Filter Results By:
Products
Applications
Manufacturers
Blackbody Cavities
-
product
Blackbody Sources
Hyperion R Model 982
The Hyperion R Calibration Bath comprises a blackbody cavity for calibration of infrared thermometers. An important factor is that its operation range includes ambient temperature, which is a difficult radiation point to achieve.
-
product
Blackbody System
IR-140/301
Infrared Systems Development Corp.
Our extended area sources are flat plate emitters with special high emissivity coating providing 0.96 average emissivity. Extended area sources provide large target with high radiant intensity for application where a cavity blackbody is too small.
-
product
Blackbody System
IR-574/301
Infrared Systems Development Corp.
The IR-574 Series blackbody reference sources are designed to provide infrared radiation as an ideal blackbody emitter. The output energy from the 2.25" Cavity closely follows the theoretical maximum energy curve described by Max Planck's equation, and allow users to calibrate, align, and measure infrared devices and phenoma of all types.
-
product
Cavity Stabilized GUNN Oscillators
Available Frequencies: from 40 to 140 GHz Maximum CW power: 200 mWatt Frequency stability: 0.1 MHz/C
-
product
Blackbody Calibrators
Omega offers a diverse portfolio of blackbody calibrators used to calibrate infrared pyrometers. Blackbody calibrators use a high emissivity target plate or target cavity to minimize error.
-
product
High Temperature Blackbody Source
Pegasus R Model 970
Compact High Temperature Source 150C to 1200C E >0.995. The Pegasus R is a compact furnace for calibrating radiation pyrometers.
-
product
Blackbody System
IR-564/301
Infrared Systems Development Corp.
The IR-564 extends the temperature range of the IR-563 to 1200 º C by changing cavity materials to Silicon Carbide and high purity Alumina ceramics, otherwise the two units are virtually identical.
-
product
External Cavity Diode Lasers
ECDLs
High-performance ECDLs and injection-locked optical amplifier.
-
product
UV SHG Cavity Compact Frequency Quadrupling Module
SolsTiS ECD-X-Q
SolsTiS ECD-X Q extends the range of the SolsTiS platform into the deep UV providing unrivalled power and tuning. SolsTiS ECD-X-Q is used in combination with the ECD X doubling cavity (wavelength ranges between 210–250 nm) or the EMM mixing module (wavelength ranges between 250–300 nm).
-
product
Blackbody System
IR-518/301
Infrared Systems Development Corp.
The IR-518 Radiation Source provides an accurate, stable source of infrared radiation of known flux and spectral distribution. It can be used as a standard radiation source for the calibration of other laboratory sources, detectors, or other infrared devices requiring calibration against a standard.
-
product
Blackbodies
Blackbodies are devices that work as near perfect emitters of thermal radiation in range from visible to microwaves. There are many blackbodies available on international market. Inframet specializes in high-tech expensive blackbodies optimized for narrow market of high requirements. All blackbodies offered by Inframet are characterized by special features.
-
product
Microwave Cavity Characterization
Material Sensing & Instrumentation
Microwave cavity characterization complements TDR Dielectric Spectroscopy in low-loss materials, providing high-resolution permittivity and loss data at specific single frequencies. Since measurements do not change significantly with frequency in low-loss materials (Kramer-Kronig relation) cavity measurement at select frequencies provides a full characterization across the RF/microwave range.
-
product
Practical Use Precision Type Comparison Blackbody Furnaces
IR-R6, IR-R7, IR-R8
Practical use precision type comparison blackbody furnaces cover the temperature range of 100 to 3000°C by 3 kinds of blackbody furnace and calibrate radiation thermometers accurately.
-
product
Blackbody System
IR-508/301
Infrared Systems Development Corp.
The IR-508 blackbody reference source is designed to provide infrared radiation as an ideal blackbody emitter. The output energy from the 0.25" cavity closely follows the theoretical maximum energy curve described by Max Planck's equation, and allows users to calibrate, align, and measure infrared devices and phenomena of all types.
-
product
Zero Field Cavity
Zero field cavities generate a zero magnetic field in an air gap. They are mainly used to calibrate hall probes for their zero scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using Zero Field Cavity.
