Product
Independent 24-bit Sigma-Delta Type (One for Each Channel)
TR1
-
The TR1 provides 8 channels which can be individually programmed as a Thermocouple (TC) or a Resistance Temperature Detector (RTD) measurement interface. When configured as a TC, the channel can interface with virtually all thermocouple-type NIST temperature ranges. When configured as an RTD, the channel can interface to two, three and four-wire platinum RTD sensor configurations.
-
Product
3-Slot Data Acquisition Mainframe With GPIB, Three 20-Channel Multiplexer Modules, And BenchVue DAQ Software
DAQ973MBX
Mainframe
The DAQ973MBX Best Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe, three 20-channel DAQM901A multiplexer modules, and a BV0006B BenchVue DAQ software with a KeysightCare software support subscription. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2-and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning measures thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance36-month node-lock BV0006B BenchVue DAQ software license with KeysightCare software support subscription
-
Product
REM-11120, 4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O
784750-01
Temperature Input Module
4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O - The REM‑11120 is a temperature input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11120 from a real-time controller such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. The REM‑11120 also has an adjustable filter time for improved measurement quality and optional external cold junction compensation (CJC) or PT100 resistance temperature detector (RTD) measurements.
-
Product
PXI RTD Simulator Module, 24 Channel, PT100
40-263-001
Simulator
The 40-263-001 is a 24-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module 18-Channel PT1000
40-262-002
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
Measurement & Simulation
-
Highland Technology offers a wide array of tools for measurement, simulation, and control. Tachometers, thermocouples, RTDs, precision voltages, current loops, strain gauges, and more can be measured or simulated by Highland's products.
-
Product
3-CH RTD Input Module
ND-6013
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
RTD / PRT Platinum Sensing Resistor Inserts
-
RTD / PRT Platinum Sensing Resistor Inserts - Ceramic Sheathed, Pt100 & Pt1000 Inserts
-
Product
Handheld Economic Process Calibrator
VA701
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This Multifunction calibrator combined voltage. current .resistance .thermocouple temperature .RTD in one device.
-
Product
Dual Relay Trip Amplifier for RTD and Slidewire Sensors
SEM1633
-
The SEM1633 provides an accurate alarm / switching function when used with RTD or Slidewire sensors. Other sensor characteristics or your own 22 point linearization characteristic (for slidewire or linear resistance) can be downloaded into the product enabling you to adapt it exactly to your application.
-
Product
Analog I/O Modules
-
ADAM-5000 AI/O modules offer different voltage and current ranges, thermal coupling, and RTD to fulfill multiple applications.
-
Product
Power Meters andCalibration Cells
-
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
Product
PXI RTD Simulator Module, 12 Channel, PT100
40-263-301
Simulator
The 40-263-301 is a 12-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
Probes
RTD
-
No matter the application, ThermoWorks has a probe for you: penetration probes, immersion probes, air probes, surface probes, wire probes, even specialized probes like griddle probes, burger probes, pipe clamp probes, and probes for medical and lab use. Choose from standard tip, reduced tip, corkscrew tip, alligator clip, or needle probes; different handle types; and straight, coiled, stainless overbraid or even armored cables. Sensor types include type T or type K thermocouples, RTD sensors and our Pro-Series® line of thermistor probes.
-
Product
6U CPCI Multifunction I/O Board
78C1
Multifunction I/O
The 78C1 is a universal 6U cPCI Multifunction I/O Board that eliminates the complexity and size constraints of using multiple, independent, single-function cards. This single slot card has six module positions, allowing developers to achieve a custom configuration with any combination of function modules, such as A/D (10-channels), D/A (10-channels), Discrete I/O (16-channels), TTL I/O (16-channels), Differential Multi-Mode Transceivers (11-channels), RTD (6-channels), Synchro/Resolver (4-channels), LVDT/RVDT (4-channels), and Signal Generator (4-channels).
-
Product
Reference Thermometers
-
Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
Product
Temperature And Humidity Data Loggers
-
These dataloggers are used to monitor and record temperature and/or humidity. Available in either single or multi channel inputs for thermocouple, RTD, thermistor, & infrared temperature sensors.
