Temperature Calibrators
Measure and source/simulate RTDs, thermocouples, Volts, and ohms to test and calibrate temperature sensors and transmitters.
-
Product
Calibration Baths
-
Fluke Calibration temperature baths provide optimal temperature environments for “secondary” or “comparison” temperature calibrations. They offer unsurpassed stability and uniformity, a large working volume, and flexibility for performing thermometer calibration on calibrating a variety of temperature sensors. A world-class temperature controller and 30+ years of experience make these the choice of National Metrology Institutes and calibration laboratories worldwide. Fluke Calibration temperature baths include: compact temperature baths; deep-well temperature baths; standard calibration baths; resistor maintenance baths; ice-point baths; bath / temperature controllers.
-
Product
Radiometric Drone Thermal Camera
FLIR Vue Pro R
-
The Vue Pro R gives drone operators and certified thermographers the power to gather accurate, non-contact temperature measurements from an aerial perspective. Every still image the Vue Pro R saves contains accurate, calibrated temperature data embedded in every pixel, adding even more value to your sUAS operations and services than ever. Vue Pro R adds fully radiometric data-gathering to sUAS applications like building and roof inspections, power grid inspections, infrastructure analysis, precision agriculture, and public safety.
-
Product
Thermo-Hygro-Barometer
C4141-4
-
Audio and optical alarm of measured temperature. Minimum/maximum memory. memory of minimum and maximum temperature included traceable calibration certificate. LCD backlight.With external air temperature-humidity probe on a 4 meters cable. Probe diameter is 18mm, length 135mm. Built-in indoor temperature and air pressure sensors.
-
Product
Handheld Water Quality Meters
LAQUA PH210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers) - 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
Product
Thermometer
C0111
-
Audio and optical alarm of measured temperature. LCD backlight. Minimum/maximum memory. Memory of minimum and maximum temperature included traceable calibration certificate.
-
Product
Hall Effect Probes
-
Magnetic Instrumentation manufactures Hall Effect Probes in a wide range of styles and sizes. Probes are supplied with magnetic, electrical, temperature stability and calibration data for each measurement range.
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
Calibration Cable
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
15-meter (49 feet) Sensor Cable
E1739C
Calibration Cable
The E1739C 15-meter (49 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System. Other cable lengths available: E1739A 5-meter (16 feet), E1739B 10-meter (33 feet) and E1739D 25-meter (82 feet).
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
785259-01
Temperature Input Module
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
Mechanical Calibration Kit
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
Temperature Input Module
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
779592-01
Temperature Input Module
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
Product
Diagonal Measurement Kit
10768A
Mechanical Calibration Kit
The Keysight 10768A Diagonal Measurement Kit is designed for use with the Keysight 5530 Laser Calibration System. It allows linear measurements to be made on the four body diagonals of a machine tool's working volume. These measurements document the machine's capability and quickly perform a complete check of volumetric positioning performance. In addition, long-term drift tests can be performed over hours or days, showing possible effects of temperature on geometry.
-
Product
Calibration Lead Precision Resistor - Single
40-975-009-SL1
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
FD-11614, 16-Channel Temperature Input Device for FieldDAQ
785854-01
Temperature Input Module
The FD-11614 measures up to 16 thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11614 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11614 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11614 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
Product
CalPod Drive Cable, 40 GHz, 2 Meter
85553A
Calibration Cable
This cable provides the bias voltages and control signals for operation of the 40 GHz CalPod modules. This cable is supplied with the 85540/41/42A CalPod modules.
-
Product
FD-11613, 8-Channel Temperature Input Device for FieldDAQ
785640-01
Temperature Input Module
8-Channel Temperature Input Device for FieldDAQ - The FD-11613 measures up to eight thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11613 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11613 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11613 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
10-meter (33 feet) Sensor Cable
E1739B
Calibration Cable
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
Mechanical Calibration Kit
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
Sensor Cable, 5 M
E1739A
Calibration Cable
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
Mechanical Calibration Kit
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
T-Type Thermocouple, 32°F to 500°F Temperature Sensor
745685-T02
Temperature Sensor
T-Type Thermocouple, 32°F to 500°F Temperature Sensor - The T-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure … measurements and predefined scaling coefficients for the T-Type Thermocouple and acquire synchronized temperature data in units of degrees. The T-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.





