-
product
Blackbody System
IR-2103/301
Infrared Systems Development Corp.
Infrared Systems Development introduces a NEW Low-Cost Thermo-Electrically cooled / Heated blackbody source. The 0.375" Thick solid Copper Emitter plate provides superior uniformity and energy emission. Our Proprietary High Emissivity Black Coating provides >0.95 uniform Emissivity from 0.8 to 30 um.
-
product
Blackbodies & Extended Area Sources
The Infinity Series of blackbody radiation sources and extended area sources combine leading edge technology with features that support the expanding test requirements of the latest high performance sensors. SBIR designs the most stable, uniform, accurate and highly emissive blackbodies available. SBIR now offers VANTABLACK®S-IR as an optional coating, providing the E-O test community an unprecedented flat plate source emisisivty. SBIR continues to offer blackbody systems that provide the test community with unequaled performance, reliability and ease of integration into test systems. Our blackbody family includes six different varieties to choose from. The Infinity line offers four types of precision blackbody systems and our extended area sources offer two additional types of precision blackbodies to support all levels of IR testing.
-
product
UV & Visible SHG Cavity
SolsTiS ECD-X
The external cavity doubler SolsTiS ECD-X is an extension for SolsTiS. It extends the range of output wavelengths via frequency doubling in a resonant cavity with optimised conversion efficiency to generate high power output from 350-525 nm with a suite of crystals and a single optics set. Automatic, stable lock to SolsTiS is achieved with Hansch-Couillard locking. ECD-X automatically follows SolsTiS frequency scans to deliver >40 GHz of mode hope free tuning across the doubled wavelengths.
-
product
Blackbody System
IR-563/301
Infrared Systems Development Corp.
IR-563 is a ideal source for the Near (1-3 um), Mid (3-8) and Far (8-30+ um) infrared bands. The IR-563 has been the industry standard 1000º C blackbody for more than 30 years, and continues to provide excellent service to infrared applications throughout the industry. The IR-564 extends the temperature range of the IR-563 to 1200º C by changing cavity materials to Silicon Carbide and high purity Alumina ceramics, otherwise the two units are virtually identical.
-
product
Dual Blackbody Wide FOV
Dual blackbody, all reflective background IR target projector is used to characterize WFOV IR sensor systems. It features a broadband, 3 to 14 micron range, reflective IR target technology for the most accurate and stable differential targets, controlled background radiance, a 5º FOV with 36º uniform background.
-
product
Blackbody Sources
Gemini R Model 976
The Gemini R comprises a blackbody with which radiation pyrometers (infrared thermometers) can be calibrated. The temperature of the cavity can be set to 0.1C over the temperature range 30C to 550C.
-
product
Coupled Cavity TWTs
Communications & Power Industries
• Frequencies from 2.7 to 37.5 GHz• Peak levels: 500 W to 180 kW• Cooling type: air, liquid, conduction• Depressed or grounded collectors• CW (Continuous Wave) and Pulsed
-
product
Blackbody Calibrators
Omega offers a diverse portfolio of blackbody calibrators used to calibrate infrared pyrometers. Blackbody calibrators use a high emissivity target plate or target cavity to minimize error.
-
product
Ray tracing and Laser Simulation / Cavity Design Software
LasEasy V1.0
LasEasy software is the professional software for simulating and designing solid-state laser cavity, optical amplifier system, and parametric OPO systems. It can also simulate the laser light propagation in both horizontal and vertical (sangital and tangitial) planes.
-
product
Cavity Stabilized IMPATT Oscillators
Available Frequencies: from 26.5 to 140 GHz Maximum CW power: 300 mWatt Frequency stability: from 0.05 to 0.2 MHz/C
-
product
Sodium heat Pipe Blackbody Source
Oberon R Model 426
The Oberon R uses a Sodium heat Pipe to ensure an exceptionally low temperature gradient along the furnace core. It is ideal for the realization of Aluminium, Silver or Copper ITS-90 Fixed Points.
-
product
CN-37 Blackbody
Compact thermal camera reference source. Compatible with all thermography cameras on the market and IEC 80601-2-59 compliant. Available now, ready to ship.