Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@Lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road, Jiading District
Shanghai, 201802
China
-
Product
Plug and Switch Testing
-
Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right.
-
Product
LED Power Driver Tester
WT2080
-
WT2080 LED Power Driver Test Instrument is the comprehensive test instrument for LED drive power which is according to GB/T 24825-2009 and IEC 62384:2006. It can measure the following parameters: Input Characteristics Test (AC&DC), Output Characteristics Test (AC&DC), Output Start Characteristics Test (DC) and Harmonic Testing.
-
Product
MOS Transistor Selector
UI9610
-
MOS with superior performance has now been widely used in electronic ballasts, energy-saving lamps were. But power MOS test screening, matching problem. It is difficult due to a lack of corresponding inspection means that many enterprises do not have to engage seriously in quality control as well as the effect of product consistence and reliability. The equipment in a unique program designed to solve the power MOS test problem containing micro-processing, intelligent a few significant simple application.
-
Product
Insulation Resistance Tester
WB2681A
-
• Insulation test voltages: DC250V、DC500V、DC1000V • Range of open-circuit voltage: ±10% rated voltage • Testing time: 3~99 seconds or controlled manually
-
Product
TTC-1 Tracking Test Chamber
TTC-1
-
It is according to IEC60695 and IEC60112 (GB4207), the Tracking Test Chamber TTC-1 is intended for determining the degree of protection against formation of conducting paths in solid insulating materials, due to the electric stress and electrolytic contamination of the surface. This method simulates tracking currents on insulation material by providing drops between electrodes. During the process of normal use, insulating material may be exposed to moisture and dirt, if conductive, may cause stress and fire hazard.
-
Product
HID Ballast Tester
WT2000-HID
-
• Input Parameters Measurement: 1) Test voltage, current, power, power factor, power line frequency, total harmonic and 0~50 harmonic 2) Range of voltage and current basic wave frequency: 45Hz~65Hz 3) Range of narrow frequency: 45Hz~5kHz 4) Range of wide frequency: 45Hz~1MHz
-
Product
Salt Spray Test Machine
YWX/Q-010
-
The Salt Spray Test Machine/Chamber is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products. • The Salt Spray Test Machine is made of transparent materials so that the operator can see the tested sample in it and the spraying situation of the tested sample. • A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow. • Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement. • It meets the following standards: IEC60068-2-11 (GB/T2423.17), GB/T10125, ISO9227, ASTM-B117, GB/T2423-18, IEC 60068-2-52, ASTM-B368, MIL-STD-202, EIA-364-26, ASTM-B117, GJB150, DIN50021-75, ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc.
-
Product
Quick-Scan Spectrophotometer Colorimeter
LMS-5000
-
LMS-5000 Quick-Scan Spectrophotometer Colorimeter is a very widely applied single monochromators spectrophotometer with high accuracy. A typical measuring time during the spectral range from 380~800nm is less than 10 seconds. LMS-5000 used with right size integrating sphere and standard light source can be applied to do spectral measurement of LEDs, LED modules, CFL, Fluorescent Lamp, CCFL, HID lamps and other luminaries.
-
Product
Photometer and Colorimeter
-
Illuminance (lux), CCT, Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram
-
Product
Aging and Life Test Rack
SY2036
-
SY2036 Aging and life test rack is fully designed according to the IEC standard, and can also be designed based on the customer request. SY2036 can test LED, CFL, HID Indoor lamp and Outdoor lamp. Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option) • Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option) • Maximum power for EUT: 5KVA and 12A (Other power is option) • EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be designed according to customer request) • ON/OFF test: Can be set on the touch screen with program • Test number: 0~99999(Adjustable)
-
Product
Optical Path Converter
LS512A/LS512B
-
There are many LED manufactories using two integrating spheres and one spectrophotometer to do test. The previous testing way is: when you use big sphere to test, the customer need to connect the detector cable and optical fiber from the Spectrophotometer to the big sphere, after the calibrating and then you can do the test. When you use the small sphere, you need to take away the detector cable and optical fiber from the big sphere to the small sphere, then need to calibrate again. It is too troublesome to take out the detector cable and optical fiber between the big sphere and small sphere, and you need to calibrate again for every change. The frequent change will also shorten the life of the detector cable and optical fiber.
-
Product
Portable CCD Spectroradiometer
LMS-6000
-
The Portable CCD Colorimeter Spectroradiometer has the following versions which can measure different parameters: • LMS-6000: illuminance (lux), E(Fc), Ee(W/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000L: cd/m2, fL, Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000P: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio • LMS-6000S: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio, Rf and Rg according to TM-30 • LMS-6000F: LMS-6000 Parameters+Flicker test • LMS-6000B: LMS-6000 Parameters+Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002 • LMS-6000BF: LMS-6000 Parameters+Flicker test, Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002
-
Product
PWM Type AC Power Supply
LSP-5KVA
-
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is 0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%
-
Product
New Design 3m Electric Integrating Sphere
IS-3.0MA
-
It has all functions of IS-*MA Integrating Sphere with Holder Base.• Lisun engineers add the infrared anti-pinch device (the video please come to the “video” tab) and the cross laser positioning device in the integrating sphere.• Please refer to article The New Design 3m Electric Integrating Sphere for more information.















