-
Product
RTD Data Logger
-
RTD Data Logger is the most commonly used sensors for measuring temperatures in various industries. These are positive temperature coefficient resistive sensors and Pt100 is the most commonly used type of RTD sensor which has 100 ohm resistance at 0 C. IM2000 series RTD data loggers offer bridge measurement technique to compensate for effect of wire length. In addition logger has facility to program offset so that the measurements are more accurate.
-
Product
PXI RTD Simulator Module, 12 Channel, PT1000
40-263-303
Simulator
The 40-263-303 is a 12-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module, 4 Channel, PT500
40-263-502
Simulator
The 40-263-502 is a 4-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
RTD Measurement for CompactPCI
CPCI390
-
The CPCI390 has a 3U form factor and features six 2-, 3-, or 4-wire high-accuracy RTD measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued. The local DSP (TMS320C203) performs linearization, auto-calibration and alarm limit checking. Sensordata is available in °C, °F, K and Ohm. All inputs are optically isolated from the system.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
4 2/3 Digital Temperature (RTD) Meter (1/32 DIN)
CS3-TR
-
CS3-TR Temperature Indicator has been designed with Pt100 (3 wire) high accuracy measurement.A compact body design for small equipment, laboratory instrument, and others.Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications.
-
Product
PXI RTD Simulator Module, 24 Channel, PT500
40-263-002
Simulator
The 40-263-002 is a 24-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Wireless Precision RTD Based Temperature Data Logger with LCD
RFRTDTemp2000A
-
The RFRTDTemp2000A is an RTD-based, wireless temperature data logger with display. This data logger is ideal for applications that require high accuracy temperature monitoring such as within laboratories, pharmaceutical and biotech industries. The RFRTDTemp2000A accepts 2, 3 or 4 wire 100Ω platinum RTD’s and features a device accuracy of +/-0.5°C.
-
Product
Miniature In Head RTD/ Slidewire Temperature Transmitter
HTR200
-
The HTR200 ‘smart’ transmitter is designed for use with RTD or Slidewire sensors. It is integrated into the MA style head making it ideal for applications where space is restricted
-
Product
PXI RTD Simulator Module, 16 Channel, PT500
40-263-202
Simulator
The 40-263-202 is a 16-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
CT / PT Analyzer
CTPTA-504
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
UDEY ‘CTPTA-504 is a comprehensive CT and PT analyzer. It’s constant voltage and current is highly stable. DSP system controls the constant voltage and current source output and amplitude. This source generates AC of 0-125V and or DC of 0-0.5A current to sample CT. The DSP system besides controlling the sources, also samples data and communicates with the internal computer. Display screen is large LCD with touch pad. The analyzer is highly accurate with high noise immunity and is very user friendly.
-
Product
Thermocouple & RTD Termometers
-
Amprobe thermocouple thermometers give you a professional way to measure, monitor and log temperature. Eight models let you choose the accuracy and feature set you need. For superior accuracy and stability in a process environment, choose an Amprobe RTD thermometer.
-
Product
RTD Thermometers
-
Precision Platinum Temperature Sensor, High Accuracy With 0.01°C Resolution, Automatic Locked Push-pull Connector For Easy Connection, Large Back Light LCD
-
Product
PXI RTD Simulator Module, 8 Channel, PT1000
40-263-403
Simulator
The 40-263-403 is an 8-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
PXI RTD Simulator Module 6-Channel PT100
40-262-101
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
PXI RTD Simulator Module 12 Channel PT100
40-262-201
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
Product
3-Ch RTD Input Module
ADAM-5013
Input/Output Module
Accuracy: ±0.1% or betterEffective resolution: 16-bitInput connections: 2, 3 or 4 wireSampling rate: 10 samples/sec. (total)Isolation voltage: 3000 VDCInput type: PT100 or Ni RTDChannels: 3
-
Product
PXI RTD Simulator Module, 20 Channel, PT1000
40-263-103
Simulator
The 40-263-103 is a 20-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module, 12 Channel, PT500
40-263-302
Simulator
The 40-263-302 is a 12-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module 6-Channel PT1000
40-262-102
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
DH Series PT Browser Tip, 16 GHz BW, 3.5 Vpp Range
DH-PT
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Suitable For RTD Sensors Approved To ATEX And IECEx Standards
TTR200X -
-
The TTR200X is our mid range transmitter for RTD or Slidewire sensors approved to ATEX and IECEx standards. It can accept many different types of RTD sensor such as Pt100, 500, 1000 etc and slidewire sensors up to 100K Ohm
























