Filter Results By:
Products
Applications
Manufacturers
Integrating Spheres
Uniformly scatter or diffuse light rays.
See Also: Goniophotometers, Spectroradiometers
-
product
Integrating Spheres
Artifex Engineering GmbH & Co. KG
We offer integrating spheres made from a special polymer suitable for the wavelength range 250nm – 2.5 µm. For longer wavelengths in the range 700nm – 20 µm, a gold coating on a rough, metallic surface is used. Since lasers in this spectral range are usually also high power, we use solid copper as a thermally conductive substrate material. By choosing the size of the integrating sphere, the overall sensitivity of the system can be adjusted. In addition, the detector is independent of inhomogeneities in power density and polarization. The detector is also independent of the incidence location and angle of the laser radiation.
-
product
*High Speed, Multifunctional Integrating Spheres
Multifunctional integrating spheres enable simultaneous measurement of multiple laser parameters including:*Power*Pulse Characteristics*Spectrum
-
product
Integrating Spheres - Luminous Flux Measurement For LEDs And Lamps
Konica Minolta Sensing Americas, Inc
One of the most important tests in light measurement is the assessment of the total radiant power or luminous flux of light sources using integrating spheres. An integrating sphere’s inside surface is coated with a diffusely reflecting material which guarantees complete integration and homogenization of the emitted radiation. The integrated light is then measured at the detector port.
-
product
Integrating Spheres For UV
Konica Minolta Sensing Americas, Inc
Instrument Systems offers complete measurement solutions for UV-A, -B and -C radiation starting from 200 nm. The operation of the well-proven Instrument Systems spectroradiometers, e.g. CAS series, with integrating spheres made from PTFE facilitate high sensitivity measurements of UV radiant flux.
-
product
General Purpose Integrating Spheres
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
product
Integrating Spheres & Absolute Flux Integrators
Photometric Solutions International Pty Ltd
PSI’s LF series integrating sphere photometers are widely regarded as excellent quality, robust equipment for industrial or laboratory applications.
-
product
Integrating Sphere Systems
An optical device for various purposes such as. measuring the radiant flux (optical power) from a laser diode, light-emitting diode (LED) or bulb.
-
product
Integrating Sphere Solutions
An integrating sphere is a light collector which takes advantage of physical geometry to homogenize any radiation being emitted inside by relying on a high-reflectance coating material. Depending on the wavelength range the end user using a sphere with, different coatings have different advantages based on the application.
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
product
Spectrophotometer & Integrating Sphere Test System
LPCE-1
This Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry.
-
product
UV-VIS-NIR Spectrophotometer
UV-3600i Plus
UV-3600i Plus, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples. LabSolutions UV-Vis is a next-generation Shimadzu UV control software pursuing efficiency of analysis. LabSolutions UV-Vis software with easy-to-use is included as standard.
-
product
UV-VIS Spectrophotometer
UV-i Selection
UV-3600i Plus, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples.
-
product
Precision Kelvin Holders
MH-4 Series
Integrating Spheres are essential tools for photometricresearch laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary.
-
product
Constant Temperature Integrating Sphere
IS-*MT
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Integrating Sphere FT-NIR Spectrometer
QuasIR 3000™
The QuasIR™ 3000 was designed from the ground up to offer the industry a new kind of NIR analysis solution – a solution that brings together the portability required to move NIR analysis closer to point-of-need, combined with unmatched spectroscopic performance for the fastest and most accurate results.
-
product
Integration Spheres
Offers a wide range of integration spheres (0.25m to 3 m diameter) and spectrometer options, application-specific modules as well.
-
product
Integrating Spheres
All our spheres can be coupled to our high performance spectroradiometer systems for UV-visible-IR spectral power distribution measurements yielding full colour information including colour rendering indices, chromaticity co-ordinates, colour temperature, etc. Alternatively precision photometric detectors can be fitted for direct total lumen output measurements.
-
product
Integrating Sphere Coating
SP-80
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. A good internal coating is essential forintegrating spheres. It is a special water based BariumSulphate (BaSO ) white reflective paint particularly suitablefor internal coating of Integrating Spheres. It offers an almost constant reflectance in the range of 380 nm to 780 nm (visible wavelength range).
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12 tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp be tested up and down in the sphere. • Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option). • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is 0.5×0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C (Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m). • Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request
-
product
Visible Light Source/Integrating Sphere
The Infinity VSX Series Integrating Sphere systems are ultra uniform, highly accurate broadband light sources.
-
product
New Design 3m Electric Integrating Sphere
IS-3.0MA
It has all functions of IS-*MA Integrating Sphere with Holder Base.• Lisun engineers add the infrared anti-pinch device (the video please come to the “video” tab) and the cross laser positioning device in the integrating sphere.• Please refer to article The New Design 3m Electric Integrating Sphere for more information.
-
product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Conversion Kit for Kelvin Holders
KC-4
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary
-
product
High Power Optical Head With Integrating Sphere
81628C
The 81628C High-Power Optical Head features an integrated sphere that enables it to handle power levels up to +40 dBm (with heat sink), across 800 nm to 1700 nm wavelength range. It provides the highest accuracy at high power within the family.
-
product
Integrating Sphere
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
UDT-Series Integrating Sphere Systems
Gamma Scientific offers a variety of pre-configured integrating sphere systems for use in conjunction with the UDT line of optical meters, with both 25 mm and 150 mm diameters.
-
product
Integrating Spheres
IS-*M
• Diameter: IS-0.3M (φ0.3m)、IS-0.5M (φ0.5m)、IS-1.0M (φ1.0m)、IS-1.5M (φ1.5m)、IS-1.75M (φ1.75m)、IS-2.0M (φ2.0m). Other sizes can be designed according to the customer’s request. • The painting of integrating spheres is according to CIE Pub.No.84 (1989) • Material: Pure barium soleplate (BaSO4) • BaSO4 coating: ρ(λ)≥0.96 (450nm~800nm) and ρ(λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectanceρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in lighting holder position: The vertical is for E40, E27 and so on. The horizontal is for T5/T8/T12 tubes. The side assistant opening is for lighting fixtures • Auxiliary lamp position has been built-in. Auxiliary lamp and Auxiliary lamp device are optional • Power cable and socket has been build-in, it is convenient to power the testing lamp • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • The traditional integrating sphere is assembled by several pieces, Lisun Group developed A Molding Technology to produce the integrating sphere. A molding integrating sphere will be more round and the test results will be more accurate than the traditional integrating sphere
-
product
Integrating Spheres
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
product
Standard Light Source
SLS-50W
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.