DOS
-
Product
Low-Profile 16-CH Isolated DI & 16-CH Isolated DO PCI Card
LPCI-7230
Analog Input Module
ADLINK LPCI-7230 is 32-CH isolated input and/or card. It provides a 2,500 C optical isolation protection. Two wide input range of the LPCI-7230 makes it easy to sense the status of external devices. The non-polarity characteristic is suitable for a wide variety of industry applications. The LPCI-7230 devices also feature a wide output range from 5 to 35 V, which is suitable for relay driving and industrial automations applications. The LPCI-7230 also provides two interrupt sources on digital input channels, which are easily user configurable.
-
Product
PXI-6230, 8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Hybrid, Multifunction I/O
779616-01
Multifunction I/O
8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6230 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 5 V TTL/CMOS signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6230 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6230 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
Logger version CTD profiler with optical fast DO sensor
RINKO-Profiler
-
CTD profiler with optical fast DO sensor
-
Product
Digital output version optical fast DO sensor
RINKO II / II D
-
Rinko II is a digital output version with a fast-response optical DO sensor. The instrument can be easily integrated on platforms, because it works with communications by RS-232C or RS-485 and an external power (12 to 24V DC).Rinko IID has not only a temperature sensor but also a depth sensor. Their models can monitor DO in real time, if you have a personal computer and an external power.
-
Product
PXI-6236, 4 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module
779622-01
Multifunction I/O
4 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6236 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 5 V TTL/CMOS signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6236 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6236 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
Dissolved Oxygen (DO) & Temperature Pen
Ultrapen™ PT5
-
*Reliable Repeatable Results*Accurate*Affordable*Easy to Use*Rugged Design*Ensure Product Quality*Reduce Waste*Protect the Environment
-
Product
PXI-6232, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module
779618-01
Multifunction I/O
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6232 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6232 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6232 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
PXI-6233, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module
779620-01
Multifunction I/O
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6233 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6233 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6233 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
Portable optical DO meter
ARO-PR
-
The Portable optical DO meter makes use of the fast-response optical DO sensor RINKO, maintaining its high-speed response performance (99% response < 7sec). The meter probe is equipped with a temperature sensor close to the sensing foil, and the measurements are made by simply inserting the probe into a DO sample bottle (the calibration is carried out using the National Metrology Institute of Japan (NMIJ) certified traceable gases standards). Differently from galvanic electrode sensors, the instrument does not require water sample stirring or fixing reagents, since there is no oxygen consumption. Thus, the required time to estimate dissolved oxygen is considerably reduced. The display unit shows the output instantaneously, and you can check the measured values in real time.
-
Product
PXI-6238, 8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Hybrid, Multifunction I/O
779624-01
Multifunction I/O
8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6238 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6238 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6238 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
PCI-6154, 4 AI (16-Bit, 250 kS/s/ch), 4 AO, 6 DI, 4 DO, PCI Multifunction I/O Device
779340-01
Multifunction I/O
4 AI (16-Bit, 250 kS/s/ch), 4 AO, 6 DI, 4 DO, PCI Multifunction I/O Device - The PCI‑6154 is a simultaneous-sampling, channel-to-channel isolated DAQ device. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. You can combine the channel‑to‑channel isolated analog outputs to generate signals greater than ±10 V (up to ±40 V by combining all four channels). The PCI‑6154 is ideal for a variety of applications including automotive test, industrial monitoring and control, and high-speed continuous data logging. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.