HIgh Current
-
product
Brute High Current Probe
P4301-2F
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
Brute High Current Probe
P4301-1Z
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
HPC High Current Probe
HCP-13
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Alternate 24.00 (680.00) - 96.00 (2722.00) Godzilla High Current Probe
HC375F-6
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Godzilla High Current Probes, 150 Amp
HC500
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Brute High Current Probe
P4301-1W
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
Godzilla High Current Probe, 100 Amp
HC375
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
High Current SMU Family 2000 A
AXC76xx
Generate very short, fully regulated current pulses from 2 ms to DC with up to 2000 A. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
product
High Current Comparators And Power Supplies
Designed in 3D, this custom unit fills the gap between the comparator manufacturers and the production floor. Vidac Solutions does not manufacture CT Comparators, but this unit (and others like it) are used to provide the complex high-current switching, buss-work, source current supply into an enclosure that fits into the production line and provides a safe, ergonomic and easy to use machine for the operators.
-
product
8-Ch SPST 20A-250VAC High Current
YAV90087
8 power relays Switching 20A 250Vac PNP Outputs para control or YAV90304 control CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
High AC Current Capacitors
HK Film Capacitors offer a selection of High AC Current Capacitors ( continuous duty) with Temperature up to +105C
-
product
Impulse Semiconductor High Current Integrated
Transmission Line Pulse Test System
The Impulse Semiconductor High Current Transmission Line Pulse (TLP) test system is the tool of choice for extracting ESD parameters for transient protection devices in a package, or at wafer level. With accuracy better than 100 milliohms at 40 amps peak current, the Impulse high current TLP is specially tailored to the needs of today's ESD device designers who must accurately measure low values dynamic resistance irrespective of breakdown voltage.
-
product
High AC Current Capacitor
LC1/LC2/LC3-AN
Induction Heating Processing Equipment, High Current Welding, High Power Resonant Circuits, Motor Controls; Oscillating, Bypass, Coupling circuits, High AC Current applications, High-Frequency AC Filter and Medium Frequency Power applications.
-
product
High Current / High Temperature Spring Probes
We have spring probes, which can be used for high temperature and high current test under 200 degree and shows high performance in them.
-
product
High Current Conditioners
IsoTek’s unique Direct Coupled Design system offers extremely low impedance high current clean power for the hardest of loads.
-
product
Uni-Therm High Current Electrosurgical Analyzer
A unique high power low inductance load bank enables performance testing up to 8 ampere RMS with a duty cycle of up to 100% making the analyzer an extremely versatile test instrument for calibrating and performance testing of conventional and high power electrosurgical generators. The load bank allows testing in a range of 0-5115 with a resolution of over 1000 steps providing high detailed power profiles. The Rigel Uni-Therm also advocates safe working practise by providing all necessary resistors within a single enclosure.
-
product
High Current Resistance Measurement Systems
Measurements International Ltd.
Modular Designed Base Unit with Expanded Capabilities to 10,000 Amp, Complete Turn-key System, Resistance and Temperature Curves, Complete Measurement Systems Available, Proven Technology.
-
product
High Current Probes
The maximum continuous current rating of a spring probe is determined by its design, size, and construction. Typical probes are rated from 2 to 8 amps maximum continuously current at working travel. While this is sufficient for most board test applications, higher current applications will require a much more solid and rugged probe to withstand current capabilities of 10 to 150 amps and beyond.Another high current solution is our feed-through plunger probe line. As the name already describes, the plunger moves right through the probe and is made from a single piece, reducing the internal resistance of the probe to a minimum.
-
product
High Current capacity testing from Intelligent Charging
CT75A
A UK-based helicopter manufacturer wanted high capacity testing capability for their helicopter batteries and came to Intelligent Charging for a Special Unit. As a result of the above requirement, Intelligent Charging designed and built this new capacity testing unit to add to our extensive range of intelligent battery charging and capacity testing products. With up to 100.0A capacity testing capability this model will satisfy the most demanding aviation battery.
-
product
High Frequency Current Transformer
HFCT
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
product
AC / DC Current Probe, 100 KHz, 100 A
1146B
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
product
High Current Test System
HIGHVOLT Prüftechnik Dresden GmbH
High current test systems are used to test the thermal stability of equipment and components. The test system induces a current in the test object causing it to heat up. Therefore, the test object is designed as a shorted circuit. The high current test system measures the temperature of the test object at various points, in addition to the current. As a special feature, the temperature that the test object should reach can be specified and the amount of the current can be automatically calculated by the HIGHVOLT test system.
-
product
High Current SMU
Source and Measurement Units (SMUs) are devices that generate voltages or currents and can measure them simultaneously using the integrated measurement units (VMU, CMU).High current SMUs operate as a regulated power source and are able to generate very high output currents as pulses.
-
product
High-Voltage Differential Probe, 70 MHz
N2891A
Use the N2891A 70-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2891A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to ±7000 V of differential and common mode voltage.