Product
PXIe-4499, 204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module
781370-01
Analog Input Module
204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module - The PXIe‑4499 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4499 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4499 delivers simultaneous sample on all channels. In addition, the PXIe‑4499 includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
PXIe-6259, PXIe, 32 AI (16-Bit, 1.25 MS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module
779778-01
Multifunction I/O
The PXIe-6259 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
2-18GHz Instantaneous Frequency Measurement Unit
DR024-F2
-
Teledyne Defence & Space’s Instantaneous Frequency Measurement (IFM) module, also known as a Digital Frequency Discriminator (DFD), offers high speed frequency measurement across the full operating bandwidth.The IFM measures the frequency of RF signal present at its input and presents a result at its output as digital data. The RF input signal is conditioned by an RF amplifier that provides sufficient drive for the frequency resolving circuits. The raw video from the resolvers is digitised and processed into the required output format. There is additional timing and control circuitry which initiates the measurement process and provides handshake data to the host system processor.
-
Product
8AI Modbus RS-485 Remote I/O
ND-6117
Data Acquisition Module
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
Product
Video CODECs
ADV7202
-
For designers requiring complementary high precision, high speed video digital-to-analog and analog-to-digital converters, Analog Devices offers a single generation of video codecs. Designed to provide analog video input/output capability for proprietary video systems, ASICs, or FPGAs, the ADV7202 supplies raw video conversion and basic analog signal processing and conditioning to allow highly efficient, well partitioned systems architecture.
-
Product
PXI-6229, 32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module
779115-01
Multifunction I/O
32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6229 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-01
Sound and Vibration
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
SLSC and CRIO Modules and Accessories
Module
Our approach to delivering a high-quality Aerospace, Automated Test Equipment (ATE) asset begins with leveraging National Instruments hardware and software standard platforms. Beginning with high quality instrument platforms for standard Input and Output (I/O), we leverage NI’s PXI and Compact RIO platforms. Extending these system is NI’s unique platform for Switching, Loads and Signal Conditioning (SLSC), which allow the standard I/O to be customized for high performance aerospace industry applications.
-
Product
USB Signal Conditioning Products
-
Signal conditioning can include amplification, filtering, converting, range matching, isolation and any other processes required to make sensor output suitable for processing after conditioning. It is primarily utilized for data acquisition, in which sensor signals must be normalized and filtered to levels suitable for analog-to-digital conversion so they can be read by computerized devices.
-
Product
Analog Functions
-
Analog Devices designs amplifiers and linear products that deliver high performance and high value. We combine circuit design, manufacturing process innovation, and applications expertise to create products that simplify signal conditioning design.
-
Product
PXI-6280, 16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Hybrid, Multifunction I/O Module
779120-01
Multifunction I/O
16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Multifunction I/O Module—The PXI‑6280 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Accelerometers - Special Purpose
-
Analog Devices accelerometers and iSensor® MEMS accelerometer subsystems provide accurate detection while measuring acceleration, tilt, shock, and vibration in performance driven application. Our portfolio leads the industry in power, noise, bandwidth, and temperature specifications, and offers a range of MEMS sensor and signal conditioning integration on chip. Our MEMS-based Circuits from the Lab® reference designs have been built and tested by ADI experts to help you jumpstart your next system design.
-
Product
PXI-6251, 16 AI (16-Bit, 1.25 MS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module
779117-01
Multifunction I/O
The PXI-6251 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Block Up-Converter
-
RF Lambda’s block up-converters are used to convert IF frequencies up to RF. They can include power amplifiers for high output power and signal conditioning such image rejection as required by the system.
-
Product
Signal Conditioner
ClipX
-
Fast and digital signal conditioning for force sensors, load cells, torque sensors, pressure transducers, as well as temperature and standardized signals (current/voltage). Guaranteed measurement accuracy, even in harsh industrial environments with electrical interferences.
-
Product
Power Measurements Conditioner
-
The Power Measurements Conditioner provides voltage and current signal conditioning for a supported data acquisition module or device to make up to four simultaneous power measurements per conditioner. It also includes attenuation for voltage channels up to 2,000 V and has power, communication, and signal lines for current measurements from current transducers.
-
Product
Displacement Transducers - DC Operation
-
Columbia Research Laboratories
The Columbia DDCP Series Transducers are completely self-contained displacement measurement systems that operate from a low voltage DC power supply or battery. They permit highly accurate readout and recording of an output signal directly without auxiliary signal conditioning electronics.
-
Product
Data Acquisition Modules
Data Acquisition Module
Advantech''s data acquisition modules and ethernet I/O modules provide ideal industrial control and measurement solutions for harsh environments and demanding applications. With wide operating temperature ranges and multiple mounting methods, Advantech''s ADAM series, such as RS-485-based and ethernet I/O, can be implemented in diverse applications. The Advantech ADAM-3000 series consists of cost-efficient, field configurable, isolated signal conditioning modules that can be easily installed to protect instruments and signals from the harmful effects of electrical interference.
-
Product
PXI-6289, 32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module
779123-01
Multifunction I/O
32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6289 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
PXI-6289, 32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Hybrid, Multifunction I/O
779639-01
Multifunction I/O
32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6289 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784397-01
Sound and Vibration
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
4-channel Strain Gauge Amplifier Module
SCS-824
-
The SCS-824(5)(6)(7) provides 4 channels of strain gauge inputs for the SCS-800 signal conditioning system. It accommodates most strain-gauge types, from single-element quarter bridges to 4-element full bridges. Using included SystemView software, you can adjust excitation voltage, input gain, offset nulling, and all other key functions
-
Product
PCI-6284 , 32 AI (18-Bit, 625 kS/s), 48 DIO PCI Multifunction I/O Device
779110-01
Multifunction I/O
32 AI (18-Bit, 625 kS/s), 48 DIO PCI Multifunction I/O Device - The PCI‑6284 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
VXI Module
VDSP-31
-
The VDSP31 is a VXI based, multi-channel data acquisition system and digital servo control module. The VDSP31 offers a complete solution for high performance closed loop applications. The VDSP31 has been designed to solve specific problems related to the control of hydraulic actuators. Signal conditioning modules can be combined on a per channel basis to configure the VDSP31 for load or displacement feedback.
-
Product
In-Line IR Sensor
ILA
-
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
Product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
782000-02
Sound and Vibration
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
779521-01
Strain/Bridge Input Module
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
Product
IOS Subsystems
-
Analog Devices has been the leader in isolated signal conditioning for more than 20 years. ADI IOS products feature complete modular solutions for industrial signal conditioning. These products are the benchmark for isolated signal conditioners, with price and performance unmatched in the industry.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
Analog Output Module
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
32-CH 12-Bit 100 kS/s Isolated Analog Input Card
PCI-9113A
Analog Input Module
ADLINK PCI-9113A is a 32-CH, 12-bit, 100 kS/s isolated analog input card. The PCI-9113A provides analog inputs with 3 programmable input ranges for both bipolar and unipolar inputs. The 32-CH single-ended analog inputs can be converted to 16-CH differential analog inputs, which improve the noise rejection in harsh industrial environments. The analog inputs are isolated from the PC's system ground. This feature not only protects the PC from being damaged from surges on the signal lines, but also eliminates ground loops and common-mode problems commonly seen in industrial measurement applications. The PCI-9113A provides custom circuit area for input signal conditioning. Either signal attenuation or filtering can be applied on per channel basis. With all the features, ADLINK PCI-9113A delivers cost-effective and reliable data acquisition capabilities for ATE, sensor monitoring, data logging, power transmission, and a broad variety of industrial measurement applications.