Probe Interfaces
Connect ATE instrumentation to interface test adapter.
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-1I35-6
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PXI-8517, 2-Port PXI FlexRay Interface Module
780689-02
FlexRay Interface
2-Port PXI FlexRay Interface Module—The PXI‑8517 is designed for developing FlexRay applications. As part of the NI‑XNET platform, the PXI‑8517 works well in applications requiring real-time, high-speed manipulation of hundreds of FlexRay frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The PXI‑8517 contains two fully functional FlexRay interfaces, allowing an individual ECU to be connected to the interface when other cold-start nodes are not available. You also can use the interfaces individually to connect two separate FlexRay networks while maintaining full performance on each interface.
-
Product
BMP-3 Board Marker Probe
BMP-3
ICT/FCT Probe
Current Rating (Amps): .05Voltage Rating (VDC): 15Recommended Duty Cycle: 1 sec. On (min.), 5 sec. OffTest Center (mil): 1,300Test Center (mm): 33.02Full Travel (mil): 62Full Travel (mm): 1.57Recommended Travel (mil): 50Recommended Travel (mm): 1.27Full Marker Travel (mil): 62Full Marker Travel (mm): 1.57Direction of Rotation: CCWScribed Diameter (mil): 50Scribed Diameter (mm): 1.27Rec. Mounting Hole Size (mil): 610Rec. Mounting Hole Size (mm): 15.50Recommended Drill Size: 39/64 (in) or 15.50 mm
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1P-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1L24-8
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1T24-8-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Interface
RQVME2-1553
Interface
The RQVME2-1553 provides new levels of performance and flexibility for MIL-STD-1553A and B Notice II on the VMEbus. Available in commercial, industrial and conductively cooled versions with one, two or four dual-redundant channels, the RQVME2-1553 includes advanced API (Application Programming Interface) software that reduces application development time.
-
Product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25H79-6.5
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
500 MHz 60 V Common Mode Differential Probe
DL05-HCM
Differential Probe
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
Product
Interface
RCNIC-A2PA3
Interface
The RCNIC platform is a high performance, 3U CompactPCI module (PMC on carrier card) for the AFDX/ARINC 664 protocol. With two independent ports for traffic monitoring, traffic generation, external triggering and analysis, the RCNIC provides high-resolution time-tagging of incoming packets simultaneously with highly accurate traffic generation. An IRIG-B receiver/generator is included for synchronization to an external IRIG-B time source and for synchronization between multiple RCNIC boards.
-
Product
32 Channel Multi-Purpose DIOS/TAP Modules/Interfaces for Spare JT 2148 QuadPOD Transceiver Slot
JT 2149/MPV eMPV
Interface
The JT 2149/MPV and the JT 2149/eMPV are a 32 channel multi purpose DIOS/TAP pod modules/interfaces that can be plugged into any spare JT 2148 QuadPOD transceiver slot. The DIOS channels of these units I/O interface pods enable increased fault coverage and thus improved diagnostic resolution during boundary-scan testing. The principal difference between the two versions is the use of an extended case on the eMPV that allows standard 0.1″ connections to be used to access ths TAP and static IO signals (see tab below)- on the standard /MPV unit these signals are available at the front face 0.05″ connector. The units are fully supported by JTAG Technologies’ development tools. Additional DIOS modules can be serially connected if more parallel access points are required.
-
Product
COM Express Type 7 10GbE SFP+ Network Adapter Card
CEI-2x10G SFP+
Network Interface Controller
- Support up to two 10GbE SFP+ interfaces- Inphi CS4227 inside- COM.0 R3.1 Type 7 compliant- Dedicated for Express-VR7
-
Product
1553 Avionics Interface 3U CPCI Card
QCP-1553 Series
Interface Card
The QCP-1553 module is a rugged, reliable, full featured, Compact PCI module designed to provide a stand-alone, MIL-STD-1553A/B interface for avionics applications. Up to four independent dual redundant MIL-STD-1553 databus streams are supported by the 3U QCP-1553 module. Additionally, the module offers full functional test, simulation, monitoring and databus analyzer functions for MILSTD-1553A/B applications. An onboard IRIG-B time code decoder and generator allows users to accurately synchronize single or multiple QCP-1553 modules to a common time source. The QCP-1553 module is available in dual or full function (RT simulation, monitoring, and bus controller) configurations.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1I-7-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-1I8-6
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Super 3.90 (111.00) - 16.00 (454.00) High Performance Lead Free Probe
LFRE-25A-16
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PCI-8511, 2-Port, Low‑Speed/Fault-Tolerant CAN Interface Device
780682-02
CAN Interface
The PCI‑8511 is a fault-tolerant controller area network (CAN) interface for developing applications with the NI‑XNET driver. The PCI‑8511 excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time for processing complex models and applications.
