracking in fiber optic cables.Finding the faults of OTDR dead zoneEnd-to-end visual fiber identification
-
product
PXI-8511, 1‑ or 2-Port, Low-Speed/Fault Tolerant PXI CAN Interface Module
780686-02
1‑ or 2-Port, Low-Speed/Fault Tolerant PXI CAN Interface Module—The PXI‑8511 is a fault-tolerant Controller Area Network (CAN) interface for developing applications with the NI‑XNET driver. The PXI‑8511 excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI‑XNET device-driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimize message latency and freeing host processor time for processing complex models and applications.
-
product
PCI Fault Insertion Switch Range for Differential Serial Interfaces
50-200/201
Pickering Interfaces, a leading supplier of modular signal switching for electronic test and simulation, is expanding its range of PCI Fault Insertion switching with the introduction of two new modules (models 50-200 and 50-201) designed for use with differential serial interfaces. PCI Fault Insertion Switch Cards for Differential Serial InterfacesThe new modules include the Differential PCI Fault Insertion Switch (model 50-200) which is designed for lower data rate serial interfaces such as CAN and FlexRay, and the High Bandwidth Differential PCI Fault Insertion Switch (model 50-201) which is designed for higher data rate serial interfaces such as AFDX and 1000BaseT Ethernet. Each module allows the introduction of fault connections that include data paths open, data paths shorted together, and data paths shorted to externally applied faults such as power supplies and ground. The software driver defaults to a protective mode where conflicting faults are prevented to avoid accidentally shorting unintended paths, such as power to ground. A separate mode allows complete freedom in setting fault patterns.
-
product
Fault Locator
REZAP FAULTMASTER
REZAP FAULTMASTER is an auto-recloser that keeps customers on supply during intermittent faults.
-
product
FiberScout | Fault Identifier & Singlemode Fibre Length Tester
TS21
The TS21 Fiber Scout was designed and developed by Yamasaki as a cost effective and simple solution for identifying faults and testing the length of singlemode fibers. This lightweight, rugged, dustproof and water resistant piece of test equipment can list up to 8 results at one time and has three brilliant functions.
-
product
Ground-Fault Location Products for Ungrounded Systems
When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.
-
product
Cable Fault Locator
TW3304N
Techwin(China) Industry Co., Ltd
The Perfect Handhold Tester Series Cable Fault Locator TW3304N is the most portable test instrument in the industry. It adopts the OTDR technical principles and integrates the powerful analysis software, which enables the TW3304N fiber ranger detect fiber faults location more accurate and easy.
-
product
Travelling Wave Fault Location Test Kit
PH Series
PH series travelling waveform fault locating relay/equipment test set is a new device to meet the needs of testing and verification for travelling wave fault location equipment and protection relay with TWFL function.
-
product
FAult Detector and OScilloscope 9 Functions in 1
FADOS9F1
Prot-Ar-Ge Industrial Project Design R&D Ltd. Co.
2 unique features are added to the FADOS9F1 over the FADOS71. First feature is the Programmable DC Power Supply; It can be adjusted between 0-16V and 20-1500mA with power output; the DC Voltage/Current graphs of the electronic card power supply can be produced. The second feature is the “IR Remote Temperature Measurement Sensor”; this sensor is used to find the components that heat up by drawing too much current. Using these two features together may reduce the time for trouble shooting some malfunctions by 5 to 10 times. These features can be used as a new technique for trouble shooting.
-
product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.





























