Insulation
-
Product
Manual PAT Testers
-
If you are looking for a manual PAT tester with a pass fail reading or a PAT tester with readings we have a solution for you. Carry out mains supply checks, IEC lead tests, Earth continuity tests at 200mA, Insulation resistance tests to 250V and 500V, and more with these popular testers. All of our manual PAT testers are available as kits to help you streamline the way you work.
-
Product
Digital Insulation Mult-Meter
8005 IN
-
Standard Electric Works Co., Ltd
● Microprocessor controlled.● Four insulation test voltages (DC) : 50V, 100V, 250V, 500V● The maximum insulation measurement range is 200G ohm @500V.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III
-
Product
Industrial Coatings, Platings, Insulators
-
Honeywell Aerospace Technologies
Honeywell has decades of experience developing materials for the extreme temperatures and stresses of aerospace applications. Now it’s making those specialized coatings, insulators and electroplating technologies available to customers in industries ranging from aviation to oil drilling.
-
Product
Analogue (1kV below) Insulation Tester
1800 IN
-
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages.● Color-coded scale.● AC voltage measurement.● Fuse protected.
-
Product
Insulation & Multifunction Tester (LCD Display)
1151 IN
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at Switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
-
Product
Insulation Multimeter
VA588
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
VA588 Insulation Multimeters combine a digital insulation tester with a full-featured digital multimeter in a single, compact.
-
Product
Digital H.V. Insulation Tester(15kV)
7016 IN
-
Standard Electric Works Co., Ltd
● Protection class: IP66 (Lid closed)● Test insulation resistance up to 30TΩ (30000GΩ).● Short-circuit current up to 5mA● Microprocessor controlled.● 30 insulation test voltages : 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV● AC/DC voltmeter (600V).● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) : 1~30 minutes● Auto-off.● Calendar.● Optical USB to RS-232 data transmission.● 200 measurement results can be saved in the memory and recalled on the display.● Safety standard : EN 61010-1 CAT IV 600V EN 61010-2-030 EN 61326-1
-
Product
Connector Test
-
A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.
-
Product
Oil Breakdown Voltage Tester
DTA 100 C
-
Insulating oil testing with the BAUR DTA 100 C. The BAUR DTA 100 C oil tester is designed for continuous operation in the laboratory and is characterised by the combination of extraordinary features. As a high-performance device with a test voltage up to 100 kV, with clear breakdown detection and absolutely reliable measurement results even across several measurement sequences, the BAUR DTA 100 C is the leading testing device for users in the electricity and other industries and in testing institutes.
-
Product
Resistor Calibration Box
RCB-411
-
Standard Electric Works Co., Ltd
● The RCB-411 is used to verify and proof High Voltage Insulation Testers. Both Analogue and Digital Insulation Testers can be calibrated.● Caution: a. Before testing, make sure the front panel, terminals are clean and dry. If not, wipe them with cloth. b. Use high voltage silicone wires. Otherwise the reading will be incorrect.
-
Product
Digital Insulation Testers
-
Precision Mastech Enterprises Co.
Specialized, high-voltage electrical tools used to measure the resistance of insulation in motors, cables, and transformers.
-
Product
20U (35") Insulated Bus Bar
BB-35-I
-
20U (35") insulated bus bar provides cabinets with recessed rail option and a convenient, isolated common grounding mechanism.
-
Product
Leaky Insulator Detector
LIDOR
-
The Leaky Insulator Detector (LIDOR) is two-piece hand held non-destructive inspection system which utilizes AC/DC Current sensor and Ultrasonic technology for predictive maintenance. The Leaky Insulator Detector (LIDOR) has a Flexible clamp sensor and Ultrasound Receiver.
-
Product
Digital (1kV below) Insulation Tester
2751 IN
-
Standard Electric Works Co., Ltd
● Timer for test function (count 3-5 minutes).● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338”) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● Data hold function● Auto power off function.● BS 16 edition.
