Insulation
-
Product
AC High Voltage Break Down Tester
-
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
Product
Digital Insulation Tester
1550C
-
The Fluke 1550C performs digital insulation testing up to 5 kV, and makes data collection easy through the Fluke Connect™ wireless app. Remote operation lets you spend as little time as possible in potentially hazardous zones.
-
Product
Analogue (1kV below) Insulation Tester
2732 IN
-
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on "low ohms" : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Designed for meet international standards.● Supplied with high quality test leads.● BS 16 edition.
-
Product
AC Ground Bond Tester
446
-
Our 446 model is a 4-in-1 tester with AC Hipot, DC Hipot, Insulation Resistance, and Ground Bond capabilities. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application. The 446 is equipped with multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Add to user safety by equipping your tester with Personal Protective Equipment (PPE) via the built-in safety interlock.
-
Product
Insulation & Multifunction Tester (LCD Display)
4167 MF
-
Standard Electric Works Co., Ltd
● High Quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Two insulation test voltages(DC) : 250V and 500V.● Alternation voltage measurement.● Battery life indicator.● Fuse protected.
-
Product
Withstanding Voltage/Insulation Tester
-
AllWin Instrument Science and Technology Co., Ltd.
W to I, I to W automatic conversionVFD display
-
Product
Multi-Zone Temperature Chamber
MZTC
-
Is a battery test chamber with 8 independent temperature chambers in 1 for cells up to 60A. Insulation and protection between each chamber provides greater temperature control and a safe testing environment by isolating each cell or pair of cells, as well as making connections easy.
-
Product
Insulation & Continuity Multimeter
NEPTUNE
-
NEPTUNE is a mix of technology including an instrument for electrical safety testing (insulation up to 1000V and continuity with 200mA), a Harmonics analyzer and a TRMS multimeter.
-
Product
10W to 100W - Single Output
DRL Series
-
*High Efficiency, up to 90%*Low Profile for Building Automation*Class II Double Insulation*ErP Compliant Design*Low No Load Power Consumption*UL 1310 Class 2 Compliant*SEMI F47 Compliant
-
Product
Dielectric Loss Tangent Testing Instruments
-
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
Product
Digital Insulation Tester
SK-3502
-
125V/250V/500V/1000V, Comparator Function., Data Memory (up to 100 data)., Low Resistance Measurement., AC/DC Voltage Measurement., Enhanced Safety Functions.
-
Product
5-50V AC/DC Voltage Tester
1930A
-
Peaceful Thriving Enterprise Co Ltd
*Reinforced casing.*With cETL Approval.*Check voltage on 5-50V AC/DC.*Insulated housing and test leads.*Pocket clip for added convenience.*Built-in LED indicator will glow when voltage is present.
-
Product
Hipot Tester
NX Hipot+
-
50 to 1500VDC Hipot Testing, 50 to 1000VAC (optional), Expandable to 1024 test points, 5Mohm to 1Gohm Insulation Resistance, Simple 4-button user interface, Tests for continuity and shorts, Tests a variety of components, Precision resistance measurements, Continuous high speed scanning for real time complete status information of harness assembly progress, Keyed security access and control, Built for rough industrial environments, 2 serial ports for connection to printers and scanners, Standalone operation, Uses a high capacity memory card, Available from 64 to 1024 test points, Networkable
-
Product
Partial Discharge Testing Equipment
AR700
-
PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.
-
Product
HV Test System up to 20000 Volt
-
Insulated test booth with large space for test items. 2 banana sockets for AC connection and 4 banana sockets for the DC connection of the DUTs. IC’s are tested in a long-term test. These are checked in an oil bath so that there are no air gaps to reduce the insulation. Maximum voltage 20 kV. Therefore, insulation tests must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.
-
Product
Mineral Insulated Extensions
-
The extreme operating conditions in which Photonis neutron and gamma detectors operate can lead to deterioration of organic insulated cables, resulting in signal degradation which often requires cable repair.
