DVB-T2
Digital Video Broadcasting – Second Generation Terrestrial
-
product
Software / Downloads
Pratt & Whitney Measurement Systems, Inc.
Powerful and resourceful, Pratt & Whitney's GageCal Software sets a new standard for user-friendly calibration and part measuring. By controlling the operation and facilitating data collection, GageCal increases total measurement productivity. GageCal is included with the following product lines: Labmaster Universal Model 175, 1000M, 1000A, BM175, BM1000M, BM1000A, Labmicrometer Model 900, 1600, External Supermicrometer Model PC, Universal Supermicrometer Model 501, 504. GageCal is an optional add-on for the External Supermicrometer Model C and Digital Measuring Machines.
-
product
Active Switching Rectifiers, 2 KW, P/N 6016C
- Active Switching Rectifier, 2 KW, P/N 6016C- Input Range: 9 VAC to 35 VAC, 3 PH- Frequency Range: DC to 10 kHz- DC output: 13.5 VDC, 70 Amps without any heatsink (Test #1)- DC output: 13.5 VDC, 150 Amps with heatsink (Test #2)- Dimensions: 8″W x 8″L x 3″H or similar- AC to DC and DC to DC applications- Generates less heat as power MOSFET Switching is used- The output voltage is the same as the input voltage
-
product
19" Rackmount Drawer with Keylock, Unshielded, 8.75"H x 30"D
DR-081930-K
Unshielded drawers are constructed of 20 ga. CRS and are furnished with ball bearing chassis slides to provide smooth operation. Available for 19" and 24" rackmount in 20", 24" and 30" depths, with or without a keylock
-
product
RTD Data Logger
RTD Data Logger is the most commonly used sensors for measuring temperatures in various industries. These are positive temperature coefficient resistive sensors and Pt100 is the most commonly used type of RTD sensor which has 100 ohm resistance at 0 C. IM2000 series RTD data loggers offer bridge measurement technique to compensate for effect of wire length. In addition logger has facility to program offset so that the measurements are more accurate.
-
product
MEMS Fiber Optical Switch at Single Mode 1315nm Type-A with LC/PC Connector
SUN-MS-1x8
Guilin GLsun Science and Tech Group Co., LTD
Fiber Configurations 1x8 MEMS Fiber Type SM, 9/125 umTest Wavelength 1310/1550 nm Operating Voltage 2.5VSwitch Type Non-latching Fiber Length 0.5m±5cmConnector TTL/UART Tube Type 900 umOperating Temperature -5°C~ +70°C Storge Temperature -40°C ~ +85°C
-
product
GN Range Broadband Power Amplifiers 100 KHZ - 200 MHZ
GN Series
Class A solid stateBroadband (instantaneous single band): 100 kHz 200 MHzTypical output power : 500 W CWLinear output power (1 dB compression) guaranted with harmonics <-20dBc:P1dB > 450 W and H < -20 dBc up to 100 MHz andP1dB > 180 W and H < -20 dBc from 100 MHz to 200Air cooling: self contained fansCan operate in full mismatch conditions without damageReliable, efficient and robust19" Rack3 years standard warranty
-
product
Intelligent Interface Card
IIB-1553-VXI-4C
The IIB-1553-VXI-4C is an intelligent interface card which provides 4 independent channels for full MIL-STD-1553 test, simulation and bus analysis functions on the VXI bus. All 1553A, 1553B, McAir and STANAG 3838 variants are supported. Each independent channel may be operated as a concurrent Bus Controller (BC) and up to 31 Remote Terminals (RT) with a windowed Bus Monitor (BM), or as a stand-alone Chronological Bus Monitor (CBM) with comprehensive multi-level triggering capability. Full error injection capability is provided in BC and RT modes, with full error detection in BC, RT, BM and CBM modes. Each channel provides a variable amplitude dual redundant 1553 interface, with 2 Mbytes of dual ported RAM. The board is supplied with C drivers in source code and Windows menu driven software as standard.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-02
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
C Series Voltage Output Module
The C Series Voltage Output Module helps you update analog output models that feature overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. This module includes up to 16 channels. Some models include a channel-to-earth ground double isolation barrier for safety and noise immunity as well as improved signal quality, and some higher density models conserve chassis space, which leaves room for other measurement types.The C Series Voltage Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
Microprobe Thermometer
BAT-12
The BAT-12 laboratory digital thermometer is Physitemp's most popular and best selling instrument due to its versatility, quality construction and low cost.The BAT-12 has 0.1°C resolution and super accuracy of 0.1°C ±1 digit between 0-50°C, 0.1°C ± 1 digit over full range.The temperature range is -100 to 200°C. The BAT-12 provides fast readings, usually within 2-5 seconds depending on the temperature probe in use.
-
product
12 Pulse Diode Bridge Rectifiers Inside Fiberglass Plenums, P/N 5872C4-2
- 12 Pulse Diode Bridge Rectifier, P/N 5872C4-2- Each diode is rated for 60 Amps, 1800 Volts peak- Dimensions: 50″L x 40″W x 20″H approximately- Four 10″ fans are used for coolingFour 10″ fans will force cool from the bottom of the Plenum. 12 diode assemblies (each diode consists of nine diodes in series are integrated together inside the Plenum). The output is rated for 3000 VDC, 80 Amps.
