Data Acquisition Systems
sense, log and store information. Also known as: DAS
See Also: Data Acquisition, PCI Data Acquisition, DAQ
-
Product
Single 16x8 1-Pole High-Density PXI Matrix Module
40-520-203
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
NI-9231, 8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module
783610-01
Sound and Vibration
8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module - The NI-9231 is a high-density sound and vibration module that can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. It can perform the high dynamic range measurements necessary for modern measurement microphones and accelerometers and features simultaneous sampling. The NI-9231 incorporates both a TEDS input path and 2 mA of IEPE signal excitation source that can be turned on and off, removing the need for external sensor power and reducing the complexity of the data acquisition system.
-
Product
Analog Multiplexer Board
104-AIM-32
-
The 104-AIM-32 is an analog signal multiplexer conforming to the PC/104 standard. The card will multiplex and condition 16 differential or 32 single-ended analog signals before passing them to an analog-to-digital converter card like the 104-AIO12-8. A system may comprise one to seven of these cards in tandem with one 104-AIO12-8 A/D converter board. The 104-AIM-32 card may be used as part of a large data acquisition system. The 104-AIM-32A Kit consists of one 104-AIM-32 and one 12-bit 8-input A/D board.
-
Product
PXI 2A Multiplexer, 16-Bank, 8-Channel 1-Pole
40-614-001
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI High Density Multiplexer, 4-Bank, 40-Channel, 1-Pole
Multiplexer Module
The 40-615A-007 is a 2-bank, 80-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
PXI Multiplexer, Dual 32-Channel, 1-Pole
40-630A-022-D/32/1
Multiplexer Module
The 40-630A-022-D/32/1 is a dual 32-channel, 1-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Operational Modal Testing
-
EDM Modal Operational Modal Testing (OMA Testing) includes a dedicated test setup and operation process flow using ambient vibration data. Using a large channel count data acquisition system (e.g., Spider- 80X or Spider-80Xi), the excitation method provides a much higher efficiency and accuracy for FRF measurements while minimizing local stresses on the test article.
-
Product
PXI Ultra High Density 64x2 2-Pole Matrix
40-533B-032
Matrix Switch Module
The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.
-
Product
PXI High Density Multiplexer, 20-Bank, 4-Channel, 2-Pole
40-615A-002
Multiplexer Module
The 40-615A-002 is a 20-bank, 4-channel, 2-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pinconnector.
-
Product
PXI 2 Banks of 40 Channel 2 Pole MUX
40-615-022-2/40/2
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
PCI High Density Screened MUX 10 Ch 8 Pole
50-670-021-S-10/8
Multiplexer Module
The 50-670 series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Data Acquisition System
DAQ973A
Data Acquisition System
Get the next-generation data acquisition (DAQ) system with a three-slot mainframe and your choice of nine plug-in modules. Interface with the DAQ using Keysight BenchVue DAQ software or use the intuitive graphical front panel with task-oriented, self-guiding menus.
-
Product
Multi-Channel Data Acquisition System
PI-3105
-
This highly flexible system is designed to test a wide variety of imaging devices, from low-noise astronomy and medical devices, to military and machine-vision devices with GB/sec data rates.
-
Product
PXI 2 Amp Multiplexer, Single 16-Channel, 4-Pole
40-635A-003
Multiplexer Module
The 40-635A-003 is a single 16-channel, 4-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
Data Loggers
-
Data loggers are an essential component in data acquisition systems. They can scan a wide variety of measurement sensors, perform any programmed calculations, convert the data to other units of measurement, and store the data in memory. Data loggers can also transmit the data for analysis, sharing, and reporting, as well as control external devices.
-
Product
PXI High Density Multiplexer, 1-Bank, 160-Channel, 1-Pole
40-615A-011
Multiplexer Module
The 40-615A-011 is a 1-bank, 160-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
PXI Very High Density Mux 5 Ch 32 Pole
40-670A-022-5/32
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI 2A Multiplexer, 1-Bank, 8-Channel 16-Pole
40-614-019
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXIe Digitizer: 500 MSa/s, 14 bit, 200 MHz
M3102A
Digitizer
The M3102A PXIe digitizer is ideal for general purpose digitizer automated test requirements. It offers high channel density with an advanced data acquisition systems (DAQ). The optional real-time sequencing, inter-module synchronization, and graphical FPGA programming software tools expand its capability to enable a number of solutions including angle of arrival (AoA), baseband electronics designs, wireless device manufacturing and multi-channel coherent signal acquisition.
-
Product
PXI High Density Multiplexer, 1-Bank, 64-Channel, 1-Pole
40-610A-012
Multiplexer Module
The 40-610A-012 is a 1-bank, 64-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI MUX 2 Bank, 32 Channel Screened 1 Pole
40-610-021-S-2/32/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI 2A Multiplexer, 1-Bank, 32-Channel 4-Pole
40-614-017
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
SIRIUS Waterproof
-
SIRIUS Waterproof - Rugged and Modular Data Acquisition SystemExtremely rugged (IP67 degree of protection) and fully isolated rugged data acquisition system for the most demanding testing in harsh environments. High-precision, high-dynamic, and high-bandwidth for all types of analog signals from IEPE to strain gages.
-
Product
PXI MUX 2 Banks of 32 Channel 1 Pole
40-610-021-2/32/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI Very High Density Multiplexer, 49-Channel, 4-Pole
40-675A-002-49/4
Multiplexer Module
The 40-675A-002-49/4 is a 49-channel, 4-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Product
PXI 6U PXI High Density Matrix, EMR 132x8
45-542-001
Matrix Switch Module
The 6U PXIMatrix Module 45-542 is a very high density electro-mechanical relay matrix available in 132x8 format with 1 pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. The matrix is constructed using high reliability 2A electro-mechanical relays, offering >10e8 operations (under low power loads) to give maximum switching confidence with long life and stable contact resistance.
-
Product
Multifunctional Data Acquisition Systems
MS1201
-
This system used for multi-purpose applications such as data acquisition and Automatic Test Equipment. ATE Computer has ISA Bus based eleven slots with inbuilt power supply. Micro Processor board or USB Controller is used to drive the back plane.
-
Product
Consultancy Services
-
CellCare Technologies are experts in all types of standby battery servicing, specialising in automated monitoring, data acquisition systems, on-site battery management and maintenance, together with fault diagnosis and performance prediction. Our services also include product application and consultancy, plus training seminars on standby battery maintenance. Health & Safety courses to ensure compliance with COSHH regulations are also available.
-
Product
PXI High Density Mux 10 Channel 8 Pole
40-670A-021-10/8
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI 2A Multiplexer, 8-Bank, 16-Channel 1-Pole
40-614-003
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.


























