Filter Results By:
Products
Applications
Manufacturers
Shunts
An Instrument Shunt is a resistor connected in parallel with a measuring device to move the current range beyond a particular value for which the instrument is capable of measuring directly.
See Also: Current Shunts
-
product
Phase Meter Current Shunts
610 and 650
Clarke-Hess Communications Research
The Model 610 and 650 Current Shunts are specifically designed to operate with the Model 6000A Precision Phase Meter. These shunts are frequency tuned to have negligible phase shift (less than 5m) at 50/60Hz making them ideal for line frequency applications. They can also be idealized for other frequencies as specified by the user. Consult factory for details.
-
product
High-Voltage Isolation Amplifier
Knick Elektronische Messgeräte GmbH & Co. KG.
Measurement of DC or AC voltages up to () 3600 V and of large DC currents to about () 20 kA with shunt resistor or directly in the device to () 5A DC and AC. Variants with calibrated range selection.
-
product
Software
Solar Cells/ Photovoltaic Devices
Materials Development Corporation
MDC offers a comprehensive array of current-voltage, capacitance-voltage, and resistivity measurements to characterize solar cells and PV devices. CSM/Win systems and software can help to fine tune your process for maximum efficiency. Critical values such as series and shunt resistances, maximum power point (both actual and theoretical), and fill factor are automatically determined.
-
product
High Power Precision Shunt Resistor
HPS
*Up to 250W on heat sink*Max. current limit 387AExcellent long term stability & short term stability*Low temperature coefficient of resistance (TCR)*High current sensing & reference restores in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
product
Repeated Charge Discharge Test Set
The IS 13341 : 1992 has laid down the requirements for Ageing Test, Self-Healing Test and Destruction Test on Shunt Capacitors of the self healing type for AC Power Systems. The Ageing Test is to be performed at a specified voltage of 1.25 times the rated voltage for 750 hours. The test is to be followed with a repeated discharge cycle test which involves charging of the capacitor to a DC voltage and discharge of the same through an Inductance. Sivananda Electronics has developed this equipment for the benefit of capacitor manufacturers, for the first time in India.
-
product
CAN Sensor/ Interface
Current
Reach Technologies’ CAN Current Sensors sense and digitize conductor current for collection via CAN. The module is ideal for conveniently adding current data to a distributed CAN network. The CAN Current Sensor is configurable via J1939 or CANopen stacks, and are available in Hall Effect and shunt variants.
-
product
High Power Shunt Resistors
CS227
The CS227 is a metal foil, SOT227 resistor designed to give a high current capability. The metal foil element is situated on an insulated heatsink composed of plated copper. This assembly is then mounted into a durable plastic housing and sealed with high temperature epoxy.
-
product
Shunt Voltage References
Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.
-
product
Shunt Reactors
ENTES Shunt Reactors are high quality devices which are designed to meet the inductive load demands.
-
product
Standard Resistor Oil Bath
9400
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
product
Series Voltage References
Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.
-
product
Voltage References
Maxim offers an industry-leading portfolio of shunt and series voltage reference ICs. We were the first to develop a series reference in a 3-pin SC70 and in chip-scale packaging. Our hundreds of voltage references include high-accuracy, low-power, low-noise, and automotive-grade products.
-
product
Differential Sensor, Wide Dynamic Range, 100 MHz
CX1105A
The CX1105A ultra-low noise differential sensor is a dedicated accessory for the CX3300 series and enables dynamic current measurements from 1 μA to 100 A under up to 100 MHz bandwidth with existing shunt resistors on your test board.
-
product
ABex Current Sense Module for Six Channel UUT Supply Monitoring
ABex TM-406 Current Sense
The ABex TM-406 is a six-channel shunt current measurement extension. It’s designed to work in combination with the Konrad ABex TM-501 and PXI-501.Each of the six shunt current measurement units have a passive measurement shunt, an overcurrent protection, a sense bridge relay and the possibility to route the quiescence current to an ABex measurement device TM-501 with PXI-501.In addition, the ABex TM-406 features 8 isolated digital outputs (IDOs), and 12 measurement inputs, which can be routed to the analog bus.
-
product
AC and DC Current or Voltage Transducers
VT7 AND VT8 Series
The Model VT7 Series dc voltage transducer produces an output which is directly proportional to the input from dc to 10kHz. It functions as a millivolt dc shunt or a high voltage isolator to 1000V
-
product
6000 Series Analog I/O Modules
Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.