-
product
AC Reference Generators
SR23
Computer Conversions Corporation
The SR23 Series are miniature, low cost AC reference generators designed to supply 26 or 115 volt excitation (2-115VAC) to synchros or resolvers in military and industrial control applications. They accept +/-15V DC or +/-12V DC power inputs and provide up to 5VA of transformer isolated output power. These converters are packaged in PC card mounting modules 2.6”x3.1”x1”H.
-
product
Temperature & Humidity Meters
Shenzhen Everbest Machinery Industry Co.,Ltd.
Function: temperatureRange: -20 to 60°C/-4 to 140°FResolution: 0.1°C/°FAccuracy: ±0.5°C/0.9°FFunction: humidityRange: 0 to 100% RHResolution: 0.1% RHAccuracy: ±3% RH
-
product
Group3 Hall probe
The Group3 Hall probe produces an analog voltage as its output signal, corrected for temperature effects and non-linearities, producing a signal accurate to within 0.05%, from -1 to +1 T, over 10 to 50 deg C. Group3 can offer different field and temperature ranges, and custom probe dimensions.
-
product
1310/1490/1550 Nm DFB-LD For Fiberoptic Communications
RV2X6376A Series of directly modulated laser (DML) diodes deliver 25 Gbps x four wavelengths as the light source in 100 Gbps optical transceivers that enable high-speed communications inside 4.9G and 5G LTE base stations, and between data center routers and servers. The RV2X6376A Series are the industry’s first industrial-temperature (-40°C to 95°C) DML diodes that support full 25 Gbps speed (per individual laser) without cooling.
-
product
IR Calibration Instruments
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
product
Web Sensor
T3511
Web Sensor with relative humidity and temperature probe. The device is supplied with T+RH probe on the cable. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Cable Assembly, 50-Pin D-Type, Male to Female, 2m HV, Exit Away From Pin 1
40-970-050-2m-MF-HV
50-Pin D-Type HV Cable assemblies are constructed from 24 AWG Tinned Copper Wire with PTFE Type C insulation. The connector assemblies can be secured to the mating part by a screwlock. The 50-Pin Female connector options of this product can be directly mated to a corresponding Pickering Interfaces switching product.
-
product
Paramagnetic Oxygen Analyzer
Model T802
The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T802 comes with the NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
AC/DC Power Supply 60 W
TR100M180
AC/DC power supply with 100 W from Cincon | input ranges 90 - 264 VAC | output 18 V | operates in temperature from -20 to +80 °C | provides 2 MOPP
-
product
500W to 1500W - Single Output
LZSA Series
*Five year warranty*-40°C to +71°C Operation*MIL-STD-810E Vibration / Shock*Input transient protected*UL508, SEMI F47, Factory Mutual (Cl 1, Div 2)*Rugged design with conformal coating*Superior thermal design
-
product
High Temperature Diametral Extensometers (1000 C)
Model 3580
Jinan Testing Equipment IE Corporation
This model is for diametral strain measurement with furnace and induction heating systems. Quartz rods and water-cooling allow the unit to be used for high temperature testing of metals, ceramics and composites. With induction heating, this model often can be used without water-cooling. When used in furnaces, the extensometer is often mounted directly to the furnace side cut-out. Optional load frame mounting brackets are available for supporting the extensometer in cases where furnace mounting is not possible. These optional mounts are used with induction heating or furnace systems. The Model 3580 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
sbRIO-9236, Non-Enclosed, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module
781580-01
Non-Enclosed, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The sbRIO‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The sbRIO‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. Non-enclosed modules are designed for OEM applications.
-
product
Code Coverage Branch Monitor
CCBM
Verified Systems International GMBH
The Code Coverage Branch Monitor (CCBM) is a set of utilities that allow instrumentation of C source code for the purpose of branch coverage measurement. This encompasses operations for code instrumentation, removal of this instrumentation, retrieval of coverage information, merging coverage information, and displaying this information with reference to the (original) source code.
-
product
ARINC 429 Test And Simulation PMC Module
PMC-429
*4, 8, 16 or 32 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*PXI interrupts, star trigger, and PXI clock*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Sorting according to SDI field*VXI Plug & Play driver including soft front panel*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
product
Gauge Type T Thermocouple Wire
W-TW-44TEF
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
product
Digital Hardness tester
THL270
Pen type Leeb hardness tester Converts to all common hardness scales (HL.HV,HB,HRC,HRB,HRA,HS). The machine also include interface to connect with impact device C, DC, G, D+15, DL
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T80
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
CompactPCI 4 Slot 2U
2U, 19″ Rackmount system with up to two hot removable CPCI 3U Power Supplies, three Powerful Fans and CompactPCI Backplane. The system support 6U cards Front and Rear. Additional three fans are available for optimal Front and RTM cooling solution. The Backplane is compliant with PICMG 2.0 R3.0 with 64bit 66MHz and supports boards with hot swap capability PICMG 2.1 R2.0. All five CompactPCI connectors (J1-J5) are available on the backplane. The system slot is located on the lower-slot. A backplane supporting PICMG 2.16 & H.110 are available on request.
-
product
Reverberation Chambers
Over the past several decades, RCs have been enjoying growing popularity as a promising facility for the characterization of wireless devices and for EMC testing. The RC (Reverberation Chamber) measurement method exhibits much competitive superiority over the AC (Anechoic Chamber) method and TEM Cell method, such as low cost, enhanced test repeatability, a more realistic test environment, and easily achieved high-field environment. The application of the RC for performing EMC testing was first proposed by H. A. Mendes in 1968. In the recent IEC 61000-4-21 standard, the importance of EMC testing using RCs as an alternative measurement technique has been recognized.