PCB Piezotronics, Inc.
A manufacturer of piezoelectric quartz sensors, accelerometers, and associated electronics for the measurement of dynamic pressure, force, and vibration.
- 800-828-8840
716-684-0001 - 716-684-0987
- info@pcb.com
- 3425 Walden Avenue
Depew, NY 14043-2495
United States of America
-
Product
Precision Condenser Microphone
377C01
-
Performance:Nominal Microphone Diameter:1/4"Open Circuit Sensitivity 2.0 Open Circuit Sensitivity (3 dB)-54 dB re 1 V/PaFrequency Range Inherent Noise<35 Temperature Coefficient of Sensitivity (+14 to +122FHousing Material: Stainless Alloy
-
Product
ICP Electret Surface Microphone
130B40
-
Low-profile surface pressure microphone and preamp, prepolarized
-
Product
Damped MEMS High-G Shock Accelerometers
-
Damped MEMS high-amplitude shock accelerometers represent state-of-the-art industry technology for miniature, high amplitude, DC response acceleration sensors. This series is capable of measuring long duration transient motion, as well as responding to and surviving extremely fast rise times, typical of a high-g shock event as found in explosive, gun and impact testing. Both packaged and OEM configurations are offered, to fulfill a variety of installation requirements.
-
Product
Miniature Piezoelectric Accelerometers
-
Structured with highly sensitive piezoceramic sensing elements, miniature Ceramic Shear ICP® Accelerometers have an excellent signal-to-noise ratio, high measurement resolution, and are ideal for conducting low-level vibration measurements. Due to their inherent higher sensitivity, a ceramic ICP® accelerometer can be assembled with a smaller mass than comparable quartz units, resulting in a sensor that is lighter in weight, has a higher frequency response, and has a lower noise floor. To further reduce the mass of the sensors, all ceramic shear accelerometers are housed in either tough, lightweight, laser-welded, hermetically sealed, titanium or aluminum housings. By minimizing the mass of the sensor, mass loading effects are reduced, which maximizes the accuracy of the data obtained.
-
Product
High Sensitivity ICP® Accelerometers
-
High sensitivity ICP® accelerometers are specifically designed to enable the detection of ultra-low-level, low-frequency vibrations associated with very large structures, foundations, and earth tremors. These sensors typically possess exceptional measurement resolution as the result of its comparatively larger size, which furnishes a stronger output signal and a lower noise floor. All units are hermetically sealed in a titanium or stainless steel housing. Models that include a 2-pin, military style connector provide the added benefit of being electrically case isolated for superior RF and EMI protection.
-
Product
Pressure Sensors For Blast Testing
-
Pressure sensors with quartz, ceramic and tourmaline sensing elements are used for a wide variety of shock wave, blast and explosive testing. All of these applications require high frequency response and durability, ability to drive long cables and operate in adverse environments.
-
Product
General Purpose Quartz Force Sensors
-
General purpose force sensors are offered in either stud or axial mounted configurations. They are internally pre-loaded and can be used for dynamic compression, tension, and impact force measurements. Tapped mounting holes on both ends of the radial connector style support link, platform, integrated link, and free-standing installations. The axial mounted type offers protection of the electrical connector and sensor cable from potential damage during drop testing and in free-standing installations. Supplied impact caps facilitate impact and drop force measurements.
-
Product
Quartz Charge Force Rings
-
Ring-style sensor configurations measure dynamic compression. Tension measurements are also possible if the unit has been installed with proper pre-load.
-
Product
ICP Electret Array Microphone
130A23
-
Nominal Microphone Diameter: 1/4" Frequency Response Characteristic (at 0 incidence)Free-FieldInherent Noise (A Weighted)<30 dB(A) re 20 Pa<30 dB(A) re 20 Pa Dynamic Range (High)150Environmental Temperature Range ( Temperature Effect on Output (-10 to +50 C)<0.7 dB<0.7 dB[2] Influence of Axial Vibration Excitation Voltage 18 to 30 VDC18 to 30 VDC
-
Product
Fatigue Rated Low Profile Cells
-
Fatigue rated load cells are specifically designed for component durability and fatigue test machines where highly cyclical loading is present. These rugged load cells are extremely resistant to extraneous bending and side loading forces. They are used for material testing, component life cycle testing and structural testing. All fatigue rated load cells are guaranteed against fatigue failure for 100 million fully reversed cycles.
-
Product
Torque Transducers
-
The technology behind our torque sensors are strain gages. These gages are arranged into a Wheatstone Bridge circuit, which converts the physical, mechanical force into an electrical signal that can be filtered, displayed, and recorded for further processing. This very accurate radiometric electrical signal is proportional to the applied mechanical force.
-
Product
Pressure Transducers
-
An electromechanical device designed to measure pressure with a high degree of accuracy.
-
Product
Accelerometers
353B15
-
Sensitivity: (10 %);10 mV/g 1.02 mV/(m/s) Measurement Range:500 g pk 4905 m/s pk Frequency Range:(5 %)1 to 10000 Hz1 to 10000 Hz Frequency Range:(10 %)0.7 to 18000 Hz 0.7 to 18000 Hz Frequency Range: (3 dB)0.35 to 30000 Hz0.35 to 30000 Hz Resonant Frequency:70 kHz,70 kHz Broadband Resolution (1)0.005 g rms0.05 m/s rmsNon-Linearity:1 %1 % Transverse Sensitivity:5 %5 %
-
Product
ICP® Accelerometers With Excellent Thermal Stability
-
The single and triaxial ICP® accelerometers are designed with a low temperature coefficient, wide operating temperature range, and good broadband measurement resolution, making them ideal for any vibration measurement requiring tight control of amplitude sensitivity over a wide thermal gradient. To alleviate the effects of high frequency overloads caused by metal-to-metal inputs, a low pass filter has been incorporated in all models, ensuring accurate data in the frequency range of interest.
-
Product
Microphone Preamplifier
HT426E01
-
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA