Current Calibrators
An accurate current units of measure to facilitate comparison to and adjustment of instruments.
-
Product
Current Calibrators
-
Used for basic measurements, tests and regulation techniques for setting and verifying test installations and instrumentation.
-
Product
SQUID Electronics
XXF-1
-
It is designed to satisfy the needs of nearly all low-Tc SQUID applications. Additional integrated current sources provide e.g. bias current and calibration pulses for TES applications. These current sources together with an additional switchable feedback path make two-stage SQUID operation very convenient.
-
Product
Three-Phase Electric Power/Energy Calibrator
MC133Ci
-
The MC133Ci model is a compact one-housing three phase electric power/energy calibrator. It can supply the device under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A.
-
Product
Multifunction Calibrator 15 ppm Basic Accuracy
MC142
-
Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.
-
Product
Multi Function Calibrators
-
This range of multi function calibrators are designed for accurately simulating various sensor values such as temperature, voltage and current for calibration purposes.
-
Product
Resistors for Calibration of Current Measuring Systems and Sensors/Transducers
-
ChenYang Technologies GmbH & Co. KG
Is designed and made according to the Standard JB/T8225-1999 for DC resistors used in laboratory and electrical engineering.By using full closed structure and automatictemperature control it ensures resistor good long-term stability and small temperaturecoefficient. This DC resistor is very suitablefor DC current measurement and calibration of current measuring systems and current sensors. The maximal measuring current is 100A with measuring accuracy of ±0.02%
-
Product
Standard CT
6300A
-
The Model 2509 Instrument Current Transformer is a 6300 A ampere CT designed for precision measurement of AC current or for Instrument Current Transformer calibration applications. The CT can be installed on a bus bar or it can be used with a primary conductor consisting of number of turns. The 6300 CT is designed with a tapped primary & a tapped secondary winding, thus providing a large number of ratios over a range of 5 to 6300 amperes.
-
Product
Calibrator, Calibrated, Current, 185 mm, 78 mm, 38 mm, ± (0.25% FS +1 digit), ± (0.5%FS + 1 digit)
72-6694 CAL
-
The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Calibrator, Calibrated w/D & U, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL DU
-
The 72-6694 CAL DU from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
-
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
IEC Standard Burden Sets (Current)
IEC Burden Sets
-
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
Product
Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g
72-6694
-
*Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details
-
Product
High Current Calibrator
MC151
-
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
Product
CALIBRATOR Multi Function Calibrator
MC140
-
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
Product
Voltage And Current Calibrator
-
Precision Mastech Enterprises Co.
A precision instrument designed to generate (source) and measure precise electrical signals.
-
Product
Three-Phase compact Electric Power/Energy
MC133C
-
The Model MC133C is a compact single housed three phase electric power/energy calibrator. It can supply the device under test with precision one phase AC voltage and current with calibrated phase shift along with DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A.
-
Product
Multifunction Voltage and Current Calibrator
MC140i
-
Multifunction calibrator MC140i is ideal for calibration of voltmeters, ammeters, DMMs and panel meters. AC/DC voltage 1uV to 1000V. Current 50uA? to 1000A using test coil. Deviation control along readout. 0.0035% basic dc accuracy. 0.03% basic ac accuracy. Supplied with RS232 interfaces. UKAS/NIST Traceable
-
Product
One Phase Electric Power/Energy Calibrator
MC133
-
The MC133 master unit model is a one phase electric power/energy calibrator. It can supply the device under test with single phase precise voltage and current with calibrated phase shift along with DC voltage and current capability. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A. Simulated electric power can be set independently for each phase. Frequency can be set from 15Hz to 1 kHz with resolution 0.001Hz to 0.01Hz. The MC133 Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20mA or 10V for direct calibration of various types of power transducers and wattmeters.
-
Product
Current Source
M151
-
Clarke-Hess Communications Research
The Model M151 is a stable high current calibrator up to 120 A. Basic accuracy is 0.035 %. It can be controlled viaRS232 or GPIB interface. The Model 151 can function in a simulated amplifier mode to increase the current capabilityof any multifunction calibrator. It is suitable for power meter calibration because it can be synchronized with the inputsignal not only in amplitude but also in frequency and phase. The current terminals are isolated up to 450 Vpk againstcase (protective earth).
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
10-meter (33 feet) Sensor Cable
E1739B
Calibration Cable
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
NI-9265, 4-Channel C Series Current Output Module
779334-01
Current Output Module
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
C Series Voltage And Current Input Module
Current Input Module
The C Series Voltage and Current Input Module features up to 16 input channels with built-in noise rejection. You can use this module to combine the two most common inputs to reduce the overall number of modules you need in your measurement system.The C Series Voltage and Current Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
High Voltage Probe, 100:1, 3.7 KVpk, 500 MHz
10076C
High Current Probe
The Keysight 10076C 3.7 kVpk, 100:1 passive probe gives you the voltage and bandwidth you need for making high-voltage measurements. Its compact design makes it easier to probe today's small power electronics components, and its rugged construction means it can withstand rough handling without breaking.
-
Product
NI-9253, 50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module
785989-02
Current Input Module
50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module - The NI-9253 is an 8-channel analog input module for ComapctDAQ and CompactRIO systems. Each channel provides a ±20 mA input range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9253 has several diagnostic features to ensure your system is operating nominally at all times with open channel detection, power supply detection, and configurable thresholds. The NI-9253 has eight LEDs to indicate the status of each channel and the power supply so that a user in the field can easily validate that the system is operating normally. The NI-9253 also features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
Product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
High Current Probe
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
1 Mm Calibration Kit
85059B
Mechanical Calibration Kit
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
Electronic Calibration Module
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
Calibration Cable
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.