Current Calibrators
An accurate current units of measure to facilitate comparison to and adjustment of instruments.
-
Product
Primary Current Injection Test Set
T 3000
-
T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers
-
Product
Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/P -
-
SEM1605/P - Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
-
Product
Automatic Calibration Module
ACM4520
-
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Lightning Current Generator
-
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
Product
Time, Current, And Resistance Meter
-
AllWin Instrument Science and Technology Co., Ltd.
1. Time, current and resistance can be displayed simultaneously2. Out put current:5~30A. Ground resistance range: 50~600 mohm
-
Product
AC/DC High Sensitivity Clamp-On Current Probe
N7026A
Oscilloscope Probe
The Keysight N7026A is a 150 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features wide and flat bandwidth (DC-150 MHz), lower noise (<250 µArms), and wide input range (up to continuous 30 Arms or non-continuous 40 Apeak). This enables you to measure down to 1 mA/div, giving you a much more accurate view of your low-level signals.
-
Product
PXI Analog Output / Current Loop Simulators
-
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
Product
Primary Current Injection Kits
-
During installation,testing,especially if the protective gear is connected to the power line via a current transformer it is advisable to use our Primary Injection Test Set. Keeping this in mind a wide range of Primary Current Injection Test Sets are being manufactured by "NMC”.
-
Product
Fully Integrated Eddy Current Instrument
MIZ-28
-
MIZ-28 delivers more technology and exceptional performance for high-speed and high-efficiency inspection of heat exchanger tubing. It comes equipped with industry leading data management features with more on-board data storage and easy file transfer.
-
Product
Machine Calibration and Optimisation
-
Renishaw's laser interferometer and ballbar measurement systems assess, monitor and improve the static and dynamic performance of machine tools, co-ordinate measuring machines (CMMs) and other position-critical motion systems.
-
Product
High AC Current Capacitors
-
HK Film Capacitors offer a selection of High AC Current Capacitors ( continuous duty) with Temperature up to +105C
-
Product
L.V. Current Transformers
-
ENTES LV Current Transformers are measuring transformers which transform the primary current by a specified ratio to its secondary side with a phase difference of 0 degrees. They provide isolation of the relays and measuring devices from the HV side of the network.
-
Product
Hall Effect DC Current Sensor
CYHCT-L20K
-
ChenYang Technologies GmbH & Co. KG
The sensor CYHCT-L20K is based on open loop principle and designed with a high galvanic isolationbetween primary conductor and secondary circuit. It can be used for measurement of DC current, DCpulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
Calibration & Repair Services for Instruments in Process Control
-
Meeting customer needs is our number one priority. Hastings Instruments offers free technical support as well as personalized one-on-one customer service through a diverse organization of field Customer Service Representatives and Distributors. We have more than 50 field Customer Service Representatives that are situated to provide local support throughout the world.Additionally, reaching our Customer Service Department is only a toll-free number away (USA) and is available for your convenience. Faxing or E-mailing your question first will assure that it is reviewed before you speak to a Customer Service Representative. Also, following the steps listed in our trouble shooting guides (included in each product instruction manual) may help direct you to the appropriate department before you pick up the phone to call.
-
Product
12-Channel VME Current Loop/Process Control I/O Module
V220
-
The V220 is ideal for driving and sensing transducers in computer or PLC-based control systems. It can also be used to simulate complex industrial processes to control systems under development and certification.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Quad 3-Channel, 2-Pole
40-514-103
Multiplexer Module
The 40-514-103 (PXI) and 42-514-103 (PXIe) are low density multiplexers in quad 3-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Dry Block Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
Dry Block calibrators are used for the most accurate calibration of temperature devices. Ideal for quick / fast Site Calibration of RTDs / Bi Metal Thermometers, Temperature Switches / Indicators etc. in Industrial & Marine Applications. Dry block calibrators can be used for a very wide range of temperature from – 100°C to over 1500°C. Nagman hosts a range of calibrators that are Stable, portable, heavy duty and budget friendly.
-
Product
Frequency to Current Converter
DAT4540R
-
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Single 12-Channel, 2-Pole
42-514-105
Multiplexer Module
The 40-514-105 (PXI) and 42-514-105 (PXIe) are low density multiplexers in single 12-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Thermistors (Temperature Sensors, Current Control)
-
The resistance value changes in response to temperature changes in the ambient environment or due to heat generated by applied voltage or current.
-
Product
Thermometer Calibration
-
In addition to the vast array of Thermometers that Comark has an offer, We also offer a range of devices to assist you with Thermometer Calibration.
-
Product
Standard Voltage 37 Pin D-Type Cables - Calibration Cables for Pickering
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 37-pin D-type calibration port connector.
-
Product
NIST Calibration for D610-A
D610-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
AC/DC Leakage Current Tester
228
-
Test for dangerous leakage current with the Simpson Model 228, designed to meet the latest UL, IEC, and ANSI specifications. The 228 detects both AC and DC leakage current and simulates human response at three different levels -- reaction, let-go, and burn hazard. Each Model 228 comes with test leads with alligator clips, manual, and batteries.
-
Product
Automated Leakage Current Tester
LINECHEK® II Series
-
Our LINECHEK II Leakage Current Tester is designed for medical device manufacturers. With a feature set built around maximizing the efficiency of the Leakage Current test, LINECHEK II satisfies medical application requirements demanding up to 40 Amps of continuous line current. Use it on the bench or in a rack, from the front panel or via a PC interface to ensure your medical device is ready for global deployment.
-
Product
Mini AC Leakage Current Clamp Tester (CE)
M-140
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*40mmφCT window and ultra compact size.*Least affection from the external magnetic field.*Wide current measurements.(AC0.01mA-300A)
-
Product
Wide Range Flexible Current Probe
EFX6000
-
The EFX6000 is a flexible AC current clamp utilizing the Rogowski principle. It can be used to measure currents from 1 amp to 6000 Amps in 2 auto-ranges, over a wide frequency range to 10kHz. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas, around large conductors and where access to confined or tight spaces is a problem. It requires no batteries or external power supply.
-
Product
Multi-Cal Pressure Calibrator
MC
-
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.





























