Voltage Standards
-
Product
DC Power Source for Standard Lamp
DC502
-
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA
-
Product
Standard Transmitter
Tipix 2200
-
The TIPIX 2200 is a transmitter purposely designed for deep Induced Polarisation or Resistivity sounding investigations. This transmitter is generally used together with V-Fullwavers or Elrec Pro receivers. This entry-level instrument has been designed for an ease of use and for a good productivity together with a strong protection against misuse. This very robust device has proven to be reliable even in very cold weather (up to -40°C) or in wet environment. It is able to inject up to 2200W in the soil and to inject up to 13A, so that it is suitable, even on conductive soils, to measure resistivity and IP at medium range depths. It is powered by standard generator.
-
Product
5k Voltage Probe (set Of 3)
5KVPSet
-
5KVPSet is a set of three voltage probes that allow direct connection to up to 5,000 Vrms 3 phase power.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-F200-1
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
MMI-DVI, Fixtures with Higher Voltages
100290
-
The MMI-DVI is a good basis for fixtures with higher voltages. The MMI-DVI is made of NON-dissipative plate material and can therefore be used in the low-voltage range (up to 1000V AC / 1500V DC). The earthing package included is an important component. This is because the housing earthing, the earthing connection and the earthing test ensure that the safety standards are met. The solenoid interlock and the safety switch ensure access protection.
-
Product
Impulse Voltage Generator
-
Shanghai Sanki Electronic Industries Co., Ltd.
Impulse voltage generator Impulse voltage generator is mainly used for test products such as power equipment to perform lightning impulse voltage full wave, lightning impulse voltage chopping, operating impulse voltage wave and steep wave impulse voltage test, to inspect insulation performance. The technical indicators comply with national standards and IEC standards.
-
Product
Low Voltage Holiday Detector
M1-AC
-
For use such as: Coatings, in-plant environments, rebar, pipelines, sheet materials coated with thin film under 20milsa,
-
Product
Multiparameter CTD with a Wide Choice of Standard Sensors.
MIDAS CTD+
-
Featuring Valeport’s latest 400 Series electronics, the CTD+ will sample all fitted sensors at exactly the same instant, at up to 8Hz. Advanced setup software allows a variety of sampling regimes including burst modes, delay starts and conditional sampling. Available with up to 64Mbyte memory and internal battery pack, as well as a selection of real-time output formats, the CTD+ may be used with Valeport’s own water bottle carousel.
-
Product
70-440V AC Non-Contact Voltage Detector With Buzzer
1966A
-
Peaceful Thriving Enterprise Co Ltd
*Check voltage on 70-440V AC.*With CE, cUL and RoHS Approval.*Operates by two LR44 1.5V batteries.*LED will glow if AC voltage is present.*Check for proper ground connection of electrical appliance.*Test electrical lines, cables, sockets, fuses, switches and etc.
-
Product
STANAG3910/EFEX Test And Simulation Module for Standard Ethernet
ANET3910
-
STANAG3910/EFEX Test and Simulation module for Standard Ethernet. The ANET embedded Linux Operating System gives the unique capability to run the optional PBA.pro Engine right in the box. Another option is the ANET-ADK onboard software development kit where users create run-time applications (e.g. STANAG3910/EFEX to Ethernet Converter, STANAG3910/EFEX to Ethernet Gateway) to execute right in the box. For wireless applications, an ANET compatible USB Wifi dongle is optionally available.The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Medium Voltage Distribution And Grid Automation
-
We lead the way when it comes to safe, energy-efficient, and highly available power distribution solutions for low and medium-voltage electrical installations.
-
Product
PC Controlled Low Voltage Testers
-
PC Based Testers Low Voltage Introduction. The PC based analyzers provide high-speed testing for wire harnesses, backplanes, and printed-circuit boards.
-
Product
Parallel Interface Voltage Output D/A Converters
-
Analog Devices offers a large portfolio of parallel interface voltage output D/A converters (DACs). We provide precision, fast settling, rail-to-rail micropower VOUT D/A converters, with resolutions of 8 bits up to 16 bits, single-channel to 40-channel density, and a unipolar or bipolar supply. These devices are used in a wide variety of applications such as process control, automotive test equipment, or digital gain and offset adjustment.
-
Product
Standard Gain Horn Antennas
-
Linear polarized Broadband Horn Antenna (Brass with Plastic mounting body) for Receive and Transmit Applications.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4F
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2B40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
AC Voltage Tester
-
AllWin Instrument Science and Technology Co., Ltd.
1. AC voltage tester2. TFT LCD3. PLC,RS232C,RS485 interface4. MCU control technology
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3E
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4T
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
NanoLattice Pitch Standard (NLSM)
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of CD-SEM and Atomic Force Microscopes (AFM). Make the grade, with the only pitch standard of its kind available below the 130 nm node.
-
Product
sbRIO-9229 , Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
780874-01
Voltage Input Module
Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9229 performs differential analog input. The sbRIO‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Non-enclosed modules are designed for OEM applications.
-
Product
Dual Channel High Voltage Linear Amplifier
F10AD
-
his unit contains two independent F10A amplifiers that share common ground reference and power supply.
-
Product
Oil Based Resistance Standards
-
Precision electrical resistors designed for high-accuracy resistance calibration in fluid/oil baths or in air.
-
Product
Voltage Controlled Phase Shifters To 3200 MHz
-
Pulsar's Voltage Controlled Phase shifters utilize a DC voltage to control the phase of the RF signal applied. These phase shifters utilize varactor diodes to produce the necessary phase requirements. Phase of the 180 and 360 degree designs are available, and phase can be controlled with a DC voltage 0-20 Vdc. Modulation of these phase shifters is typically 100 kHz, and maximum input power is +5 dBm.A wide variety of package styles are available, such as plug-in, flatpack, TO-cans, and connectorized housings, though the most popular are the miniature surface mount packages. Surface mount packages are available on tape and reel, for automated assembly techniques.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3G
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Stand Alone Low Voltage Tester
Model 64×2
-
Internal Memory: 8 program locations without test point labels or 2 program locations with test point labels. Removable Memory: 16 program locations without test point labels, or 4 program locations with test point labels.
-
Product
NI-9224, ±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783862-01
Voltage Input Module
±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9224 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9224 is simultaneous sampling with two options for filtering a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39T15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50