Infrared Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
Electronic Calibration Module (ECal), 67 GHz, 1.85 Mm, 2-Port
N4694D
Electronic Calibration Module
The Keysight N4694D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4694D is a precision 2-port ECal module that supports 1.85 mm connectors up to 67 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4694D is included for securing your ECal module and accessories.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
Mechanical Calibration Kit
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
Calibration Cable
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
Product
1 Mm Calibration Kit
85059B
Mechanical Calibration Kit
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
Electronic Calibration Module
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Electronic Calibration Module (ECal), 40 GHz, 2.92 Mm, 2-port
N4692D
Electronic Calibration Module
The Keysight N4692D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4692D is a precision 2-port ECal module that supports 2.92 mm connectors up to 40 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4692D is included for securing your ECal module and accessories.
-
Product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
Electronic Calibration Module
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
Mechanical Calibration Kit
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
Mechanical Calibration Kit
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
7-Meter Laser Head Cable
10882B
Calibration Cable
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
Infrared Camera
VarioCAM HD head 900
-
With its 3.1 megapixels in IR-format the worldwide unique infrared system VarioCAM ® HD head 900 gives a new definition to the premium segment of uncooled industrial cameras and guarantees for precise infrared recordings in brilliant photographic quality.Image format: (2,048 x 1,536) IR pixel optomechanical MicroScan feature Recording and storage of IR frames rates with up to 240 Hz GigE- and process interfaceRugged light metal housing IP67*
-
Product
Infrared Thermometers
-
The Fieldpiece Non-contact Infrared Temperature Accessory with Laser Sight, model ATIR3, collects infrared energy (IR) and converts it to a mVDC signal that is proportional to the temperature being measured. The temperature measured is the average of all the temperatures in the 8:1 cone of viewability. The closer you are to the target, the smaller the area measured. The further away, the larger the area. The digital, non-contact ATIR3 converts the Fieldpiece “Stick” series meter, or electronic handle to a one-piece infrared, or IR, thermometer.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Infrared Thermometers
-
Our infrared thermometers make it possible to measure a temperature without contact by way of determining an object emitting infrared radiation. Here you will find Infrared Thermometers for measuring temperature without contact and contain a targeting light to ensure the correct surface area is being measured. An infrared thermometer can only measure the temperature of exposed surfaces and not through glass. Some infrared thermometers possess a preset emissivity value, and others allow the user to choose the emissivity value depending on the surface material being measured, whether it's paper, wood or metallic surfaces.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (f)
85561A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight.
-
Product
Diagonal Measurement Kit
10768A
Mechanical Calibration Kit
The Keysight 10768A Diagonal Measurement Kit is designed for use with the Keysight 5530 Laser Calibration System. It allows linear measurements to be made on the four body diagonals of a machine tool's working volume. These measurements document the machine's capability and quickly perform a complete check of volumetric positioning performance. In addition, long-term drift tests can be performed over hours or days, showing possible effects of temperature on geometry.
-
Product
Infrared Thermometer
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
Thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
Electronic Calibration Module
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Infrared Thermometers
-
Makes non-contact temperature as quick and easy as pointing the laser and pressing a button. Unique pocket-sized model available with additional temperature and flashlight feature-set.
-
Product
Infrared Analyser
-
The Infrared LED Analyser contains a specially selected and processed fibre that must be used in conjunction with the Optical Head, which is specifically designed for infrared LED testing. Ideal for security and monitoring applications. The analyser is available in 3, 10 and 20 channel configurations. Interfaces for this are USB, RS232 or daisy-chaining - several LED analysers can be connected to each other via the daisy-chain connections.
-
Product
Infrared Thermometers
-
Two specifications tell you nearly everything you need to know about any infrared (laser) thermometer: its measurement range and its distance-to-spot (D:S) ratio. The wider the range and the higher the D:S number (a measure of its optical resolution), the better the instrument. Infrared Thermometers (IRTs) with lower numbers are perfectly adequate for simple tasks like spot-checking food temperatures and energy auditing such as the IRT207 Non-Contact Infrared Thermometer. Higher-priced infrared thermometers intended for industrial users may have a SKU that ends in "K" such as the IRT850K Ultra-Wide-Range Infrared Thermometer with K Port and Adjustable Emissivity. The "K" indicates that it can accept inputs from a "K" type thermocouple probe used to measure temperature on-contact.
-
Product
Calibration
-
To measure a wide range of pressure in an explosive endangered area the range of pressure modules is extended with 8 ATEX compliant models.
-
Product
Infrared Gas Detector
GD10 Series
-
Teledyne Gas & Flame Detection
The GD10 Series has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations.These infrared gas detectors differ from all other models, because they utilize silicon based solid-state infrared sources. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved while providing unparalleled service life and detector stability, thus saving on maintenance and service costs.We offer the longest combined detector and IR source warranty on the market.
-
Product
Infrared Thermometer
DITH 120
-
Infrared Thermometer is also known as laser thermometerInfrared thermometer is a thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.Laser is used to help aim the thermometer or non-contact thermometers or temperature guns, to describe the device's ability to measure temperature from a distance. By knowing the amount of infrared energy emitted by the object and its emissivity, the object's temperature can often be determined. Infrared thermometers are a subset of devices known as "thermal radiation thermometers".The design essentially consists of a lens to focus the infrared thermal radiation on to a detector, which converts the radiant power to an electrical signal that can be displayed in units of temperature after being compensated for ambient temperature. This permits temperature measurement from a distance without contact with the object to be measured. A non-contact infrared thermometer is useful for measuring temperature under circumstances where thermocouples or other probe-type sensors cannot be used or do not produce accurate data for a variety of reasons.
-
Product
Digital Infrared Thermometer
IR-102
-
Shenzhen Calibeur Industries Co., Ltd..
'- Range:-20℃ ~ 330℃;'- Accuracy: < 0°C ±3°C or ±3% of showed value, ≥ 0°C ±2°C or ±2% of showed value '- Distance Spot Ratio: 8:1; '- ℃ / ℉ exchange;'- Laser Targeting Function'- Backlight,LCD Display;'- Weight: 137g'- Power: 1 * 6F22 9V Alkaline battery (not included)