Product
PXI 22-Channel 2A Fault Insert Switches
40-202-001
Fault Insertion Unit
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
Product
PXIe-4145, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit
782435-01
Source Measure Unit
PXIe, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit - The PXIe-4145 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4145 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4145 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Source Measurement Unit
SMU8
Source Measure Unit
The SMU8 offers high voltage SMU in a compact, 3U PXI / USB form factor. The SMU8 supports 0V to +4V 0.5A or 0V to +12V 25.6mA with FVMI, FVMV, FIMV, FIMI modes. 8 channel can be ganged to support high current driving.
-
Product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-212
Fault Insertion Unit
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
High Precision Source Measure Unit (SMU) - Hybrid Compatible PXI, 100ks/S Programming/Measurement Speed
52400 series
Source Measure Unit
Hybrid Compatible PXIFour quadrant operationHigh source/measurement resolution (multiple ranges)Low output noiseHigh programming/measurement speed (100k s/S) & slew rateOptional measurement logDIO bitsOutput profiling by hardware sequencerProgrammable output resistanceFloating & Guarding output16 Control Bandwidth SelectionMaster / Slave operationDriver with LabView/LabWindows & C/C# APISoftpanel GUI
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Source Measure Units and LCR Meters
Source Measure Unit
Source Measure Units are high-precision, high-accuracy DC instruments that can both source and simultaneously measure voltage and current. Additionally, LCR Meters can measure the inductance, capacitance, and resistance (LCR) of electronic equipment.
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
Source Measure Unit
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-193A-002-HI
Fault Insertion Unit
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
PXIe Source/Measure Unit, 15 MSa/s, 1 PA, 60 V, 3.5 A DC/10.5 A Pulse
M9602A
Source Measure Unit
The Keysight M9602A is a PXIe SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
Precision Source / Measure Unit, 1 CH, 1 PA Resolution, 21 V, 1.5 A
B2901BL
Source Measure Unit
The Keysight B2901BL precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXI 5A Fault Insertion Switch 20-Chan 1-Bus
40-198-001
Fault Insertion Unit
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXIe-4141, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit
781743-01
Source Measure Unit
PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit - The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Autonomous Driving AI Decision Making ECU
ADM-AL30
Electronic Control Unit
ADM-AL30 is dedicated to Autonomous Driving Applications. Powered by Intel® 12th Gen Core i9/i7 CPU and the NVIDIA RTX 4000 SFF Ada GPU, this AI computing platform can process huge amounts of data and make crucial decisions for autonomous vehicles. Equipped with 2 x 10G Base-T and 8 x 1G Base-T1 automotive ethernet ports, as well as 8 x CAN FD and 4 x CAN 2.0 interfaces, it seamlessly integrates into any automotive ecosystem. Plus, its ISO 16750-2 and ISO 7637-2 ensure reliability and safety under the most demanding conditions.
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
Fault Insertion Unit
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
Fault Insertion Unit
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
3U OpenVPX Sensor Interface Unit - SIU36
SIU36
Sensor Interface Unit
The SIU36 is a highly configurable rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, communications, Ethernet switching and processing. The SIU36 leverages NAI’s 3U boards to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
Product
Integrated AI-ADAS ECU And Cameras For Large Commercial Vehicle
ADM-TJ30
Electronic Control Unit
The integrated AI-ADAS ECU is connected to 8 cameras and powered by the vision-AI algorithm. It can detect and classify different kinds of vehicles/ pedestrians/ two-wheeler riders/ lane marking and other objects to perform multiple ADAS functions.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-02
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers
-
Product
Source Measure Units
NGU
Source Measure Unit
Thanks to their extremely high accuracy and fast load recovery time, the R&S®NGU source measure units (SMU) are perfect for challenging applications. A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The instruments’ short recovery times enable them to handle fast load changes that occur, for example, when mobile communications devices switch from sleep mode to transmit mode. With high speed data acquisition, every detail is detected down to 2 μs resolution.
-
Product
Precision Source / Measure Unit (2 Ch, 10 FA)
B2912B
Source Measure Unit
The Keysight B2912B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
Fault Insertion Unit
42-205-008 (PXIe) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXI Source Measure Unit
Source Measure Unit
PXI Source Measure Units (SMUs) combine high-precision source and measure capability with features designed to reduce test time and increase flexibility. These features include high channel density for building parallel SMU test systems, deterministic hardware sequencing for minimizing software overhead, and high-speed update and sample rates for quickly changing setpoints and acquiring data. Additionally, the flexible sampling rate and streaming capability of PXI SMUs allows you to use the instrument as a digitizer to capture transient behavior, and the digital control loop gives you the ability to adjust the transient response of the instrument. The ability to change the transient behavior of the SMU, called SourceAdapt, reduces SMU settling time and minimizes overshoot and oscillations, even with highly capacitive loads.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 1-Bus
40-199-001
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
High-Density Precision SMU (10 PA, 30 V)
PZ2131A
Source Measure Unit
The Keysight PZ2131A is a high-channel density precision source / measure unit (SMU) having 5 channels per module and saving space for a wide range of applications requiring numerous precision power supplies. The narrow-pulse function and fast Digitizer Mode allow the PZ2131A to expand the conventional static DC measurements to emerging dynamic measurements. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2131A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2131A suitable for noise-sensitive applications such as quantum computing as well.
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
Fault Insertion Unit
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
Fault Insertion Unit
The 40-205-008 (PXI) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXIe-4143, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit
782431-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit - The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4143 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4143 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
PXI/PXIe Source Measure Unit Family
PXS(e)840x
Source Measure Unit
The PXS840x PXI SMU family is a high-speed, 4-quadrant source measure unit. Carry out measurements directly on the DUT with the integrated CMU and VMU.