Voltage Calibrators
An accurate voltage units of measure to facilitate comparison to and adjustment of instruments.
See Also: Voltage Sensors
-
Product
CalPod Drive Cable, 40 GHz, 2 Meter
85553A
Calibration Cable
This cable provides the bias voltages and control signals for operation of the 40 GHz CalPod modules. This cable is supplied with the 85540/41/42A CalPod modules.
-
Product
FD-11605, 8-Channel, ±60 V Voltage Input Device for FieldDAQ
786469-01
Voltage Input Module
The FD-11605 can measure up to eight channels with a voltage input range of ±60 V. It features 24-bit resolution with simultaneous sample rates up to 100 kS/s. The FD-11605 offers channel-to-channel isolation, which eliminates noise from ground loops and protects instrumentation circuitry from high-transient voltages of up to 1000 V. The FD-11605 has an ingress protection rating of IP65/IP67 (dust-tight and water-resistant),can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11605 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11605 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11605 is ideal for test cell and outdoor environments.
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-01
Voltage Input Module
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module
785503-01
Voltage Output Module
1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
780180-01
Voltage Input Module
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Product
10-meter (33 feet) Sensor Cable
E1739B
Calibration Cable
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
Mechanical Calibration Kit
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
NI-9215, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783739-01
Voltage Input Module
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
Product
NI-9269, 100 kS/s/ch Simultaneous, ±10 V, Isolated, 4-Channel C Series Voltage Output Module
781098-01
Voltage Output Module
100 kS/s/ch Simultaneous, ±10 V, Isolated, 4-Channel C Series Voltage Output Module - The NI‑9269 is a channel‑to‑channel isolated analog output module. The NI‑9269 adds channel‑to‑channel isolation for increased safety and improved signal quality. Channel‑to‑channel isolation is commonly needed for applications that have multiple electrical systems, such as automotive tests, or industrial applications that are subjected to increased noise and often contain multiple ground planes.
-
Product
Sensor Cable, 5 M
E1739A
Calibration Cable
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
Mechanical Calibration Kit
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779014-01
Voltage Input Module
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
Mechanical Calibration Kit
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
NI-9228 , ±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783861-02
Voltage Input Module
±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9228 performs differential analog input. With channel-to-channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9228 is simultaneous sampling with two options for filtering: a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783311-01
Voltage Input Module
±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.
-
Product
NI-9223, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
781398-01
Voltage Input Module
±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9223 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9223: either four, 2‑position screw terminal connectors or four BNC connectors.
-
Product
sbRIO-9220, Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module
787814-01
Voltage Input Module
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The sbRIO‑9220 helps you perform differential analog input. The sbRIO‑9220 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and … noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9209, ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
783729-01
Voltage Input Module
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
Product
NI-9239, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
779593-01
Voltage Input Module
±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.
-
Product
AC-Powered, AC Voltage Monitor, Adjustable
VMA
Voltage Monitor
NAI’s VMA is a field-adjustable, AC-Powered, AC Voltage Monitor used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits.High and low voltage limits, and "pick-up" and "drop-out" time delay are field-adjustable. The VMA voltage monitor is ideally suited for rugged defense and industrial applications.
-
Product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
783732-01
Voltage Input Module
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
Product
NI-9209 , ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
785042-01
Voltage Input Module
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
Product
1 Mm Calibration Kit
85059B
Mechanical Calibration Kit
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
sbRIO-9222, Non-Enclosed, ±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
785479-01
Voltage Input Module
Non-Enclosed, ±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9222 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The sbRIO‑9222 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the sbRIO‑9222: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
Mechanical Calibration Kit
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
Mechanical Calibration Kit
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.





