-
product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2A
The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
product
Shunt Resistor
RSR
Power converters and current measurement instruments. Large current shunt resistor for ampere-meters, designed for standard current measurement of electric equipment. Easy current measurement is performed by attaching to current bus bar directly and connecting to ampere-meter through flexible wires.
-
product
Multi-Channel Digital Power Meters
66203/66204
Chroma Systems Solutions, Inc.
Voltage Range :15/30/60/150/300/600 VrmsCurrent Range :0.005/0.02/0.05/0.2/0.5/2/5/20 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bits Analog/Digital convertersHalf rack size, 4 input modules design (66204)Support different wiring configuration power measurement (1P2W/1P3W/3P3W/3P4W)Support external shunt and CT for higher current measurement application5 mA minimum current range & 0.1mW power resolutionMeets ENERGY STAR / IEC 62301 /ErP measurement requirementsAccumulated energy methods for unstable power measurementUser-define criteria provides automatic PASS/FAIL indicationsDual current shunt design provides high accuracy over a wide current rangeTHD and user-specify order distortion measurementInrush current and energy measurementVoltage/ Current harmonics measurement up to 50 orders
-
product
Midi Logger
GL240
Its compact size contains an isolated input system which ensures that signals are not corrupted by inputs to other channels, thus eliminating wiring concerns. The GL240s multi-type inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature/humidity and voltage. power ground allowing off-ground measurements using shunts, as well as powered or grounded thermocouples.
-
product
AC Current Shunts
AC Current Shunts feature low uncertainty (high accuracy), low temperature coefficients and excellent stability. These shunts are purely resistive with extremely small values of reactance. The 7340 shunts may be used over a wide frequency range from DC to 100 kHz and are optimized for use with thermal converters.
-
product
L Terminal Shunt Resistor
LT
LT shunts are highly accurate manganin resistance D.C. shunts. These shunts are designed for standard current measurement of electric equipment.
-
product
Life Cyclic Durability Testing
Environment Associates can provide everything you need for cyclic durability testing and performance fixturing. Services include mechanical cycling to a position or load, fatigue cycling to a fixed load, rotational torque cycling, and simple push/pull cycling. EA can design your fixture with electro-dynamic, air, or hydraulic assistance to mechanically move your part. All of our fixtures can be manufactured to withstand a wide range of temperature, humidity and vibration inputs. If required, forces can be monitored electronically, using a wide variety of inputs (i.e. strain gages, load cells, rotational transducers, thermocouples, shunts, and more). EA can create holding and check fixtures to perform “pre” and “post” evaluation for dimensional issues that may occur during testing. EA can provide fixtures for single tests run internally for EA test labs and can manufacture fixtures to be purchased directly by the customer for their internal use.
-
product
Signal Conditioner
DMA2
Din rail mountable with user selectable outputs of +/-10V, +/-5V or 4-20 mA. 10-28VDC powered suitable for battery or automotive use. Features 1000 Hz bandwidth and push-button shunt calibration.
-
product
Current Sensing Resistors: ACQ-200
TCS
These components are four-terminal. bus-bar, metal strip current shunts. Assembled using electron beam welding. These units can handle 15W of continuous power and a maximum current of 350A 90.1mohm). Also they can absorb a high pulse power rating and have very low inductance. They also feature excellent long term stability, less than 100ppm/C TCR, and have excellent frequency characteristics.
-
product
Working Standard Shunts
CSW
CSW shunts are rated to 100 % continuous current with no loss of accuracy. They are largely immune from connection errors common to many shunts. All CSW shunts include ISO17025 accredited calibration through full current range.
-
product
PXIe-4330, 25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module
781346-01
25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4330 is a simultaneous input module that provides integrated data acquisition and signal conditioning for bridge-based sensors. The PXIe‑4330 includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4330 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4330 provides remote sensing, internal bridge completion, and shunt calibration options per channel.
-
product
DC Electronic Loads
Keysight DC electronic loads provide you with the flexibility to test a wide range of applications from power-supply test to simulation of high-intensity discharge (HID) headlamps. The 16-bit voltage, current and power-measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.
-
product
Precision Current Shunt
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.