Sound Calibration
assure sound measurement accuracy.
See Also: Sound Calibrators, Acoustic Calibration, Sound, Microphone Calibration
-
product
(94dB & 114dB)Sound Calibrator
AWA6221A
Hangzhou Aihua Instruments Co., Ltd.
*Comply with IEC 60942 class 1*Pocket size, portable unit *Frequency 1000 Hz, give independence of weighting*Sound pressure independent of microphone equivalent volume
-
product
Sound Level Assessment System
05NK002
Ideally equipped for carrying out Noise at Work risk assessments, as well as the majority of environmental survey work the Risk Assessment System comes with a choice of Class 1 or Class 2 logging sound meter, calibrator, case and PC download software.
-
product
Class 2 Sound Level Calibrator
SPC70
The SPC70 is a Class 2 sound level calibrator suitable for periodic testing of sound level meters and verifying their accuracy before and after readings, in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB. The output is accurate to 0.5dB with low levels of harmonic distortion. The SPC70 is compatible with the Martindale SP79 Class 2 Sound Level Meter and other meters with microphones up to 25mm.
-
product
Acoustic Calibrator
CAL150
The Larson Davis CAL150 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment
-
product
Class 1 Sound Level Calibrator
HD2020
The HD2020 sound level calibrator is a portable, battery operated sound source, suitable for sound level meters (portable and laboratory) and acoustic stations.
-
product
Class 2 Sound Level Meter
SP79
The SP79 is a Class 2 sound level meter for on-site measurements in accordance with Noise at Work legislation in industrial and office environments. Featuring A and C frequency weighting and fast and slow time weighting, the compact design can be handheld, or mounted on a tripod for longer term monitoring of Min / Max values. Detailed recording and analysis can be made using the AC and DC outputs. The SP79 complies with BS EN 61672-1:2003 and is supplied with a detachable windshield and hard carry case. The large high contrast display includes both digital reading and analogue bar graph. An optional Class 2 sound level calibrator is available to verify accuracy before and after readings in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB.
-
product
Hydrophone
RESON TC4013
The TC4013 offers a usable frequency range of 1Hz to 170kHz and a high sensitivity relative to its size. It further-more provides uniform omnidirectional sensitivities in both horizontal and vertical planes up to high frequencies.The TC4013 is an excellent transducer for making absolute sound measurements and calibrations within a broad frequency range. It can also be applied as an omnidirectional reference projector.The overall characteristics makes TC4013 extremely applicable for laboratory as well as industrial uses.
-
product
PC based USB Real Time Analyzer
1) Measurement microphone and its accessories (a windshield and a microphone clip)2) XLR-to-USB Converter3) USB cable (1.5 m) 4) CD (contains the copy-protected Multi-Instrument Software) 5) USB hardkey (contains a Multi-Instrument Standard License)6) Audio Test CD (contains a list of audio test tones and noises) (AudioTestCD.zip or AudioTestCD.rar)7) 1/8” TRS cable (1.8m) 8) Black Soft Pouch Case 9) Individual Sound Level Calibration Data 10) Individual Microphone Calibration Data (only provided in RTA-168B)11) A small microphone stand
-
product
Sound Level Meter, 94 dB, 114 dB, 0 °C, 50 °C
72-2680
The 72-2680 from Tenma is a sound level calibrator. It is a useful tool to calibrate the sound level meter. It has two heavy duty or alkaline type, DC 9V batteries 006P, MN1604 (PP3).
-
product
Noise Meters
Here you will find a full range with an industrial standard noise meter / sound meter to suit every requirement. With the portable noise meter you can carry out measurements quickly to gain control of a situation or to set the sound meter to take timed measurements. The noise meter is important for all industries, especially by using it as a mobile noise meter which is able to assess office stress levels or street noise levels. Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10 pm in excess of what local laws permit. A noise meter / sound meter will help here.We can assess which noise meter or sound meter you require in relation to the issue you have and the relating laws (requirements regarding a sound meter and a sound meter’s usage vary depending on the country). We also have noise meter microphone extension cords, tripods, sound meter calibrators and calibration certificates for most noise meter models.
-
product
PXIe-4463, 51.2 kS/s, 2-Output PXI Sound and Vibration Module
783086-01
The PXIe‑4463 offers high dynamic range and THD+N for audio, acoustic, and vibration applications. It provides the high precision and dynamic range necessary for the most stringent audio generation requirements in a modular form … factor. The PXIe‑4463 contains two 24-bit digital‑to‑analog converters to allow for fully differential simultaneous generation. Complete with three gain ranges, the PXIe‑4463 can generate current with programmable, per channel output configurations. The two timing engines allow you to perform multisample-rate applications on a single module and independently start and stop channels on a single module.
-
product
PXIe-4463, 51.2 kS/s, 2-Output PXI Sound and Vibration Module
783086-02
51.2 kS/s, 2-Output PXI Sound and Vibration Module - The PXIe‑4463 offers high dynamic range and THD+N for audio, acoustic, and vibration applications. It provides the high precision and dynamic range necessary for the most stringent audio generation requirements in a modular form factor. The PXIe‑4463 contains two 24-bit digital‑to‑analog converters to allow for fully differential simultaneous generation. Complete with three gain ranges, the PXIe‑4463 can generate current with programmable, per channel output configurations. The two timing engines allow you to perform multisample-rate applications on a single module and independently start and stop channels on a single module.
-
product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-03
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
782000-01
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
product
NI-9250, 2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module
783827-01
2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module - The NI‑9250 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers and microphones. The NI‑9250 is also compatible with smart TEDS sensors. The NI‑9250 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
product
Sound Level Calibrators
PeakTech Prüf- und Messtechnik GmbH
For sound level measurements in extreme conditions, at high altitudes or high demands on the accuracy of the measurement results, sound level meters should be checked prior to the measurement with a sound level calibrator. Also for calibration and verification of microphones in audio technology, you need a sound level calibrator, which is designed to produce several sound pressure levels at a fixed frequency characteristic. This calibrator has two switchable calibration steps.
-
product
Calibration Kit YAV90MMU
YAVMMUCK
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
product
Precision Sound Level Calibrator
CAL200
The Larson Davis CAL200 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (f)
85563A
Combines an open, short, and load standard in a compact unit that is easy to handle and lightweight
-
product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
product
C Series Sound And Vibration Input Module
The C Series Sound and Vibration Input Module incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. The modules are compatible with smart TEDS sensors.The C Series Sound and Vibration Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-01
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
85033E Standard Mechanical Calibration Kit, DC to 9 GHz