-
Product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1H-8
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-1A-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PCI-8532, 1-Port, DeviceNet Interface Device
781062-01
Interface
The PCI‑8532 is a high-speed DeviceNet Interface for developing applications with the NI‑Industrial Communications for DeviceNet driver. DeviceNet is based on the controller area network (CAN) physical layer and increases strength and interconnectivity by specifying various parameters, such as the required cable length, connectors, and baud rates. The DeviceNet specifications are managed by OVDA, Inc. You can program the PCI‑8532 to add high-performance master/scanner or slave capabilities to DeviceNet networks.
-
Product
BMP-4 Board Marker Probe
BMP-4
ICT/FCT Probe
Current Rating (Amps): .020Voltage Rating (VDC): 12Recommended Duty Cycle: 2 sec. On (min.), 3 sec. OffTest Center (mil): 1,000Test Center (mm): 25.40Full Travel (mil): 79Full Travel (mm): 2.01Recommended Travel (mil): 50Recommended Travel (mm): 1.27Full Marker Travel (mil): 62Full Marker Travel (mm): 1.57Direction of Rotation: CCWScribed Diameter (mil): 50Scribed Diameter (mm): 1.27Test Center Remark: Ø .398 (10.1) or M10
-
Product
COM Express Type 7 10GBASE-T Network Adapter Card
CEI-2x10GBASE-T
Network Interface Controller
- Support up to two 10GbE BASE-T interfaces- Marvell AQR113C inside- COM.0 R3.1 Type 7 compliant- Dedicated for Express-VR7
-
Product
DER-075 Double-Ended Receptacle
DER-075
ICT/FCT Probe
Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 130Recommended Travel (mm): 3.30Overall Length (mil): 1,710Overall Length (mm): 43.43Rec. Mounting Hole Size (mil): 53Rec. Mounting Hole Size (mm): 1.35Rec. Mounting Hole Remark: 53 to 55 mil / 1.35 to 1.40 mmRecommended Drill Size: #54 or 1.40 mm
-
Product
COM Express Type 7 10GBASE-T Network Adapter Card
10GBASE-T Network Adapter Card
Network Interface Controller
- Supports up to four 10GbE copper interface (10GBASE-T)- Compatible with PICMG COM.0 R3.0 Type 7 modules
-
Product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1P-8
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PXI-8513 , 2-Port, Software-Selectable PXI CAN Interface Module
780688-02
CAN Interface
2-Port, Software-Selectable PXI CAN Interface Module—The PXI‑8513 is a software-selectable Controller Area Network (CAN) interface for developing applications with the NI‑XNET driver. NI‑XNET Software‑Selectable CAN Interfaces offer the best flexibility for CAN development with onboard transceivers for High-Speed/Flexible Data‑rate, Low-Speed/Fault Tolerant Single Wire CAN as well as any external transceiver. The PXI‑8513 excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI‑XNET device-driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts.
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1T-6-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Mini PCI Express
MPCIE-A429
Interface Card
Alta Data Technologies’ MPCIE-A429 Mini PCI Express F1 interface module offers a variety of ARINC-429/575/717 channel configurations with software selectable RX/TX channels, baud rates, bit encoding and word configurations (Start/Sync/Stop length, Parity, bits/word, MSB/LSB). Encode or decode almost any ARINC-429 transceiver compatible signal.
-
Product
CP-059-025 Battery Probes
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 313Overall Length (mm): 7.95





