-
Product
Digital H.V. Insulation Tester(12kV)
7012 IN
-
Standard Electric Works Co., Ltd
● Protection class: IP66 (Lid closed)● Test insulation resistance up to 20TΩ (20000GΩ).● Short-circuit current up to 5mA● Microprocessor controlled.● 24 insulation test voltages : 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV ● AC/DC voltmeter (600V).● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) : ● 1~30 minutes● Auto-off.● Calendar.● Optical USB to RS-232 data transmission.● 200 measurement results can be saved in the memory and recalled on the display.● Safety standard : EN 61010-1 CAT IV 600V EN 61010-2-030 EN 61326-1
-
Product
Oil Breakdown Voltage Tester
DTA IL
-
Insulating oil testing with the BAUR DTA IL. The BAUR DTA Inline is a high performance and reliable oil tester for continuous testing of the breakdown strength of insulating oils during production (inline tests). The combination of extremely short switch-off times during breakdowns and the easy oil sample handling facilitate high quality statements and conclusions on the insulating oil quality.
-
Product
Earth/Ground Resistance Tester
DE-5030
-
Earth resistance range0~12 / 0~120 / 0~1200 Normal operation conditionsBattery voltagein range of "BATT.GOOD" Earth voltage measurementmax. AC 30V Output current3mA Response timewithin 1 sec. Insulation resistancemin. 100M / DC1000V between input terminals and case Withstand voltageAC3700V (50 / 60Hz) for 1 min. between input terminals and case Battery Check Battery1.5V x 4 Safety standardIEC 61010-1 CAT.III 300V IEC 61557, IEC61010-031
-
Product
Relaying Current Transformer Analyser
-
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
Product
Digital (1kV up) H.V. Insulation Testers
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.
-
Product
Partial Discharge Testing Equipment
3i
-
The portable multipurpose 3i device (Intellectual Insulation Indicator) is for eff ective high-voltage equipment insulation monitoring on-line. The 3i device measures and analyses partial discharges (PD). For eff ective PD measurement and noise rejection, there are two types of sensors used in the device: the acoustic sensor and the TEV sensor. Both the sensors are built into the device case, and so do not need any connection cables. The device is supplied in a strong metal case; at the faceplate there are the colored screen and two buttons: power button and function button.
-
Product
Insulators
-
LBA Technology offers a wide range of styles of high power radio frequency (RF) feedthrough, standoff, and tower insulators.
-
Product
DC Insulation Testing
-
Weshine Electric Manufacturing Co., Ltd
Cable harness tester is used for test and measure wire cable harness,wire harness, like as : auto cable, audio cable, power cable, network cable, telephone cable, USD cable, HDMI cable,video cable, etc. .
-
Product
Insulation Resistance Measurement
MD 15KVR
-
The digital insulation tester model MD-15KVR is Megabras' cutting edge insulation analyzer equipment and it is one of the most complete and sophisticated available in the international market. A powerful software allows for further analysis of tests results, including features such as graphical representation and automatic report generation. Its proven technology provides safe, reliable and accurate measurements of insulation resistances up to 15 TΩ, with 4 pre-selected test voltages, 500 V - 5 kV - 10 kV - 15 kV. Other test voltages may be selected in steps of 25 V, 100 V or 500 V.
-
Product
Programmable Withstanding Voltage & Insulation Test
LS9923
-
LS9923 programmable withstanding voltage & insulation test system is high-performance testing device special for AC&DC Withstanding Voltage and Insulation Resistance Test, It allows setting the output voltage. The warning value,testing time and some other parameters can be set in the screen.It with a variety of automatic test functions. The testing is quick and high accuracy which is not only applied in the production line but also in the develop research.
-
Product
Electrical Safety Testers
-
A high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
Product
Power Quality, Ground Resistance & Insulation Testers
-
Improving energy efficiency, reducing downtime, and prolonging the life of your equipment are some of the ways you can save money with Amprobe tools.
-
Product
35U (61") Insulated Bus Bar
BB-61-I
-
35U (61") insulated bus bar provides cabinets with recessed rail option and a convenient, isolated common grounding mechanism.