-
Product
Two-way Wireless Temperature and Humidity Data Logger with LCD
RFRHTemp2000A
-
The RFRHTemp2000A is two-way Wireless temperature and humidity data logger with LCD. Transmits up to 2000' maximum (outdoors unobstructed). Built-in memory also stores data internally. This device is calibrated traceable to N.I.S.T. and is available with a Calibration Certificate. The RFRHTemp2000A is ideal for both industrial or laboratory applications including supply chain storage facilities, incubator monitoring and HVAC studies. Designed with external humidity and RTD based temperature sensors, the device provides a fast response time for both parameters.
-
Product
RTD Measurement for VMEbus
VME390
-
The VME390 features 24 two, three or four wire high-accuracy PT100 measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued.
-
Product
Industrial Temperature Head Sensors
-
A selection of Head Mounted Industrial Temperature Sensors for many applications with RTD / PRT varieties, Hygienic and Heavy Duty probes.
-
Product
Cryostat Calibrators
-
Electronic Development Labs, Inc.
Specialized, low-temperature, passively cooled, or liquid nitrogen-based apparatuses designed to calibrate temperature sensors (RTDs, thermocouples, PRTs) at cryogenic levels.
-
Product
sbRIO-9219, Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module
781027-01
Analog Input Module
Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The sbRIO‑9219 is designed for multipurpose testing. With the sbRIO‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel. Non-enclosed modules are designed for OEM applications.
-
Product
PXI-2720, 8-Bit, 10-Channel PXI Programmable Resistor Module
781985-20
Programmable Resistor Modules
8-Bit, 10-Channel PXI Programmable Resistor Module—The PXI‑2720 is a test module that replicates the behavior of resistance-based inputs and outputs such as potentiometers, resistance temperature detectors (RTDs), voltage dividers, and bridge elements. The PXI‑2720 programmatically controls a series of relays to vary the resistance across each channel of an I/O connector. This function is well suited for simulating environmental conditions in hardware‑in‑the‑loop (HIL) validation. The software provides a simple user interface that accepts inputs in units of temperature or resistance and configures the resistance across each channel.
-
Product
Temperature Transmitter
T4311
-
Transducer is designed for temperature measurement at C or F by means of the externaltemperature probe with RTD Pt1000 sensor.
-
Product
RTD Measurement for PCI
PCI390
-
The PCI390 features six 2-, 3-, or 4-wire high-accuracy RTD measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued. The local DSP (TMS320C203) performs linearization, auto-calibration and alarm-limit checking. Sensor-data is available in °C, °F, K and Ohms. All inputs are optically isolated from the system.
-
Product
sbRIO-9218, Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module
783362-02
Analog Input Module
Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module - The sbRIO‑9218 helps you perform multipurpose testing. With the sbRIO‑9218, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors. You also can use the sbRIO‑9218 to perform quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. You can individually select and perform a different measurement type on each channel. Additionally, the sbRIO‑9218 features 60 VDC analog input isolation. Non-enclosed modules are designed for OEM applications.
-
Product
RTD Calibrators
-
Practical Instrument Electronics, Inc.
PIE has an RTD calibrator to fit your needs from the PIE 510B single type RTD simulator to the advanced troubleshooting capabilities of the PIE 311Plus. Have you had issues in the past where your RTD calibrator wouldn’t work with some of the instruments in your plant? Our RTD calibrators are guaranteed to be compatible with all process RTD inputs including all brands of smart temperature and multivariable transmitters, PLC input cards, DCS systems and multichannel recorders.
-
Product
Signal Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
If you are looking for Signal calibrators that are best in industry, head over to Nagman website immediately. We have a range of signal calibrators, loop calibrators, milliamp calibrators, process meter and more. Depending on the requirement at hand, you can find a signal calibrator that is best suited for your industry. Signal calibrators can be used for calibrating thermocouples, RTD, transmitters, etc. while loop calibrators are used for calibrating controllers, indicators, etc. Nagman’s range of signal calibrators are handy, light weight, portable and durable.
-
Product
PXI RTD Simulator Module, 16 Channel, PT1000
40-263-203
Simulator
The 40-263-203 is a 16-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
8 Channels, RTD Measurement
RT1
-
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.