-
Product
Installation Safety Testers
-
PeakTech Prüf- und Messtechnik GmbH
This innovative combination meter for testing electrical installations according to VDE 0100 convinces by its technical performance in the high-end range.With the large 3.5 "TFT color display all important safety checks as the RCD-, Voltage-, Loop-, Low-Ohm, Earth resistance and Insulation tests for annual safety-checks and newly installed systems can safely be carried out by the responsible electrical engineer.Since this new development was designed only according to the latest standards, the required measuring values can be even more convenient stored with an App (iOS / Android) via Bluetooth on the mobile phone, saved to an SD card or, when work is completed, from the internal data memory via USB connection to a PC.
-
Product
Enlarge Environmental Chamber
REXMED REC-250
-
MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
Insulation Resistance Meter
1503
-
The Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing.
-
Product
Power Line Purpose Tester
LX-221A+
-
Shenzhen Lian Xin Technology Co., Ltd.
·Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards .·Used to test single – ends ,double –ends ,three-ends power supply cords.·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,·Provide with RS 232 interfaces, can communicate with PC, easy to upgrade,·Provide personalized customization according to different requirements.
-
Product
High Voltage Insulation Tester
505
-
Simpson's Model 505 High Voltage Insulation Tester is capable of measuring insulation resistances from 10 kilohms to 1 teraohm with eight selectable test voltages up to 5000 V. As a safety feature, the insulation tester acts as an AC/DC voltmeter to measure the absence of voltage in networks up to 2000 V.
-
Product
Environmental Chamber
REXMED REC-280
-
MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
Electrical Safety Analyzer
19032
-
Chroma Systems Solutions, Inc.
Our Electrical Safety Analyzers combine Hipot, Insulation Resistance ( IR), Ground Bond (GB), Leakage Current (LC)/AC LC/DC LC, and Dynamic Function Tests. Savings can be up to 50% of production line space by not having to purchase and rack several safety test instruments. It also increases efficiencies of electrical safety testing and reduces associated labor costs.
-
Product
80-500V AC/DC Twin-Lead Circuit Tester
1927
-
Peaceful Thriving Enterprise Co Ltd
*Handy pocket-clip.*Bright neon indicator.*With UL and cUL Approval.*Insulated housing and test leads.*Check voltage on 80-500V AC/DC.*Built-in lamp will glow if circuit is live.
-
Product
Energized Distribution Insulator Tester
-
A sensitive voltmeter, the tester measures the difference in potential across each insulator in a suspect string. Comparative readings from satisfactory strings in the same operating situation quickly indicate the state of every insulator in the string being tested.
-
Product
Test Capabilities
-
Eltek International Laboratories
ELTEK Labs has conducted more Electrical Insulation Systems (EIS) and Component Compatibility Testing (CCT) than all other laboratories worldwide combined. ELTEK Labs is proud to be a Third-Party Testing Laboratory for internationally recognized certifying bodies.
-
Product
EOL Testing of Starter-Generator Units (ISG)
-
Series test rig for starter-generator units (ISG)*High voltage test*Insulation resistance measurement*Temperature sensor control*Short circuit test*EMF test*Performance measurement*Manual loading and contacting
-
Product
Digital (1kV below) Insulation Tester
1160 IN
-
Standard Electric Works Co., Ltd
● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm ( 2.677” × 1.338” ) large LCD display.● LCD backlight display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● Auto ranging.● Fuse protection.● Data hold function.● BS 16 edition.
-
Product
Insulation Oil BDV Tester
-
Wuhan Fanke Transformer Manufacture Co., LTD
Insulation Oil BDV Tester
-
Product
Hipot Testers
Hypot® Series
-
The Hypot Series sets the standard for safety and efficiency in production line Hipot Testing. Whether your application requires AC Withstand tests, DC Withstand tests, or Insulation Resistance tests, The Hypot Series provides innovations that will allow you to begin achieving best practices for safety and efficiency without the need for an expensive automated test system or connection to a PC. You can even connect the Hypot Series with the HYAMP Series to form a seamless safety compliance system for Hipot and Ground Bond Testing.
-
Product
Digital Insulation Testers
-
Cut unscheduled downtime and reduce shock hazards by testing wires, cables, transformers or entire electrical systems.





























