Transformer
transfers of electricity from one circuit to another by electro-magnetic induction.
See Also: Transformer Testers, Power Distribution, Coil
-
Product
Burn Down Transformer
ATG 6000
-
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level
-
Product
Differential Transformer Type Extensometers
DT Series
-
ISO Class 1 Compliant Differential Transformer Type Extensometers The ISO 6892-1 standard for tensile testing of metallic materials prescribes Class 1 or higher extensometers, and JIS Z2241 prescribes Class 2 or higher extensometers when measuring withstanding pressure. The DT series includes Class 1 compliant differential transformer type extensometers, which can be used to implement test methods compliant with metal tensile test standards.
-
Product
Transformer Test Equipment
-
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
Product
Distribution Transformer Tester
DOC-2000™
-
The DOC-2000™ is a test instrument designed for distribution networks transformers up to 167KVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The DOC-2000™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
Product
Transformer Turns Ratio Meter
TTRM 302
-
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
Product
2KVA Scaler Transformer
T-1005
-
The Titan Series T-1005 Scaler Transformer is used to conveniently scale the standard OV to 130V/260V full scale AC Power Source/Frequency Converter output to 76 different full scale voltages and currents. It is also used to join and scale the power from multiple Titan series AC Power Sources/Frequency Converters into a single output. It has a conservative continuous power rating of 2KVA and excellent voltage regulation.
-
Product
Transformer Turns Ratio Meter
TTRM 301
-
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
Product
Transformer Winding Resistance Meters
TWA Advanced Series
-
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
Product
Transformer Ratio Meters / TRM-101
TRM-101
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Produces the 3-ph or 2-ph standard power with stable voltage and phase. Fully automatic: No manual balancing
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
Transformer Ratio Meter
TRM 1000
-
AJIT Transformer Ratio Meters are the most modern turn's radio meters widely used to test the turn's ratio of high voltage windings, to low voltage windings, of Transformer. These meters are accurate, compact & light in weight.
-
Product
Transformer Winding Resistance Meter
XWRM-10
-
The Motwane Manufacturing Company
The Motwane make XWRM-10 is a dual channel 10A rated, Transformer Winding Resistance Meter designed and developed aftere xtensive research on challenges and requirements of testing of various Transformer winding resistance. The instrument has One Current channel and two Resistance Channels. The instrument provides a large open circuit voltage of 42Volts, for fast charging of the highly inductive windings of transformers, to provide stable resistance values in minimum time. The XWRM-10 is intended to replace complex bridge set up with a single compact instrumentThe XWRM-10 is based on 4-wire measurement methodto measure low resistance accurately. The instrument iswell protected against inductive kickbacks offered by theinductive windings and gives stable reading on varioustypes of transformers.
-
Product
Instrument Transformer & Switchgear Testing
-
Our stationary and mobile instrument transformer test systems are used to test current and voltage instrument transformers. Among other things, accuracy testing, demagnetization and insulation testing are possible.
-
Product
Power Transformer Testing
-
Weshine Electric Manufacturing Co., Ltd
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime.
-
Product
20 Amp Current Transformer Burden Test Set
1044A
-
Due to overwhelming demand, TESCO is pleased to re-introduce the 1044A 20 Amp Current Transformer Burden Test Set. This light weight, hand held unit is a simple and inexpensive means whereby a current transformer installation may be quickly checked for many sources of trouble. The 1044A provides utilities a less expensive and more traditional option for checking larger services for potential meter circuit related issues.
-
Product
Transformer Turn Ratio Meter
-
A specialized, highly accurate diagnostic instrument used to measure the ratio of primary to secondary winding turns in transformers.
-
Product
True Online UPS Systems with Inbuilt Isolation Transformer
-
Our software and connectivity devices incorporate all the features you need to proactively manage your systems, from basic monitoring and shutdown to predictive analysis and power management. Aplab Integration Services offer complete solutions tailored for the specific requirements of Defense Services, Telecom and Commercial markets.
-
Product
Transformer Analyzer
505
-
The UTEC 505 Transformer Analyzer is designed for testing current transformers (CT) and potential transformers (PT) without interruption of the customer’s service. This instrument measures CT admittance, CT ratio, CT primary-to-secondary phase angle and the voltage, current and phase angle of the service. With the ‘Burden CT/PT Option’, it determines the CT secondary burden capability, the regulation of the PT and its secondary burden capability and provides for CT core demagnetization.
-
Product
Transformer Bench Tester
KVBT
-
KV Hipot Power Test Equipment Co.,Ltd
Transformer Test System is applied for ex-work and maintenance detecting on various transformers.
-
Product
AC Test Transformer Products
-
Shanghai Guantu Technology Co., Ltd.
Manufacturing scope:Output voltage: 0~200kVOutput capacity: 0~20kVATechnical features of AC test transformer:Light weight; adopting oil-filled and air-filled structures reduces weight by 20% year-on-yearStatic noise; uniform electric field design and special fastening structure, no discharge and no mechanical noise at rated outputHorizontal iron core structure reduces the center of gravity of the equipment to a low pointMulti-flange combination with high structural strengthKey parts are cushioned with advanced elastic materialThe control box has complete protection functions and strong overload capacity
-
Product
Test Set For Instrument Transformer
-
This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.
-
Product
Multiple Gas Transformer DGA
MULTITRANS
-
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
Product
Split Core Current Transformer
-
Beijing GFUVE Electronics Co.,Ltd.
Have a "split" in the core that allows the CTs to open and be placed around the conductor without having to disconnect the conductor or disrupt the wiring.
-
Product
Split type AC Current Transformer
CTS-600
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*5A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy to install by metal fitting.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
Transformer Heat Run Tester
-
1. Suitable for all transformers below 240MVA heat run test and winding resistance testing.2. Printing heat run data automatically.3. With double power supply, can test high voltage side and low voltage side simultaneously and test any operation respectively.4. With anti breakage protection function of inductive test items.
-
Product
Harmonic Mitigation Transformer
-
A specialized three-phase transformer designed to reduce harmonic distortion and voltage distortion caused by non-linear loads (e.g., computers, VFDs) in electrical distribution systems.
-
Product
Transformer Performance Tester
JYM
-
JYM insulation resistance tester is used for on-site insulation resistance measurement. The instrument has built-in positive and negative bipolar high-voltage power supplies, with large output power and strong load capacity. It is suitable for insulation resistance measurement of samples with large capacitance, such as power transformers and cables.
-
Product
Integrated Transformer Test Van
XD90
-
Hangzhou Xihu Electronic Institute
The XD90 integrated modular power system testing vehicle provides an integrated yet flexible solution of preforming a wide selection of normal and specialty tests on power equipment. Designed with the effectiveness and efficiency of power testing in mind, this platform achieves the goal of “integration of functions” instead of just a “combination of instruments”. Not only it provides an abundant means of power testing, but with optimized device placement, operational convenience, and safety factor.
-
Product
GDGS Transformer Power Factor And Tan Delta Tester
-
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
GDGS Transformer Power Factor and Tan Delta Tester





























